background image

S8VK-G

17

Safety Precautions

Warning Indications

Meaning of Product Safety Symbols

 

!

CAUTION

Minor electric shock, fire, or Product failure may 
occasionally occur. Do not disassemble, modify, or 
repair the Product or touch the interior of the 
Product.

Minor burns may occasionally occur. Do not touch 
the Product while power is being supplied or 
immediately after power is turned OFF.

Fire may occasionally occur. Tighten terminal screws 
to the specified torque (0.5 to 0.6 N·m).

Minor injury due to electric shock may occasionally 
occur. Do not touch the terminals while power is 
being supplied. Always close the terminal cover after 
wiring.

Minor electric shock, fire, or Product failure may 
occasionally occur. Do not allow any pieces of metal 
or conductors or any clippings or cuttings resulting 
from installation work to enter the Product.

CAUTION

Indicates a potentially hazardous 
situation which, if not avoided, may 
result in minor or moderate injury or in 
property damage.

Precautions for 

Safe Use

Supplementary comments on what to 
do or avoid doing, to use the product 
safely.

Precautions for 

Correct Use

Supplementary comments on what to 
do or avoid doing, to prevent failure to 
operate, malfunction or undesirable 
effect on product performance.

Used to warn of the risk of electric shock under 
specific conditions.

Used to warn of the risk of minor injury caused by 
high temperatures.

Used for general mandatory action precautions 
for which there is no specified symbol.

Use to indicate prohibition when there is a risk of 
minor injury from electrical shock or other source 
if the product is disassembled. 

Summary of Contents for S82Y-VK10S

Page 1: ...Wide operation temperature range 40 to 70 C Power Boost function at 120 Safety standards UL508 60950 1 CSA C22 2 No 107 1 60950 1 EN50178 EN60950 1 Lloyd s standards EN60204 1 PELV Safety of Power Tr...

Page 2: ...3 6 A S8VK G01505 12 V 1 2 A 1 44 A S8VK G01512 24 V 0 65 A 0 78 A S8VK G01524 30 W 5 V 5 A 6 A S8VK G03005 12 V 2 5 A 3 A S8VK G03012 24 V 1 3 A 1 56 A S8VK G03024 60 W 12 V 4 5 A 5 4 A S8VK G06012...

Page 3: ...0 65 A 5 A 2 5 A 1 3 A Boost current 3 6 A 1 44 A 0 78 A 6 A 3 A 1 56 A Voltage adjustment range 3 10 to 15 with V ADJ guaranteed Ripple Noise voltage 4 100 to 240 VAC input 100 load 6 60 mVp p max a...

Page 4: ...32 A typ 32 A typ Output Rated output current 4 5 A 2 5 A 5 A Boost current 5 4 A 3 A 6 A Voltage adjustment range 3 10 to 15 with V ADJ guaranteed Ripple Noise voltage 4 100 to 240 VAC input 100 load...

Page 5: ...2 A typ 32 A typ Output Rated output current 10 A 5 A 20 A 10 A Boost current 12 A 6 A 24 A 12 A Voltage adjustment range 3 10 to 15 with V ADJ guaranteed Ripple Noise voltage 4 100 to 240 VAC input 1...

Page 6: ...hotocoupler Rectifier smoothing circuit AC L INPUT AC N Drive control circuit Fuse 250 VAC 4 0 A HBC Overvoltage detection circuit Noise filter Inrush current protection Rectifier Smoothing circuit Ov...

Page 7: ...t Harmonic current suppression circuit Power factor improvement Drive control circuit Rectifier smoothing circuit Voltage detection circuit Overvoltage detection circuit V V V V V DC OUTPUT Overcurren...

Page 8: ...K G015 S8VK G030 S8VK G060 120 W Models 240 W Models 480 W Models S8VK G12024 S8VK G240 S8VK G480 No Name Function 1 Input terminals L N Connect the input lines to these terminals 1 2 Protective Earth...

