![background image](http://html1.mh-extra.com/html/omron/stc-mbcm200u3v/stc-mbcm200u3v_product-specifications-and-users-manual_742899024.webp)
No.13S076-08
24/62
STC-MBCM200U3V / STC-MCCM200U3V / STC-MBCM200U3V-NIR
STC-MBCM401U3V / STC-MCCM401U3V / STC-MBCM401U3V-NIR Product Specifications and Use’s Guide
Input Response Characteristics
The response characteristics of CAM_RESET (Reference1), General Purpose Input (Reference 2) are shown in
the following diagrams
The capable input trigger’s pulse width is
Positive Edge: more than Ts + Tf
Negative Edge: more than Td + Tr
Td
0.06
µ
seconds
Tr
0.07
µ
seconds
Ts
4.06
µ
seconds
Tf
3.90
µ
seconds
USER_INPUT
Camera internal
Internal V3.3V)
0V
Internal Voltage
IO_GND