No. 17S142-00
STC-HD853HDMI
Product specifications and User’s guide
60/81
Slave address for the ICs (8 bits) list
IC
Slave address
Descriptions
DSP
81
DSP data
EEPROM
61
Temporary EEPROM zone for DSP data of currently selected DSP Preset.
EEPROM
90
EEPROM zone for Preset0 DSP data
EEPROM
91
EEPROM zone for Preset1 DSP data
EEPROM
92
EEPROM zone for Preset2 DSP data
EEPROM
93
EEPROM zone for Preset3 DSP data
EEPROM
94
EEPROM zone for Preset4 DSP data
EEPROM
95
EEPROM zone for Preset5 DSP data
EEPROM
96
EEPROM zone for Preset6 DSP data
EEPROM
97
EEPROM zone for Preset7 DSP data
uCOM
21
uCOM data
EEPROM
41
EEPROM zone for uCOM data
Note: There is maximum number of writing to EEPROM of 1,000,000 times.
Error code list
If an error occurs, camera sends an error code with the following format:
The Command number of Error Message is FF (HEX). The Data length is 0002.
Error
Receiving data
Check sum error
02, FF, 00, 02, 03, 00, 04, 03
Command being transmitted does NOT exist or invalid
02, FF, 00, 02, 04, 00, 05, 03
Un-processed data remains in receiving buffer
02, FF, 00, 02, 05, 00, 06, 03
Time out error
02, FF, 00, 02, 06, 00, 07, 03
Over run error
02, FF, 00, 02, 08, 00, 09, 03
Framing error
02, FF, 00, 02, 09, 00, 0A, 03
Data length error (data length is too long)
02, FF, 00, 02, 0B, 00, 0C, 03
I2C communication error
02, FF, 00, 02, 10, 00, 11, 03
Note.1: The camera disregards data, which is not start with SOF.
Note.2: The time out error is occurred when does not receive next data three seconds after receive data.