![background image](http://html1.mh-extra.com/html/omron/ms2800e/ms2800e_operation-manual_744011048.webp)
31
General Mounting Considerations
Section 10-3
10-3 General Mounting Considerations
10-3-1 Additional Guarding
Areas of access to the point of hazardous operation not guarded by the
MS2800 system must be protected by suitable means such as a fixed barrier
guard, an interlocked guard or a safety mat system.
10-3-2 Added Mounting Rigidity
It is recommended that when installing a
MS2800 larger than 1000 mm in length,
you use an additional mounting bracket.
This is to be installed using the T-slot on
the backside of the transmitter and
receiver.
Supplemental
Guarding
Supplemental
Guarding
Hazard
Zone
Ds
LIGHT CURTAIN
Supplemental
Guarding
Example
Mechanical
Barrier
Supplemental
Guarding
Supplemental
Guarding
MS2800 point of
operation guarding
MS2800FS 3-sided guarding
MS2800FS 2-Axis guarding
ALTERNATE
T-SLOT
MOUNTING
ALTERNATE
T-SLOT
MOUNTING