background image

S8EA

3

Ratings, Characteristics, and Functions

*1.

Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal 

temperature of the Power Supply may result in ignition or burning.

*2.

For details, refer to 

Output Voltage Adjuster (V. ADJ)

 on page 16.

*3.

Specified for the rated input voltage (100 VAC) and a 100% load. 

The measurement method is based on JEITA standard RC-9131B. 

For details, refer to 

Ripple Noise Voltage

 on page 17.

*4.

To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON.

*5.

The weight is for an open-frame model.

*6.

The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 120 VAC (85 to 132 VAC).

*7.

Class B compliance was met with an aluminum plate placed under the Power Supply.

*8.

Excluding models with low leakage current.

Power rating

50 W

75 W

Item

Output voltage

5 V

12 V

24 V

5 V

12 V

24 V

Efficiency (Typ.)

100 VAC input

78%

84%

85%

83%

85%

88%

Input

Voltage

*

1

100 to 120 VAC (allowable voltage: 85 to 132 VAC, 120 to 175 VDC

*

6)

Frequency

*

1

50/60 Hz (47 to 63 Hz)

Current (Typ.)

100 VAC input

1.3 A

1.4 A

1.6 A

Power factor

--- 

Harmonic current emissions

---

Leakage current 

100 VAC input

0.5 mA max. (model with low leakage current: 0.1 mA max.)

Inrush current 

100 VAC input

17.5 A max.

Output 

Voltage adjustment range

*

2

±10% (with V. ADJ)

Ripple

*

3

150 mV max.

240 mV max.

480 mV max.

150 mV max.

240 mV max.

480 mV max.

Input variation influence

±1% max. (with 100 VAC input at 100% load)

±1% max. (with 100 VAC input at 100% load)

Load variation influence

2% max.

1.5% max.

2% max.

1.5% max.

Temperature variation influence

0.05%/°C max.

Startup time (Typ.)

100 VAC input

400 ms

550 ms

Hold time (Typ.)

100 VAC input

20 ms

25 ms

Additional 
functions

Overload protection 

105% to 160% of rated load current, voltage drop, intermittent, automatic reset

Overvoltage protection

*

4

Yes (at 130% or higher of rated output)

Series operation

Yes (For up to two Power Supplies; external diodes required.)

Parallel operation

No

Other

Ambient operating temperature

10 to 60°C (Derating is required according to the temperature.) (with no icing or condensation)

Storage temperature

25 to 75°C

Ambient operating humidity

25% to 85% (Storage humidity: 25% to 90%)

Dielectric strength

3.0 kVAC for 1 min. (between all inputs and outputs; Cutoff current: 10 mA)
2.0 kVAC for 1 min. (between all inputs and PE; Cutoff current: 10 mA)
1.0 kVAC for 1 min. (between all outputs and PE; Cutoff current: 20 mA)

Insulation resistance

100 M

Ω

 min. (between all outputs and all inputs/PE)

Vibration resistance

10 to 55 Hz, 19.6 m/s

2

 (2 G) for 1 h each in X, Y, and Z directions

Shock resistance

196.1 m/s

2

, 3 times each in ±X, ±Y, ±Z directions

Conducted emissions 

Conforms to EN 55011 Group 1 Class B 

*

*

8

Radiated emissions

Conforms to EN 55011 Group 1 Class B 

*

*

8

Approved standards 

UL UR: UL 60950-1 (Recognition)
cUR: CSA C22.2 No. 60950-1
EN: EN 50178 and EN 60950-1

SEMI

---

Weight

 

*

5

140 g max. (without chassis and cover)

190 g max. (without chassis and cover)

Summary of Contents for S8EA Series

Page 1: ...or 100 to 120 VAC Operation is possible at an ambient temperature of 60 C at 60 load which is ideal for compact devices Open frame models with standard installation Approved standards UL60950 1 cUR CS...

Page 2: ...Boost current Model 50 W 5 V 10 A S8EA N05005L 12 V 4 3 A S8EA N05012L 24 V 2 5 A 3 8 A S8EA BN05024L 75 W 5 V 15 A S8EA N07505L 12 V 6 3 A S8EA N07512L 24 V 3 2 A 4 8 A S8EA BN07524L 100 W 5 V 20 A...

Page 3: ...240 mV max 480 mV max 150 mV max 240 mV max 480 mV max Input variation influence 1 max with 100 VAC input at 100 load 1 max with 100 VAC input at 100 load Load variation influence 2 max 1 5 max 2 max...

Page 4: ...ith 85 to 132 VAC input at 100 load Load variation influence 2 max 1 5 max 2 max 1 5 max Temperature variation influence 0 05 C max Startup time Typ 100 VAC input 550 ms 350 ms Hold time Typ 100 VAC i...

Page 5: ...rol circuit V V DC OUTPUT Overcurrent detection circuit Noise filter Fuse AC L INPUT AC N Rectifier Smoothing circuit Rectifier smoothing circuit S8EA N050 3 15 A S8EA N075 4 0 A S8EA N100 5 0 A S8EA...

Page 6: ...2Y EX03HO 01 OK Output side Output side S82Y EX04HO 01 OK Output side Output side S82Y EX05HO 01 OK OK OK OK Input side S82Y EX01HI 10 10 OK Output side Output common S82Y EX01HO 10 OK Output side S82...

Page 7: ...ed 500 S82Y EX04HO Housing Model VHR 6N Manufacturer J S T Mfg Co Ltd Pins Model SVH 21T P1 1 Manufacturer J S T Mfg Co Ltd Pin Wire AWG Color Length L mm 1 UL1015 18 Red 500 2 UL1015 18 Red 500 3 UL1...

Page 8: ...0 80 120 100 80 60 40 20 0 Mounting method A Mounting methods B to D Mounting method E Ambient temperature C A Load rate 10 0 10 20 30 40 50 60 70 80 120 100 80 60 40 20 0 Mounting method A Mounting m...

Page 9: ...80 60 40 20 0 Mounting method A Mounting methods B and C Mounting methods D and E Ambient temperature C A Load rate 10 0 10 20 30 40 50 60 70 80 120 100 80 60 40 20 0 Mounting method A Mounting metho...

Page 10: ...ut the output voltage is shut OFF preventing damage to the load due to overvoltage To reset the protection turn OFF the input power for three minutes or longer and then turn it back ON Reference Graph...

Page 11: ...ur 3 5 dia mounting holes CN1 CN51 3 5 max height with components mounted 23 1 Output Output V ADJ Input N Input L S8EA N050 50 W 150 1 5 5 140 0 5 40 0 5 50 1 VR51 Four 3 5 dia mounting holes CN1 CN5...

Page 12: ...oles 30 1 3 5 max height with components mounted Output Output V ADJ Input N Input L S8EA N100 100 W 160 1 65 0 5 75 1 5 5 150 0 5 CN51 VR51 CN52 CN1 33 5 1 3 5 max height with components mounted Four...

Page 13: ...CN51 CN1 15 3 5 10 36 1 6 150 0 5 162 1 Two M3 mounting holes 3 5 dia hole Input N Input L Output V ADJ Output S8EA N050 L 50 W 4 5 30 60 1 20 0 5 20 10 Two 4 5 dia holes 169 0 5 5 5 40 0 5 VR51 CN1...

Page 14: ...5 45 1 15 20 Two M4 mounting holes 4 5 dia hole Input N Input L Output V ADJ Output S8EA N100 L 100 W Two 4 5 dia holes 4 5 dia hole 15 25 35 0 5 55 0 5 6 176 0 5 42 4 5 85 1 CN51 VR51 CN1 Four M4 mou...

Page 15: ...the terminal rating is used Use wiring materials with a UL recognized temperature of 60 C min or 60 C 75 C min Use wiring materials with copper conductors Refer to Input and Output Connectors on page...

Page 16: ...k the output voltage of the Power Supply and be sure that the load is not destroyed Series Operation Two Power Supplies can be connected in series The voltage output can be accomplished with two Power...

Page 17: ...al protection Turn the power supply OFF once and leave it OFF for at least 3 minutes for S8EA series Then turn it ON again to see if this clears the condition Power Boost Function Do not allow the boo...

Page 18: ...list of all possible uses of the products nor is it intended to imply that the uses listed may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical i...

Page 19: ...02 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron com To...

Reviews: