Chapter 3: Installation
Recommended Power Supplies
Table 3-2. Recommended Power Supplies
Vendor Name
Model
Ratings
Mount
OMRON
S8FS-G15024C
24 VDC, 6.5 A, 150 W
Side/Bottom
OMRON
S8FS-G15024CD
24 VDC, 6.5 A, 150 W
DIN-Rail Mount
Recommended UPS Units
If power interruption is a concern, a UPS is recommended. The following table lists two recom-
mended UPS units.
Table 3-3. Recommended UPS Units
Vendor Name
Model
Ratings
OMRON
S8BA-24D24D360LF
24 VDC, 15 A, 360 W
OMRON
S8BA-24D24D480LF
24 VDC, 20 A, 480 W
Installing 24 VDC Connector
In order to maintain compliance with EN standards, DC power must be delivered over a shiel-
ded cable, with the shield connected to the frame ground at both ends of the cable. Conductors
should be 1.5 to 1.85 mm
2
(16 to 14 AWG). The maximum length for the 24 VDC cable is 10
meters.
Use the supplied connector to connect the user-supplied 24 VDC power supply to the SmartVi-
sion MX.
1. Locate the 24 VDC connector that is shipped with the SmartVision MX industrial PC.
See the following figure.
2. Strip 7 mm of insulation from the end of the wire that connects to the positive output of
the 24 VDC supply.
3. Insert the stripped end of the wire into the opening on the right side of the connector.
4. Using a small, flat-blade screwdriver, tighten the screw clamp on the connector.
5. Inspect the connection to ensure that the clamp is on the wire, not on the insulation.
6. Gently pull on the wire to confirm that it is securely attached to the connector.
7. Repeat this process to connect the wire from the negative side of the power supply to
the center of the connector.
8. Repeat this process to connect the braided shield to the left side of the connector.
9. Plug the connector into the SmartVision MX industrial PC.
14362-000 Rev. D
SmartVision MX User's Guide
19