Programmable Terminals

Cat. No. V098-E1-04

OPERATION MANUAL

Summary of Contents for NS - REV 04

Page 1: ...Programmable Terminals Cat No V098 E1 04 OPERATION MANUAL ...

Page 2: ...s used by NS series Programmable Terminals for Host Link communications First familiarize yourself with the contents of the manuals related to NS series Programmable Terminals the NS series Setup Manual NS series Programming Manual and the CX Designer online help and then use this manual for Host Link communications ...

Page 3: ...ettings in the host PLC NS V1 V2 PT serial ports A and B can both be connected to a host by means of the Host Link protocol Reference When an NS V1 V2 PT and a PLC are connected by Host Link it is not possible to change to RUN Mode If the PLC is set for RUN Mode it is automatically switched to Monitor Mode For example if a compatible Programming Console is connected to the PLC and the PLC operatin...

Page 4: ...ith the host by Host Link communications Model NS12 TS0 B V1 V2 NS10 TV0 B V1 V2 NS8 TV0 B V1 V2 NS8 TV1 B V1 NS5 SQ B V1 V2 NS5 TQ B V2 NS5 MQ B V2 Reference NS series PTs without the V1 or V2 suffix do not support Host Link communications One of the above NS V1 V2 models must be used NS V1 V2 System Program To connect to the host by means of Host Link communications system program version 6 or l...

Page 5: ...wing table shows the communications methods that can be used in combination when serial ports A and B are used at the same time Serial port B Host Link 1 1 NT Link 1 N NT Link Memory link Bar code reader Temperature controller CX Designer connection Host Link YES YES YES YES YES YES YES 1 1 NT link YES YES YES YES YES YES YES 1 N NT Link YES YES YES YES YES YES YES Memory link YES YES YES No YES Y...

Page 6: ...or 19 200 bps See note 1 Note 1 The baud rate settings must be the same for both the NS V1 V2 PT and the host 2 Use the 1 N protocol setting 1 2 2 Applicable PLCs The OMRON PLCs listed below can be connected as hosts using Host Link communications The connection can be made either directly to the built in serial port on the CPU Unit or to a Host Link Unit mounted to the PLC C Series C200HS C200HX ...

Page 7: ...CS1H CPU63 64 65 66 67 EV1 CS1G CPU42 43 44 45 EV1 CS1H CPU63 64 65 66 67 EV1 CS Series CS1G CPU42H 43H 44H 45H CS1H CPU63H 64H 65H 66H 67H CS1G CPU42H 43H 44H 45H CS1H CPU63H 64H 65H 66H 67H CS1W SCU21 V1 CS1W SCB21 V1 CS1W SCB41 V1 CJ1G CPU44 CPU45 CJ1G CPU44 CPU45 CJ1G CPU42H 43H 44H 45H CJ1H CPU65H 66H 67H CJ1H CPU65H 66H 67H R CJ2H CPU64 65 66 67 68 EIP CJ1G CPU42H 43H 44H 45H CJ1H CPU65H 66H...

Page 8: ...apter to connect 2 The CQM1H CPU11 does not have a built in RS 232C port so connect to the peripheral port to the PT with a CS1W CN118 Connecting Cable 3 CPU Units of CVM1 CV series PLCs without the suffix EV cannot be connected Settings at the Host When using the host link method the settings shown below must be made at the host depending on the unit some of these settings may not be necessary or...

Page 9: ...W1 SW2 Set these switches to 0 Command level parity and transfer code SW4 Set this switch to 2 Communications speed SW3 Set this switch to 5 to select 9600 bps Set this switch to 6 to select 19200 bps Setting the Rear Switches 1 to 1 1 to N selection DIP switch Set 3 to ON CTS selection selector switch Set this always to 0 V ON CTS selector switch External 0 V ON C1000H C2000H Rack mounted type C5...

Page 10: ...always to 0 V ON I O port Synchronization Terminator 0 V C1000H F C2000H Rack mounted type C500 LK203 Setting the Rear Switches I O port selection selector switch Set this to RS 232C Unit parity and transfer code DIP SW1 1 to SW1 7 Set SW1 1 to SW1 7 to OFF 0 Synchronization selector switch Set this to Internal Communications speed DIP SW2 1 to SW2 4 Set these switches to 0010 to select 19 200 bps...

Page 11: ...thod However since the connectors at these ports are of different types a cable that matches the connector must be prepared Communications port 1 Communications port 1 is a 25 pin connector for RS 232C use only Communications port 2 Communications port 2 is a 9 pin connector which allows selection of the RS 232C or RS 422A method When this port is used with the RS 232C method the I O port selector...

Page 12: ...uted Communication method Full duplex Stop bits 2 stop bits Data length 7 bits Connecting to a CS series Serial Communications Unit CS series Rack mounted type CS1W SCU21 V1 Setting the Front Switches Set the unit number of the Serial Communications Unit by using the rotary switch located on the front panel Set each switch with a flat blade screwdriver so that the values or symbols in the setting ...

Page 13: ...dure below use a flat head screwdriver to set the number and sign in the setting display window Port 2 on the CJ1W SCU41 V1 is an RS 232C port Unit Number Setting Set a number from 0 to F that does not overlap another unit Port 1 RS 232C Port 2 RS 232C CJ1W SCU21 V1 Unit Number Setting Set a number from 0 to F that does not overlap another unit Port 2 RS 232C CJ1W SCU41 V1 Setting CPU Unit Allocat...

Page 14: ... EV2 PLC Setup When connecting to a CVM1 CV series CPU Unit set the following communications conditions for the PLC Setup Item Setting at Host Communications speed Set the same baud rate as set at the NS series PT See note Stop bit 2 stop bits Parity Even Data length ASCII 7 bits Unit 00 Note Set the Host Link communications speed baud rate to 9600 bps or 19200 bps with the Communications Setting ...

Page 15: ...s built in RS 232C port Connect to one of the RS 232C ports port A or port B on a Serial Communications Board CQM1H Connect to the CPU Unit s built in RS 232C port Connect to the peripheral port through a CS1W CN118 Connecting Cable Connect to the RS 232C port port 1 on a Serial Communications Board CPM1 Connect to the peripheral port through a CPM1 CIF01 RS 232C Adapter CPM2A SRM1 Connect to the ...

Page 16: ...03 Data length 7 bits 2 stop bits even parity communications speed 9600 bps DM6651 0304 Data length 7 bits 2 stop bits even parity communications speed 19200 bps DM6653 0000 Unit 00 C200HS C200HX HG HE Z E CPM2A CPM2C CQM1 CQM1H other than the CPU11 or SRM1 Built in RS 232C port connection Word Writing Value Settings DM6645 0001 Host link mode no CTS control communications conditions set by the co...

Page 17: ...e CPM2C s communications port handles both RS 232C and peripheral port connections which are divided internally Therefore when using the CPM2C it is necessary to select RS 232C or peripheral port connections according to the kind of cable and port on the cable used as shown in the following table Refer to the CPM2C Operation Manual for more details Port connecting to PT PLC Setup RS 232C port D Su...

Page 18: ...itches on the front panel must be set as shown below in order to make the PLC Setup settings effective The settings for SW1 and SW2 depend upon the usage of the peripheral port and RS 232C port Connecting PT to peripheral port Connecting PT to built in RS 232C port A device that requires non standard communications settings is connected to the peripheral port Connecting PT to built in RS 232C port...

Page 19: ...Communications Setting menu item in the CX Designer and the System Menu for the NS series PT For details refer to 1 4 Settings for Host Link When the communications speed is set to 19200 bps the PLC Setup of the CPU Unit need to be changed Either set the PLC Setup directly from a Programming Device Programming Console or transmit the PLC Setup made at a Programming Device CX Programmer to the CPU ...

Page 20: ...ttings are written they become effective by turning the power ON restarting the unit restarting the communications port or execution of the STUP command In the following the words allocated in the DM area and the settings are shown Allocation DM area word Port 1 Port 2 Writing Value Settings D32000 D32010 8000 Host link mode 2 stop bits even parity data length 7 bits 0000 Communications speed 9600...

Page 21: ...66H 67H R CJ2H CPU64 65 66 67 68 EIP CJ1M CPU11 12 13 21 22 23 CJ1W SCU41 V1 CP1H XA40DR A XA40DT D XA 40DT1 D X40DR A X40DT D X4 0DT1 D Y20DT D CJ Series CP1L L14DR A L14DR D L14DT D L14DT1 D L20DR A L20DR D L20DT D L20DT1 D M30DR A M 30DR D M30DT D M30DT1 D M 40DR A M40DR D M40DT D M4 0DT1 D CP1W CIF11 C1000H CPU01 EV1 C2000H CPU01 EV1 C120 LK202 EV1 C200HS CPU01 03 21 23 31 33 E C200HE CPU11 32...

Page 22: ...s is for connecting to an OMRON Temperature Controller Do not connect it to an NS series PT or PLCs using RS 485 Settings at the Host When using the RS 422A type host link method the settings shown below must be made at the host depending on the unit some of these settings may not be necessary or settings not shown here may be necessary Item Setting at Host I O port RS 422A Communications speed Se...

Page 23: ...the setting value window agree with the following Unit SW1 SW2 Set these switches to 0 Command level parity and transfer code SW4 Set this switch to 2 Communications speed SW3 Set this switch to 5 to select 9600 bps Set this switch to 6 to select 19200 bps Setting the Rear Switches Terminator setting selector switch Set this switch to ON 1 to 1 1 to N protocol selection selector switch Set this sw...

Page 24: ... switch Set this to Internal Communications speed DIP SW2 1 to SW2 4 Set these switches to 0010 to select 19200 bps Set these switches to 1010 to select 9600 bps 0 OFF 1 ON 1 to 1 1 to N selection DIP SW2 6 Set SW2 6 to OFF 0 1 to N Command level DIP SW2 7 SW2 8 Set these switches to ON 1 Levels 1 2 and 3 are enabled CTS selection selector switch Set this always to 0 V ON Terminator setting select...

Page 25: ...his always to 0 V ON Terminator setting selector switch Set this switch to ON I O port Synchronization Terminator 5V supply 0 V C200H C1000H C2000H CPU mounted Type C120 LK202 EV1 Setting the Rear Switches Unit parity and transfer code DIP SW1 1 to SW1 5 Set SW1 1 to SW1 5 to OFF 0 Parity is fixed at Even Parity Transfer code is fixed at ASCII 7 data bits and 2 stop bits Communications speed DIP S...

Page 26: ...or the CPU Bus Unit settings Item Setting at Host Communications speed Set the same baud rate as set at the NS series PT See note 1 Transfer code ASCII 7 data bits 2 stop bits Parity Even 1 to 1 1 to N 1 to N See note 2 Command level Level 1 2 3 Note 1 Set the Host Link communications speed baud rate to 9600 bps or 19200 bps with the Communications Setting menu item in the CX Designer and the Syst...

Page 27: ...nits CV500 CPU01 EV1 CV1000 CPU01 EV1 CV2000 CPU01 EV1 CVM1 CPU01 EV2 CVM1 CPU11 EV2 CVM1 CPU21 EV2 PLC Setup When connecting to a CVM1 CV series CPU Unit set the following communications conditions for the PLC Setup Item Setting at Host Communications speed Set the same baud rate as set at the NS series PT See note Stop bit 2 stop bits Parity Even Data length ASCII 7 bits Unit 00 Note Set the Hos...

Page 28: ...IP SW6 Set this switch to ON Set terminator ON I O port selector switch C series C200HX HG HE Z E CPM1 CPM2A CPM2C CQM1H CPU Unit or SRM1 The connection method depends upon the model of PLC being used as shown in the following table PLC model Connection method C200HX HG HE Z E Connect to the RS 422A port port A on a Communications Board CQM1H Connect to the RS 422A port port 2 on a Serial Communic...

Page 29: ...tions relating to the PLC Setup area refer to the manual for the PLC which is used The PLC Setup area word numbers and settings to be made depending on the unit to which the connection is made are shown below When using port A of the Communications Board of C200HX HG HE Z E Word Writing Value Settings DM6555 0001 Host link mode no CTS control communications conditions set by the contents of DM are...

Page 30: ...cording to the kind of cable and port on the cable used as shown in the following table Refer to the CPM2C Operation Manual for more details Peripheral port RS 232C port D Sub 9 pin female Peripheral port Setting Switches on a C200HX HG HE Z E Communications Board Set the switches on a C200HX HG HE Z E Communications Board as follows Switch 1 Set to 4 4 wire type for RS 422A Switch 2 Set to ON for...

Page 31: ...rogrammer directly into the allocation DM area system setting area of the CPU Unit After the settings are written they become effective by turning the power ON restarting the unit restarting the communications port or executing the STUP command In the following the words allocated in the DM area and the settings are shown Allocation DM area word Port 2 Writing Value Settings D32010 8000 Host link ...

Page 32: ...ght side Port 1 RS 422A 485 Setting Parameters Allocated in the DM Area in the CPU Unit Settings can be directly written to the words allocated to the Serial Communications Unit in the DM Area System Setup Area by using a Programming Device such as a Programming Console or the CX Programmer Any changes to the settings can be enabled by cycling the power supply restarting the Unit restarting the co...

Page 33: ...alog Box Select Serial Port A or Serial Port B Then set the serial port to PLC and the protocol to Host Link 1 4 2 Transferring Screen Data Use the transfer program to transfer the screen data to the NS V1 V2 PT For details on transferring screen data refer to Transferring Data to the PT in the CX Designer online help 1 4 3 Setting the Communications Method for Serial Port A or B This procedure is...

Page 34: ...Buttons to display the screen for page 2 3 2 Press the drop down menu button and set Host Link as the communications method for serial port A or B 3 Press the Detail Button to display the Host Link settings and select Comm Speed 4 Press the Write Button and press the Yes Button on the following dialog boxes to restart the NS V1 V2 NS12 NS10 NS8 V1 V2 PT The screen is somewhat different for the NS1...

Page 35: ...ct in the same way as for a 1 1 NT Link and use the same cables that are used for a 1 1 NT Link connection If cables must be prepared refer to the relevant manuals for the PLC or Host Link Unit and to the NS Series Setup Manual Cat No V083 ...

Page 36: ...to 06655 07000 to 09999 00000 to 06143 C500 00000 to 00063 00000 to 00031 00000 to 00031 00000 to 00127 00000 to 00511 C1000H 00000 to 04095 C2000H CQM1 00000 to 06655 CQM1H 00000 to 00255 00000 to 00099 00000 to 00027 00000 to 00063 00000 to 00511 00000 to 06655 00000 to 06143 CPM1 CPM1A 00000 to 00019 00200 to 00255 00000 to 00015 00000 to 00127 00000 to 01023 06144 to 06655 Ladder type PLCs CPM...

Page 37: ... 1 The HR Area is included in the CIO Area To use the HR Area specify the CIO Area 2 Do not use this area for creating screens It cannot be used with Host Link communications OMRON CS CJ series PLCs PLC model Common I O Area CIO Holding Relay HR Auxiliary Relay AR Link Relay LR Timer Counter Area TIM CNT Data Memory Area DM EM Area Current bank See note 1 00000 to 06143 00000 to 00511 00000 to 009...

Page 38: ...rlier first use CX Designer to convert the project to version 6 0 or later before transferring it to the NS V1 V2 PT Applicable Serial Ports Either NS V1 V2 serial port A or B can be used to connect to the host by means of Host Link communications Applicable NS Models Only NS series PT models with a V1 V2 suffix can be used to connect to the host by means of Host Link communications NS series PT m...

Page 39: ...004 Original production 02 July 2006 Revisions made for the release of the CX Designer 03 July 2007 Pages 6 and 20 CJ series CPU Unit model numbers added 04 June 2008 Cover Added models to list of NS series PT Page 3 Added 3 models to end of model table in section 1 2 1 Page 5 Added CJ2H to list of CS CJ series PLCs Pages 6 and 19 Added models to CJ series PLCs in table Page 26 Added CJ2H to PLC m...