S8VS

2

Ordering Information

List of Models

Note:

For details on normal stock models, contact your nearest OMRON representative.

Models without Indication Monitor (Standard Models)

*1.

The output capacity of the S8VS-01505 is 10 W.

*2.

The output capacity of the S8VS-03005 is 20 W.

*3.

The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).

Models with Indication Monitor (Maintenance Forecast Monitor)

*1.

The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).

*2.

In the 

Alarm output 

column, “sinking” indicates an emitter COM and “sourcing” indicates a collector COM.

Models with Indication Monitor (Total Run Time Monitor)

*1.

The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).

*2.

In the 

Alarm output

 column, “sinking” indicates an emitter COM and “sourcing” indicates a collector COM.

Note:

 Refer to pages 24 to 25 for the options that available.

Power ratings

Input voltage

Output voltage

Output current

UL Class 2 

Output standards

Model number

(screw terminal block)

Model number

(screwless terminal block)

15 W

100 to 240 VAC

(allowable range: 

85 to 264 VAC or 

80 to 370 VDC 

*

3

)

5 V

2.0 A

Yes

S8VS-01505 

*

1

---

12 V

1.2 A

Yes

S8VS-01512 

24 V

0.65 A

Yes

S8VS-01524

30 W

5 V

4.0 A

Yes

S8VS-03005 

*

2

12 V

2.5 A

Yes

S8VS-03012

24 V

1.3 A

Yes

S8VS-03024

60 W

24 V

2.5 A

Yes

S8VS-06024

S8VS-06024-F 

90 W

3.75 A

---

S8VS-09024

S8VS-09024-F 

Yes

S8VS-09024S S8VS-09024S-F 

120 W

5 A

---

S8VS-12024

S8VS-12024-F 

180 W

7.5 A

---

S8VS-18024

S8VS-18024-F 

240 W

10 A

---

S8VS-24024

S8VS-24024-F 

480 W

100 to 240 VAC

20 A

Peak current 30 A

(200 VAC)

---

S8VS-48024

S8VS-48024-F 

Power ratings

Input voltage

Output 

voltage

Output current

Alarm 

output 

*

2

UL Class 2 

Output standards

Model number

(screw terminal block)

Model number

(screwless terminal block)

60 W

100 to 240 

VAC

(allowable 

range: 85 to 

264 VAC or 80 

to 370 VDC 

*

1

)

24 V

2.5 A

---

Yes

S8VS-06024A

S8VS-06024A-F 

90 W

3.75 A

Sinking

---

S8VS-09024A

S8VS-09024A-F 

Sinking

Yes

S8VS-09024AS

S8VS-09024AS-F 

Sourcing

---

S8VS-09024AP

S8VS-09024AP-F 

Sourcing

Yes

S8VS-09024APS S8VS-09024APS-F 

120 W

5 A

Sinking

---

S8VS-12024A

S8VS-12024A-F 

Sourcing

---

S8VS-12024AP

S8VS-12024AP-F 

180 W

7.5 A

Sinking

---

S8VS-18024A

S8VS-18024A-F 

Sourcing

---

S8VS-18024AP

S8VS-18024AP-F 

240 W

10 A

Sinking

---

S8VS-24024A

S8VS-24024A-F 

Sourcing

---

S8VS-24024AP

S8VS-24024AP-F 

480 W

100 to 240 

VAC

20 A

Peak current 30 A

(200 VAC)

Sinking/

sourcing

---

S8VS-48024A

S8VS-48024A-F 

Power ratings

Input voltage

Output 

voltage

Output current

Alarm 

output 

*

2

UL Class 2 

Output standards

Model number

(screw terminal block)

Model number

(screwless terminal block)

60 W

100 to 240 

VAC

(allowable 

range: 85 to 

264 VAC or 80 

to 370 VDC) 

*

1

24 V

2.5 A

---

Yes

S8VS-06024B

S8VS-06024B-F 

90 W

3.75 A

---

---

S8VS-09024BE S8VS-09024BE-F 

---

Yes

S8VS-09024BES S8VS-09024BES-F 

Sinking

---

S8VS-09024B

S8VS-09024B-F 

Sinking

Yes

S8VS-09024BS S8VS-09024BS-F 

Sourcing

---

S8VS-09024BP

S8VS-09024BP-F 

Sourcing

Yes

S8VS-09024BPS S8VS-09024BPS-F 

120 W

5 A

---

---

S8VS-12024BE S8VS-12024BE-F 

Sinking

---

S8VS-12024B

S8VS-12024B-F 

Sourcing

---

S8VS-12024BP

S8VS-12024BP-F 

180 W

7.5 A

---

---

S8VS-18024BE S8VS-18024BE-F 

Sinking

---

S8VS-18024B

S8VS-18024B-F 

Sourcing

---

S8VS-18024BP

S8VS-18024BP-F 

240 W

10 A

---

---

S8VS-24024BE S8VS-24024BE-F 

Sinking

---

S8VS-24024B

S8VS-24024B-F 

Sourcing

---

S8VS-24024BP

S8VS-24024BP-F 

480 W

100 to 240 

VAC

20 A

Peak current 30 A

(200 VAC)

Sinking/

sourcing

---

S8VS-48024B

S8VS-48024B-F 

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Summary of Contents for S8VS-015 Series

Page 1: ...d Safety Precautions on page 32 Recommended Noise Filter Noise filter S8V NF For more information refer to S8V NF Noise Filter Data Sheet Cat No T212 E1 1 2 3 4 5 6 S8VS 1 Power Ratings 015 15 W 030 3...

Page 2: ...t 30 A 200 VAC S8VS 48024 S8VS 48024 F Power ratings Input voltage Output voltage Output current Alarm output 2 UL Class 2 Output standards Model number screw terminal block Model number screwless ter...

Page 3: ...typical 360 ms typical 380 ms typical 400 ms typical Output hold time at rated I O 2 With 100 VAC input 39 ms typical 27 ms typical 28 ms typical 31 ms typical 22 ms typical 31 ms typical With 200 VAC...

Page 4: ...ypical 33 ms typical With 200 VAC input 158 ms typical 154 ms typical Additional functions Overload protection 2 105 to 160 of rated load current 101 to 110 of rated load current for the S8VS 09024 S...

Page 5: ...o 110 of rated load current for the S8VS 09024 S inverted L voltage drop intermittent automatic reset Overvoltage protection 2 4 Yes Output voltage indication 5 No Yes selectable 6 Output current indi...

Page 6: ...Total run time monitor indication 5 No Yes selectable No Yes selectable Total run time monitor output 5 No Yes transistor output 30 VDC max 50 mA max 9 No Yes transistor output 30 VDC max 50 mA max 9...

Page 7: ...ble No Yes selectable Undervoltage alarm output terminals No Yes transistor output 30 VDC max 50 mA max 9 No Yes transistor output 30 VDC max 50 mA max 9 Parallel operation No However backup operation...

Page 8: ...S8VS 015 15 W Voltage detection circuit Photocoupler Rectifier smoothing circuit AC L INPUT AC N Drive control circuit V V DC output Fuse 4 0 A Undervoltage indicator Overvoltage detection circuit Noi...

Page 9: ...ifier S8VS 06024A 60 W S8VS 06024B 60 W S8VS 06024 60 W AC L INPUT AC N V V DC OUTPUT Fuse 6 3 A Rectifier Voltage detection circuit Photocoupler Rectifier smoothing circuit Noise filter Drive control...

Page 10: ...uit Overvoltage detection circuit Current detection circuit S8VS 09024A 90 W S8VS 09024B 90 W S8VS 09024BE 90 W S8VS 09024A S 90 W S8VS 09024B S 90 W S8VS 09024BES 90 W S8VS 09024 90 W S8VS 09024S 90...

Page 11: ...ing circuit V V DC OUTPUT Alarm DC Low S8VS 12024A 120 W S8VS 12024B 120 W S8VS 12024BE 120 W S8VS 12024 120 W Photocoupler Rectifier smoothing circuit INPUT V V DC OUTPUT AC L AC N Fuse 5 0 A Rectifi...

Page 12: ...peration circuit Alarm DC Low S8VS 18024A 180 W S8VS 18024B 180 W S8VS 18024BE 180 W S8VS 18024 180 W Photocoupler INPUT Rectifier smoothing circuit V V DC OUTPUT Fuse 6 3 A AC L AC N Voltage detectio...

Page 13: ...V V V V DC OUTPUT S8VS 24024A 240 W S8VS 24024B 240 W S8VS 24024BE 240 W S8VS 24024 240 W DC OUTPUT INPUT Inrush current protection circuit Harmonic current suppression circuit Power factor improveme...

Page 14: ...0 W 90 120 180 and 240 W Sinking type 11 12 13 Undervoltage Undervoltage Maintenance forecast time or total run time Maintenance forecast time or total run time Common 90 120 180 and 240 W Sourcing ty...

Page 15: ...al 2 3 DC Output terminals V V Connect the load lines to these terminals 4 Output indicator DC ON Green Lights while a direct current DC output is ON 5 Undervoltage indicator DC LOW Red Lights when a...

Page 16: ...DC output is ON 5 Output voltage adjuster V ADJ Use to adjust the voltage 3 6 Main display Red 4 Indicates the measurement or set value 7 Operation indicator Orange 4 V Lights up when the output volt...

