background image

A-34

General-purpose Relay 

LY

Contact Ratings

*Note:

P level: 

λ

60

 = 0.1 x 10

-6

/operation, reference value

Characteristics

Note: 1.

The values given above are initial values.

2.

The upper limit of 40

°

C for some Relays is because of the relationship between diode junction temperature and the element used.

Relay

Single contact

Bifurcated contacts

1-pole

2-, 3- or 4-pole

2-pole

Load

Resistive load 

(cos

φ

 = 1)

Inductive load 

(cos

φ

=0.4, 

L/R=7 ms)

Resistive load 

(cos

φ

 = 1)

Inductive load 

(cos

φ

=0.4, 

L/R=7 ms)

Resistive load 

(cos

φ

 = 1)

Inductive load 

(cos

φ

=0.4, 

L/R=7 ms)

Rated load

110 VAC 15 A
24 VDC 15 A

110 VAC 10 A
24 VDC 7 A

110 VAC 10 A
24 VDC 10 A

110 VAC 7.5 A
24 VDC 5 A

110 VAC 5A
24 VDC 5 A

110 VAC 4 A
24 VDC 4A

Rated carry 
current

15 A

10 A

7 A

Max. 
switching 
voltage

250 VAC
125 VDC

250 VAC
125 VDC

250 VAC
125 VDC

Max. 
switching 
current

15 A

10 A

7 A

Max. 
switching 
power

1,700 VA
360 W

1,100 VA
170 W

1,100 VA
240 W

825 VA
120 W

550 VA
120 W

440 VA
100 W

Failure rate 
(reference 
value)*

100 mA, 5 VDC 

100 mA, 5 VDC 

10 mA, 5 VDC 

Item

All except Relays with bifurcated contacts

Relays with bifurcated contacts

Contact resistance

50 m

 max.

Operate time

25 ms max.

Release time

25 ms max. 

Max. operating frequency

Mechanical:

18,000 operations/hr

Electrical:

1,800 operations/hr (under rated load)

Insulation resistance

100 M

 min. (at 500 VDC)

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity

Vibration resistance

Destruction:

10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)

Malfunction:

10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)

Shock resistance

Destruction:

1,000 m/s

2

Malfunction:

200 m/s

2

Endurance

Mechanical:

AC:

50,000,000 operations min. (at 18,000 operations/hr)

DC:  1,00,000,000 operations min. (at 18,000 operations/hr)

Electrical:

Single-, three-, and four-pole: 200,000 operations min. (at 1,800 operations/hr 
under rated load)
Double-pole: 500,000 operations min. (at 1,800 operations/hr under rated load)

Ambient temperature*

Operating: 
Single- and double-pole standard, bifurcated-contact Relays: –25

°

C to 55

°

C (with no icing) 

(–25

°

C to 70

°

C if carry current is 4 A or less)

All other Relays: –25

°

C to 40

°

C (with no icing) (–25

°

C to 55

°

C if carry current is 4 A or less)

Ambient humidity

Operating: 

5% to 85%

Weight

Single- and double-pole: approx. 40 g, three-pole: approx. 50 g, four-pole: approx. 70 g

Summary of Contents for LY -

Page 1: ...oil ratings table 2 Relays with 187 quick connect terminals are also available with SPDT and DPDT contact Ask your OMRON representative for details 3 SEV models are standard Relays excluding DPDT bifu...

Page 2: ...el Clip model Standard bifurcated contacts oper ation indicator built in diode 1 2 PTF08A E PTF08A PYC A1 PT08 QN PT08 0 PYC P 3 PTF11A PT11 QN PT11 0 4 PTF14A E PTF14A PT14 QN PT14 0 CR circuit 2 PTF...

Page 3: ...z 12 V 159 mA 134 mA 24 0 12 H 0 21 H 24 V 80 mA 67 mA 100 0 44 H 0 79 H 50 V 38 mA 33 mA 410 2 24 H 3 87 H 100 110 V 14 1 16 mA 12 4 13 7 mA 2 300 10 5 H 18 5 H 200 220 V 9 0 10 0 mA 7 7 8 5 mA 8 650...

Page 4: ...resistance 50 m max Operate time 25 ms max Release time 25 ms max Max operating frequency Mechanical 18 000 operations hr Electrical 1 800 operations hr under rated load Insulation resistance 100 M m...

Page 5: ...A inrush current 3 A current flow ON for 5 s OFF for 55 s 80 000 operations Capacitor 2 000 F 24 VDC with 50 A inrush current 1 A cur rent flow ON for 1 s OFF for 15 s 10 000 operations 24 VDC with 2...

Page 6: ...use 1 2 HP 120 VAC TV 5 120 VAC 6 x 103 25 x 103 2 15 A 30 VDC Resistive 15 A 120 VAC Resistive 1 2 HP 120 VAC TV 3 120 VAC 6 x 103 3 and 4 10 A 30 VDC Resistive 10 A 240 VAC General use No of poles...

Page 7: ...4 6 8 10 12 14 16 18 20 1 0000 1 000 100 500 5 000 Maximum Switching Power Switching voltage V Endurance Switching current A AC resistive load DC resistive load 24 VDC resistive load 110 VAC resistive...

Page 8: ...0 Maximum Switching Power Switching voltage V Switching current A Endurance Switching current A AC resistive load DC resistive load Life 500 000 operations 24 VDC resistive load 110 VAC resistive load...

Page 9: ...D LY2 Z N LY2 Z N D2 LY2 LY2Z LY2 D LY2Z D LY2N LY2ZN LY2N D2 LY2ZN D2 Eight 3 dia holes 36 max 28 max DC Model AC Model 21 5 max Terminal Arrangement Internal Connections Bottom View 0 5 5 3 6 4 LY3...

Page 10: ...holes 21 5 max Terminal Arrangement Internal Connections Bottom View 0 5 2 1 5 75 4 1 5 5 14 2 10 14 2 10 10 10 10 10 10 3 4 3 4 5 3 5 3 4 6 13 15 7 15 LY1 0 LY3 0 LY2 0 LY4 0 4 5 see note 2 36 max 2...

Page 11: ...es should apply to the LY2F model Two 3 5 dia holes or Two M3 holes 44 max 29 max Eight 2 dia holes see note LY3F 0 5 5 3 6 4 3 5 38 38 0 1 2 36 max 32 max 44 max Two 3 5 dia holes or two M3 holes 28...

Page 12: ...PT08QN PT11QN PT08 0 PT11 0 PTP 1 3 PTP 1 PYP 18 PTP 10 PTP 12 PYP 1 t 1 6 t 1 6 t 1 6 t 1 6 t 1 6 t 1 6 R5 7 7 42 0 1 49 52 0 1 59 49 42 0 1 7 7 42 0 1 49 R5 7 7 42 0 1 49 9 x 49 4 444 6 0 6 9 x 49 4...

Page 13: ...revent them from coming loose due to vibration or shock Precautions Refer to page A 72 for general precautions Connections Do not reverse polarity when connecting DC operated Relays with built in diod...

Page 14: ...rest of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into oun...