background image

S8VK-G

22

Period and Terms of Warranty

Warranty Period

The product warranty is valid for a period of three years from the date 
of shipment from the factory.

Terms of Warranty

The warranty is valid only for the following operating conditions.

1.

Average ambient operating temperature of the product: 40°C max.

2.

Average load rate: 80% max.

3.

Mounting method: Standard mounting

*

The maximum ratings must be within the derating curve.

If the product fails for reasons attributable to OMRON within the 
above warranty period, OMRON will repair or replace the faulty part 
of the product at the place of purchase or the place where the product 
delivered without charge.
This warranty does not cover the following types of failures.

Recommended Replacement Periods and Periodic Replacement for 
Preventive Maintenance

The recommended replacement period for preventive maintenance is 
greatly influenced by the application environment of the product. As a 
guideline, the recommended replacement period is 7 to 10 years.*
To prevent failures or accidents that can be caused by using a product 
beyond its service live, we recommend that you replace the product 
as early as possible within the recommended replacement period.
However, bear in mind that the recommended replacement period is 
for reference only and does not guarantee the life of the product.

Many electronic components are used in the product and the product 
depends on the correct operation of these components to achieve the 
original product functions and performance.
However, the influence of the ambient temperature on aluminum 
electrolytic capacitors is large, and the service life is reduced by half 
for each 10°C rise in temperature (Arrhenius law).
When the capacity reduction life of the electrolytic capacitor is 
reached, the product failures or accidents may occur.
We therefore recommend that you replace the product periodically to 
minimize product failures or accidents in advance.

*

The recommended replacement period applies under the following 
conditions: rated input voltage, load rate of 50% max., ambient 
temperature of 40°C max., and the standard mounting method.

This product model is designed with a service life of 10 years 
minimum under the above conditions.

(1)

Failures that result from handling or operation of the product under conditions or in environments that are not given in this document and 
not given in any other specifications exchanged between OMRON and the customer

(2)

Failures that originate in causes other than the delivered product itself

(3)

Failures caused by disassembly, modification, or repair of the product by anyone other than OMRON

(4)

Failures caused by applications or uses for which the product was not originally intended

(5)

Failures caused by factors that could not be anticipated with the scientific or technical knowledge available when the product was shipped

(6)

Failures caused by other causes for which OMRON is not responsible, such as natural disasters and other acts of God
This warranty is limited to the individual product that was delivered and does not cover any secondary, subsequent, or related damages.

Summary of Contents for S82Y-VK10S

Page 1: ...Wide operation temperature range 40 to 70 C Power Boost function at 120 Safety standards UL508 60950 1 CSA C22 2 No 107 1 60950 1 EN50178 EN60950 1 Lloyd s standards EN60204 1 PELV Safety of Power Tr...

Page 2: ...3 6 A S8VK G01505 12 V 1 2 A 1 44 A S8VK G01512 24 V 0 65 A 0 78 A S8VK G01524 30 W 5 V 5 A 6 A S8VK G03005 12 V 2 5 A 3 A S8VK G03012 24 V 1 3 A 1 56 A S8VK G03024 60 W 12 V 4 5 A 5 4 A S8VK G06012...

Page 3: ...0 65 A 5 A 2 5 A 1 3 A Boost current 3 6 A 1 44 A 0 78 A 6 A 3 A 1 56 A Voltage adjustment range 3 10 to 15 with V ADJ guaranteed Ripple Noise voltage 4 100 to 240 VAC input 100 load 6 60 mVp p max a...

Page 4: ...32 A typ 32 A typ Output Rated output current 4 5 A 2 5 A 5 A Boost current 5 4 A 3 A 6 A Voltage adjustment range 3 10 to 15 with V ADJ guaranteed Ripple Noise voltage 4 100 to 240 VAC input 100 load...

Page 5: ...2 A typ 32 A typ Output Rated output current 10 A 5 A 20 A 10 A Boost current 12 A 6 A 24 A 12 A Voltage adjustment range 3 10 to 15 with V ADJ guaranteed Ripple Noise voltage 4 100 to 240 VAC input 1...

Page 6: ...hotocoupler Rectifier smoothing circuit AC L INPUT AC N Drive control circuit Fuse 250 VAC 4 0 A HBC Overvoltage detection circuit Noise filter Inrush current protection Rectifier Smoothing circuit Ov...