Page 17: ...on of total run time monitor Blinks during setup of total run time monitor S8VS 48024B 8 Mode Key 3 Use the Mode Key to change the indicated parameter or reset the peak hold current value 9 Up Key 3 U...

Page 18: ...ced air cooling 3 When using a 480 W model at an input voltage of 95 VAC or less derate the load by at least 80 4 DC Inputs If the input voltage is less than 100 VDC reduce the load given in the above...

Page 19: ...our boost current conditions Time that the boost current flows t1 10 s The boost current Ip Maximum boost current The average output current Iave Rated output current The time ratio of the boost curre...

Page 20: ...t terminal DC LOW Example Outputting an Alarm When the Voltage Output by the S8VS 09024A Drops to the Set Value 19 0 V or Lower Note 1 Operation begins after about three seconds since the AC power is...

Page 21: ...90 W S8VS 09024S 90 W S8VS 12024 120 W S8VS 09024A 90 W S8VS 09024A S 90 W S8VS 12024A 120 W S8VS 09024B 90 W S8VS 09024B S 90 W S8VS 12024B 120 W S8VS 09024BE 90 W S8VS 09024BES 90 W S8VS 12024BE 120...

Page 22: ...Stopper 35 4 S8VS 06024 F 60 W S8VS 06024A F 60 W S8VS 06024B F 60 W Rail Stopper 10 97 3 50 1 1 10 max 110 3 115 3 35 4 115 1 4 5 Sliding 15 max S8VS 09024 F 90 W S8VS 09024S F 90 W S8VS 12024 F 120...

Page 23: ...150 1 127 2 1 122 2 Rail Stopper Rail Stopper 96 3 35 4 115 1 S8VS 48024 F 480 W S8VS 48024A F 480 W S8VS 48024B F 480 W Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com...

Page 24: ...10 M4 spring washer M4 8 pan head screw S8VS Input side Output side 15W S82Y VS C2P S 30W S82Y VS C2P S 60W S82Y VS C3P S82Y VS C2P M 90W S82Y VS C3P S82Y VS C2P M 120W S82Y VS C3P S82Y VS C2P M 180W...

Page 25: ...1 Left side mounting Right side mounting t 2 0 89 78 55 0 1 47 5 4 5 dia 0 1 80 60 0 1 Left side mounting Right side mounting also possible 60 0 1 55 0 1 13 80 78 114 4 5 dia 0 1 t 2 0 60 Left side m...

Page 26: ...s recorded and displayed Total run time monitor Output voltage Voltage output by Power Supply is monitored and displayed Output current Current output by Power Supply is monitored and displayed Peak h...

Page 27: ...econds Peak hold current will be displayed 2 seconds after it is reset Key Press 3 seconds or more Operation Mode Output current Peak hold current Maintenance forecast monitor Undervoltage alarm Under...

Page 28: ...the set value of the corresponding point The set value must return to the shipment setting Shipment setting or value set in the setting mode again e02 Memory error of alarm set value of maintenance f...

Page 29: ...forecast output terminal Yrs will turn OFF to indicate the need for maintenance The transistor turns OFF when the maintenance forecast time is reached i e there will be no continuity at the maintenan...

Page 30: ...pped with output 4 The accuracy of the maintenance forecast function may be adversely affected by applications in which the AC input is frequently turned ON OFF Reference Values 15 W to 480 W Models N...

Page 31: ...gher than the value displayed for the total run time Time Chart Setting is possible for the following models only S8VS 09024B S8VS 09024BE S8VS 12024B S8VS 12024BE S8VS 18024B S8VS 18024BE S8VS 24024B...

Page 32: ...pletely A protective earthing terminal stipulated in safety standards is used Electric shock or malfunction may occur if the ground is not connected completely Minor fire may possibly occur Ensure tha...

Page 33: ...cast monitor output Yrs or total run time monitor output kh is correctly functioning by the following procedure 1 Select the operation mode 2 Check that the output Yrs kh is turned ON with continuity...

Page 34: ...egative Outputs The outputs are floating outputs i e the primary circuits and secondary circuits are separated You can therefore make positive and negative outputs by using two Power Supplies You can...

Page 35: ...he load is in overload status or is short circuited Remove wires to load when checking Checking overvoltage or internal protection Turn the power supply OFF once and leave it OFF for at least 3 minute...

Page 36: ...Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Ar...

Page 37: ...ide applicable third party certification documents identifying ratings and limitations of use which apply to the Product This information by itself is not sufficient for a complete determination of th...

Page 38: ...5037 2222 Fax 86 21 5037 2200 Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded fro...

Reviews: