CmdDat[0] :=BYTE#16#05; // Set command array.
CmdDat[1] :=BYTE#16#01;
END_IF;
IF (DoFinsTrigger=TRUE) THEN
SendCmdInstance( Execute :=SendCmdExecute,
DstNetAdr:=InDNetAdr,
CommPort :=_NONE,
CmdDat := CmdDat [0],
CmdSize :=UINT#2,
RespDat := RespDat [0],
Option :=InOption);
CASE State OF
1: // Execute SendCmd.
SendCmdExecute := TRUE;
IF (SendCmdInstance.Done=TRUE) THEN
State := 2;
ELSIF (SendCmdInstance.Error=TRUE) THEN
State := 99;
END_IF;
2: // Normal processing
Trigger := FALSE;
DoFinsTrigger:=FALSE;
99: // Abnormal processing
Trigger := FALSE;
DoFinsTrigger:=FALSE;
END_CASE;
END_IF;
3 Client Function
3 - 18
NX-series CPU Unit FINS Function User's Manual (W596)
Summary of Contents for NX102-10 Series
Page 24: ...Sections in this Manual 22 NX series CPU Unit FINS Function User s Manual W596...
Page 36: ...2 Server Function 2 6 NX series CPU Unit FINS Function User s Manual W596...
Page 40: ...2 Server Function 2 10 NX series CPU Unit FINS Function User s Manual W596...
Page 65: ...I Index I 1 NX series CPU Unit FINS Function User s Manual W596 I...
Page 67: ......