Page 7: ...t Harmonic current suppression circuit Power factor improvement Drive control circuit Rectifier smoothing circuit Voltage detection circuit Overvoltage detection circuit V V V V V DC OUTPUT Overcurren...

Page 8: ...K G015 S8VK G030 S8VK G060 120 W Models 240 W Models 480 W Models S8VK G12024 S8VK G240 S8VK G480 No Name Function 1 Input terminals L N Connect the input lines to these terminals 1 2 Protective Earth...

Page 9: ...s than 90 VAC the derating is 2 5 V 2 For a DC power input reduce the load given in the above derating curve by multiplying the following coefficients S8VK G12024 0 9 3 This is the guaranteed value fo...

Page 10: ...excessive voltage even if the feedback circuit in the Power Supply fails If an excessive voltage that is approximately 130 of the rated voltage or more is output the output voltage is shut OFF Reset t...

Page 11: ...rcuit breaker should be connected on N input line like the following Reference Value Reliability MTBF Value Single phase model 15 W 600 000 hrs 30 W 580 000 hrs 60 W 590 000 hrs 120 W 450 000 hrs 240...

Page 12: ...22 5 1 Rail Stopper 86 75 4 90 1 4 7 Sliding 10 max 90 1 S8VK G015 15 W 5 1 3 5 7 62 16 32 1 Rail Stopper 86 75 4 90 1 4 7 Sliding 10 max 90 1 S8VK G030 30 W 110 1 106 5 7 62 16 32 1 Rail Stopper 75 4...

Page 13: ...8 Rail Stopper 4 7 Sliding 7 5 max S8VK G12024 120 W 1 140 145 6 10 4 6 35 6 35 19 8 Rail Stopper 150 1 4 7 Sliding 7 5max 104 6 60 1 125 1 S8VK G240 240 W 10 4 140 145 6 1 6 35 6 35 30 25 19 8 Rail...

Page 14: ...f there is a possibility that the Unit will be subject to vibration or shock use a steel DIN Rail Otherwise metallic filings may result from aluminum abrasion 4 5 15 25 25 10 10 1 000 500 25 25 15 5 3...

Page 15: ...r 30 and 60 W models S82Y VS10S Side mounting bracket for 120 W models S82Y VK10S Side mounting bracket for 240 W models S82Y VK20S Type Model Dimensions Appearance Front mounting bracket For 15 30 an...

Page 16: ...bracket For 120 W models S82Y VK10S Side mounting bracket For 240 W models S82Y VK20S 35 64 t 2 0 80 60 0 1 55 0 1 13 4 5 dia 0 1 Left side mounting Right side mounting 140 0 1 50 0 1 15 5 0 1 150 12...

Page 17: ...r Do not allow any pieces of metal or conductors or any clippings or cuttings resulting from installation work to enter the Product CAUTION Indicates a potentially hazardous situation which if not avo...

Page 18: ...0 5 to 2 5 mm2 AWG14 to 12 2 5 to 4 mm2 2 5 to 4 mm2 8 to 10 mm S8VK G01512 AWG22 to 12 0 35 to 4 mm2 0 35 to 2 5 mm2 S8VK G01524 AWG24 to 12 0 25 to 4 mm2 0 25 to 2 5 mm2 S8VK G03005 AWG24 to 12 0 2...

Page 19: ...ng horizontally always place the side with the label facing upward DIN Rail Mounting To mount the Block on a DIN Rail hook portion A of the Block onto the rail and press the Block in direction B To di...

Page 20: ...5 to 40 C 2 Up to two of the same model can be connected in parallel 3 Adjust the output voltage difference of each Power Supply to 50 mV or less using the output voltage adjuster V ADJ 4 There is no...

Page 21: ...unt of surge voltage such as a lightening surge occurs while turning ON the power supply In case there is no output voltage please check the following points before contacting us Checking overload pro...

Page 22: ...nents to achieve the original product functions and performance However the influence of the ambient temperature on aluminum electrolytic capacitors is large and the service life is reduced by half fo...

Page 23: ...CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Pr...

Page 24: ...omron com Kyoto JAPAN OMRON ASIA PACIFIC PTE LTD No 438A Alexandra Road 05 05 08 Lobby 2 Alexandra Technopark Singapore 119967 Tel 65 6835 3011 Fax 65 6835 2711 OMRON CHINA CO LTD Room 2211 Bank of Ch...

Reviews: