9.13
Device User ID
Device User ID provides the user access to the writable memory area.
Up to 64 bytes data can be stored (The data still remains, even the camera power is off)
When the data is less than 64 bytes, please add 0x00 at the end of data.
9.14
Event Control (Only available with USB3 Vision protocol)
The camera can be send notification of event inside of the camera to host controller.
GenICamParameters
EventSelector
IEnumeration Type
Select Event Function
EventNotification
IEnumeration Type
Switch On / Off for Event function that was selected at “EventSelector”.
On: Event function On, Off: Event function Off
Please select the available event at “EventSelector” then select “On” at “EventNotification” then the event
function is enabled.
The event functions on the camera are as follows.
1) Event Exposure Start
Send notification as event when expose starts in the camera.
Event ID is 0x9002.
2) Event Exposure End
Send notification as event when expose finishes in the camera.
Event ID is 0x9001.
(*) The event occurrence frequently, the stream data transferring rate could be reduced because Event and