Important:

• R5-I  Blood 

       pressure 

      measurements 

     are  

    not 

   possible    in   cases  of  severe

arteriosclerosis (hardening of the arteries).

• The  pulse  display  is  not  suitable  for  measuring  the  frequency  of  cardiac

pacemakers.

• Please be sure to wrap the cuff around your wrist before starting. 

 Furthermore,  do  not  inflate  the  cuff  without  wrapping  it  round  your wrist.

• Do not use a portable phone near this unit. This unit may operate erroneous-

ly.

Please  remember:

Self-measurement  is  not  the  same  as  medical  treatment!  You  should

never  change the  dose  of  medicines  prescribed  by  your  doctor .

• If you suffer from disorders of heart rhythm (arrhythmia), you should consult

your doctor before using this blood pressure monitor. In certain cases the

oscillometric measuring method may produce incorrect readings or no read-

ings at all.

• Pregnant women should only measure their own blood pressure in consul-

tation with their doctor, since the readings may be changed by pregnancy.

Inserting  the  batteries
Open the battery compartment on the

right-hand side of the monitor by push-

ing the cover outwards, applying gentle

pressure.

When  inserting  the  batteries,  make

sure  that  the  +/-  poles  agree  with  the

symbols  in  the  battery  compartment.

Use two identical 1.5 V batteries (type

LR03 alkaline).
If you do not intend to use the monitor

for  a  prolonged  period,  you  should

remove the batteries.

If the (

)  symbol  appears,  or  if  the  display  remains  blank  when  you

switch the monitor on, please change both batteries. Only use new, high-

quality alkaline batteries.

In some rare cases there are people where this measuring method does 

not work due to physical structure. In such cases OMRON recomends to

consult a doctor.

R5-I

4

5

3

1

2

SYS

mmHg

DIA

mmHg

PULSE/min

M

DATE/TIME SET

Systolic Blood

Pressure Display

Time Setting Button

START/STOP

Button

Battery Cover

Wrist Cuff

Memory Call Button

Diastolic Blood Pressure

/ Pulse Display

Holding the O/I     button down may shorten batterie life. To avoid pressure 

on the button when transporting or storing, use the case.

I

How  to  measure  your  blood  pressure

Summary of Contents for R5-I

Page 1: ...tions R5 I Tensiomètre entièrement automatique pour prise de mesure au poignet Manual de instrucciones R5 I Aparato completamente automático para medir la presión arterial en la muñeca Manuale di instruzioni R5 I Misuratore della pressione per il polso completamente automatico English Page 1 11 Deutsch Seite 12 22 Nederlands Pagina 23 33 Français Page 34 44 Italiano Pagina 45 55 Español Página 56 ...

Page 2: ...ical data 9 General information about high blood pressure 10 11 Important instructions for obtaining meaningful blood pressure readings Avoid eating and drinking alcohol smoking sport and taking medicines before measuring your blood pressure as these activities influence your blood pressure values Before you start sit comfortably on a chair and relax Measurement must be carried out calmly and with...

Page 3: ...be changed by pregnancy Inserting the batteries Open the battery compartment on the right hand side of the monitor by push ing the cover outwards applying gentle pressure When inserting the batteries make sure that the poles agree with the symbols in the battery compartment Use two identical 1 5 V batteries type LR03 alkaline If you do not intend to use the monitor for a prolonged period you shoul...

Page 4: ...tor the display will flash 1 Set the Year Press the Time Setting button again 2000 year is displayed with flashing Press the Memory Call button and set the number representing the Year 2 Set the Month Press the Time Setting button 1 month representing January in this case is displayed with flashing Press the Memory Call button and set the number representing the Month SYSmmHg DIAmmHg PULSE m in DA...

Page 5: ... when 00 is displayed The current time is displayed and the time setting is completed If you measure blood pressure without setting the date and time blood pressure values will be saved with the incorrect date and time When you use this monitor for the first time or after taking out batteries for a long period of time be sure to adjust the date and time then use the monitor After battery replaceme...

Page 6: ... the cuff is not fitted comfortably and firmly correct measurement is not possible The remaining part of the wrist cuff can be conveniently folded back out of the way If your finger touches the shoulder it is the right level 1 Take a correct posture so that the wrist cuff is at the same level as the heart height of a nipple 2 Be sure to sit on a chair and take a correct posture 4 Wrap the wrist cu...

Page 7: ...ll be stored in the memory Display of pulse rate Alternating display Display of measurement results Measurement of blood pressure is now complete Press the O I button to turn power off Should you forget to turn off the power it will turn itself off automatically after 2 minutes The previous reading will remain in the memory even if the batteries run down or are replaced E E E I If you wish to repe...

Page 8: ...y In order to recall the values measured previ ously push the MEMORY Button M again If there is no measured value in the memory the display shown to the right is indicated when the MEMORY Button M is pushed is possible after measurement or directly when device is switched off SYSmmHg DIAmmHg PULSE min DAT E TI ME SET SYSmmHg DIAmmHg PULSE min DAT E TI ME SET M SYSmmHg DIAmmHg PULSE min DAT E TI ME...

Page 9: ... The cuff pressure does not rise even though the pump motor can be heard The batteries are weak or exhausted Rectification Repeat the measurement keeping perfectly still Do not move your arm or hand and do not talk Attach the cuff so that it fits closely Check that the cuff is firmly fitted to the monitor Contact supplier or Fit two new LR03 alkaline batteries E E E E Faults and their possible cau...

Page 10: ...without prior notice EU representative OMRON Healthcare Europe B V WEGALAAN 57 NL 2132 JD HOOFDDORP 0197 Type B Operating temperature 10 C to 40 C humidity 30 to max 85 relative humidity Storage temperature 20 C to 60 C humidity 10 to max 95 RH The accuracy of this blood pressure monitor has been carefully tested and is designed for a long service life It is generally recommended to have the monit...

Page 11: ...eries when the blood flows through them The higher blood pressure value systolic pressure or top value signifies the blood pressure produced by contraction of the heart muscle and subsequent pumping of blood into the arterial system There is no universally accepted definition of hypotension However those having the systolic pressure below 100 mmHg are assumed as hypotension The lower blood pressur...

Page 12: ...ptoms The following are all possible causes of abnormally high blood pressure Overweight High cholesterol level Smoking Excessive alcohol consumption Stress and emotional upsat Excessive consumption of salt Lack of physical exercise Genetic hereditary predisposition Underlying illnesses such as kidney disorders or endocrine disturbance If your blood pressure reaches upper values of 140 160 mmHg an...

Reviews: