No. 17S142-00
STC-HD853HDMI
Product specifications and User’s guide
9/81
Precautions
(*1) The sensitivity is measuring the luminance when white level achieved 100 % in below conditions.
(*2) When selecting “Auto” at video output, video output format is selecting automatically based on connected
monitor supported format.
e.g. If the monitor supports up to 2160P30, video output format of camera selects 2160P30 automatically.
Camera Setting
Environment
Parameter
Setting
Parameter
Setting
Gain Up
0 dB
Light Source
Light Box (White)
AGC
Off
Color temperature 5,100K
White Balance
Optimum
Lens
Electrical Shutter 1/30 seconds
F on Lens
F5.6
Black Level
Optimum
Target Luminance IM-600 (Topcon)
Gamma
Factory Setting