![Omron R88D-GN Series Datasheet Download Page 3](http://html1.mh-extra.com/html/omron/r88d-gn-series/r88d-gn-series_datasheet_742797003.webp)
G-Series servo drive
3
Servo drive part names
I/
O si
gn
a
l
Sequence input signal
Emergency stop, 3 external latch signals, forward/reverse torque limit, forward/reverse run prohibit, origin prox-
imity, 3 general-purpose inputs
Sequence output signal
It is possible to output three types of signals: positioning completed, speed coincidence, rotation speed detection,
servo ready, current limit, speed limit, brake release and warning signal
I
n
tegrate
d
functio
n
s
Com
m
uni
ca
tio
n
s
RS-232
communications
Interface
Personal computer
Transmission rate
From 2400 to 57600 bps
Functions
Parameter setting, status display, alarm display (monitor, clear, history), servo drive data tracing function, test
run/autotuning operations, real time trace, absolute encoder setting, default values function
MECHATROLINK
communications
Communications protocol MECHATROLINK-II
Transmission rate
10 Mbps
Data length
17 bytes and 32 bytes
Functions
Parameter setting, status display, alarm display (monitor, clear, history), default values function
Automatic load inertia detection
Horizontal and vertical axis mode. One parameter rigidity setting.
Dynamic brake (DB)
Operates when main power OFF, servo alarm, overtravel or servo OFF
Regenerative processing
Built-in regeneration resistor in models from 750 W to 1.5 kW. External regeneration resistor optionally.
Overtravel (OT) prevention function
Dynamic brake, disables torque or emergency stop torque during POT and NOT operation
Emergency stop (STOP)
Emergency stop input
Encoder divider function
Optional division pulses possible
Electronic gearing
0,01<Numerator/Denominator<100
Internal speed setting function
8 internal speeds
Protective functions
Overvoltage, undervoltage, overcurrent, overload, regeneration overload, servo drive overheat
Analog monitor Ouput
The actual servomotor speed, command speed, torque and number of accumulated pulses can be measured u-
sing an oscilloscope or other device.
Panel operator
Display functions
A 2-digit 7-segment LED display shows the servo drive status, alarm codes, parameters, etc.
MECHATROLINK-II communications status LED indicator (COM)
Switches
Rotary switch for setting the MECHATROLINK-II node address
Servo drive type R88D-GN
@
01H-ML2
02H-ML2
04H-ML2
08H-ML2
10H-ML2
15H-ML2
Applicable
servomotor
R88M-G
@
05030
@
/10030
@
20030
@
40030
@
75030
@
G1K020T
@
90010T
@
/ 1K030T
@
/
1K5
@
0T
@
R88M-GP
@
10030
@
20030
@
40030
@
-
-
-
Control I/O connector (CN1)
Encoder connector (CN2)
G
IM
SP
COM
X10
3
2
1
0
ADR
AC SERVO DRIVE
X1
6
7
8
9
0 1
2
3
4
5
Display area
Rotary switches
for ML-II node address
ML-II comms
status LED indicator
RS-232 comms connector (CN3)
ML-II comms connector
(CN6A, CN6B)
Analog monitor check pins
(SP, IM, G)
Main-circuit power terminals
(L1, L2, L3)
Control-circuit power terminals
(L1C, L2C)
External regenerative resistor
connection terminals (B1, B2, B3)
Servomotor connection terminals
(U, V, W)
Protective ground terminals