Page 9: ...s than 90 VAC the derating is 2 5 V 2 For a DC power input reduce the load given in the above derating curve by multiplying the following coefficients S8VK G12024 0 9 3 This is the guaranteed value fo...

Page 10: ...excessive voltage even if the feedback circuit in the Power Supply fails If an excessive voltage that is approximately 130 of the rated voltage or more is output the output voltage is shut OFF Reset t...

Page 11: ...rcuit breaker should be connected on N input line like the following Reference Value Reliability MTBF Value Single phase model 15 W 600 000 hrs 30 W 580 000 hrs 60 W 590 000 hrs 120 W 450 000 hrs 240...

Page 12: ...22 5 1 Rail Stopper 86 75 4 90 1 4 7 Sliding 10 max 90 1 S8VK G015 15 W 5 1 3 5 7 62 16 32 1 Rail Stopper 86 75 4 90 1 4 7 Sliding 10 max 90 1 S8VK G030 30 W 110 1 106 5 7 62 16 32 1 Rail Stopper 75 4...

Page 13: ...8 Rail Stopper 4 7 Sliding 7 5 max S8VK G12024 120 W 1 140 145 6 10 4 6 35 6 35 19 8 Rail Stopper 150 1 4 7 Sliding 7 5max 104 6 60 1 125 1 S8VK G240 240 W 10 4 140 145 6 1 6 35 6 35 30 25 19 8 Rail...

Page 14: ...f there is a possibility that the Unit will be subject to vibration or shock use a steel DIN Rail Otherwise metallic filings may result from aluminum abrasion 4 5 15 25 25 10 10 1 000 500 25 25 15 5 3...

Page 15: ...r 30 and 60 W models S82Y VS10S Side mounting bracket for 120 W models S82Y VK10S Side mounting bracket for 240 W models S82Y VK20S Type Model Dimensions Appearance Front mounting bracket For 15 30 an...

Page 16: ...bracket For 120 W models S82Y VK10S Side mounting bracket For 240 W models S82Y VK20S 35 64 t 2 0 80 60 0 1 55 0 1 13 4 5 dia 0 1 Left side mounting Right side mounting 140 0 1 50 0 1 15 5 0 1 150 12...

Page 17: ...r Do not allow any pieces of metal or conductors or any clippings or cuttings resulting from installation work to enter the Product CAUTION Indicates a potentially hazardous situation which if not avo...

Page 18: ...0 5 to 2 5 mm2 AWG14 to 12 2 5 to 4 mm2 2 5 to 4 mm2 8 to 10 mm S8VK G01512 AWG22 to 12 0 35 to 4 mm2 0 35 to 2 5 mm2 S8VK G01524 AWG24 to 12 0 25 to 4 mm2 0 25 to 2 5 mm2 S8VK G03005 AWG24 to 12 0 2...

Page 19: ...ng horizontally always place the side with the label facing upward DIN Rail Mounting To mount the Block on a DIN Rail hook portion A of the Block onto the rail and press the Block in direction B To di...

Page 20: ...5 to 40 C 2 Up to two of the same model can be connected in parallel 3 Adjust the output voltage difference of each Power Supply to 50 mV or less using the output voltage adjuster V ADJ 4 There is no...

Page 21: ...unt of surge voltage such as a lightening surge occurs while turning ON the power supply In case there is no output voltage please check the following points before contacting us Checking overload pro...

Page 22: ...nents to achieve the original product functions and performance However the influence of the ambient temperature on aluminum electrolytic capacitors is large and the service life is reduced by half fo...

Page 23: ...CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Pr...

Page 24: ...omron com Kyoto JAPAN OMRON ASIA PACIFIC PTE LTD No 438A Alexandra Road 05 05 08 Lobby 2 Alexandra Technopark Singapore 119967 Tel 65 6835 3011 Fax 65 6835 2711 OMRON CHINA CO LTD Room 2211 Bank of Ch...

Reviews: