73
Receiver Error Codes
Section 17-5
Cascaded Sys-
tem Fault
80
Configuration Error
Please contact your local Omron distributor
or the European Repair Center
81
Second segment or mute module error
Check all cable connections. Please contact
your local Omron distributor or the Euro-
pean Repair Center
82
Third segment or mute module error
Check all cable connections. Please contact
your local Omron distributor or the Euro-
pean Repair Center
83
Fourth segment or mute module error
Check all cable connections. Please contact
your local Omron distributor or the Euro-
pean Repair Center
84
Mute module error
Check all cable connections to mute mod-
ule. Please contact your local Omron dis-
tributor or the European Repair Center
85
Configuration error
Please contact your local Omron distributor
or the European Repair Center
86
Second segment or mute module firmware
not compatible with first segment
Replace with compatible component or
return system to Omron distributor or Euro-
pean Repair Center
87
Third segment or mute module firmware not
compatible with first segment
Replace with compatible component or
return system to Omron distributor or Euro-
pean Repair Center
88
Fourth segment or mute module firmware
not compatible with first segment
Replace with compatible component or
return system to Omron distributor or Euro-
pean Repair Center
89
Mute module firmware not compatible with
first segment
Replace with compatible component or
return system to Omron distributor or Euro-
pean Repair Center
90
Incorrect segment type in position two,
three or four
Confirm that all segments are of the same
type; either all transmitters or receivers
91
Segment 2 type does not match segment 1
type
Confirm that segment 2 is the same type
(transmitter or receiver) as segment 1
92
Segment 3 type does not match segment 1
type
Confirm that segment 3 is the same type
(transmitter or receiver) as segment 1
93
Segment 4 type does not match segment 1
type
Confirm that segment 4 is the same type
(transmitter or receiver) as segment 1
95
Error in flex segment or muting module dur-
ing operation
Check all flex connections, segments and
muting modules
96
Error in segment 2 during operation
Check connections to segment 2. Replace
segment 2 with known good segment 2.
Please contact your local Omron distributor
or the European Repair Center
97
Error in segment 3 during operation
Check connections to segment 3. Replace
segment 3 with known good segment 3.
Please contact your local Omron distributor
or the European Repair Center
98
Error in segment 4 during operation
Check connections to segment 4. Replace
segment 4 with known good segment 4.
Please contact your local Omron distributor
or the European Repair Center
100
Number of segments in system has been
reduced (changed)
Segment count is less than original configu-
ration. Add required segment(s) or program
system for current configuration
101
Too many flex nodes or muting modules in
the flex bus
Make sure of total of 4 segments with only
one muting module.
Code Group
Error Code
Description of Error Code
Corrective Action Needed
Summary of Contents for MS2800E
Page 3: ...iv ...
Page 5: ...vi ...
Page 19: ...2 Section ...
Page 25: ...8 MS2800FS Cascaded Series Section 4 3 ...
Page 33: ...16 Optical Synchronization Section 5 4 ...
Page 39: ...22 Selecting Scan Codes Section 7 7 ...
Page 41: ...24 Auxiliary Output Section 8 2 ...
Page 51: ...34 General Mounting Considerations Section 10 3 ...
Page 57: ...40 Using the test object Section 13 3 ...
Page 59: ...42 Section ...
Page 85: ...68 Accessories Section 15 9 ...
Page 87: ...70 Section ...
Page 91: ...74 Receiver Error Codes Section 17 5 ...
Page 95: ...78 ...