background image

Call from Guardroom - How to communicate

1. If the guard calls to the house, tone sound rings and both communication and guard/lobby LED flicker 

at the front side of videophone. 

2. When user presses communication             or guard/lobby button               , communication begins. 

3. When user presses communication             or guard/lobby button                again, communication is   

ended.

Call to guardroom - How to communicate

1. When user presses guard/lobby button               , call signal rings and the button's LED is turned on 

to call guardroom phone. 

2. If handset is picked up in guardroom phone, communication begins (for up to 3 minutes). 

3. If hanging up the handset in guardroom or pressing communication            or guard/lobby button              

on videophone, and communication will be automatically ended. 

Call from lobby phone - How to communicate

1. When a call from lobby phone, both communication            and guard/lobby buttons                 flicker 

(tone sound rings for 30 seconds). 

2. Press communication             or guard/lobby buttons               , and communication will be

available (communication lasts for 3 minutes). 

3. Press door open button            on videophone while communicating with lobby phone to operate 

common gate opener.

4. Press either communication            or guard/lobby button              to end communication.

Monitoring of Lobby (Common Gate) Situations

1. If pressing the guard/ lobby button               around 3 sec. on the monitor for about 3sec, the image 

from lobby phone (common gate camera) is displayed on the monitor screen.

But in case the lobby phone (common gate camera) or guardroom phone is busy, the image from

lobby phone (common gate camera) is not displayed.

2. After 8 sec. of lobby (common gate) monitoring, the monitor screen is automatically turned off.

3. In house, the users can see the image and hear the voice from the lobby phone (common gate camera)

for 8 sec.

4. This lobby (common gate) monitoring function is only available with 10 key type of KLP-100,

KLP-P100 & KLP-C100 lobby phone (common gate camera).

Communication is available only when options are installed. If options are not installed, 
only tone sounds rings.  

Call from In-house Line (When options are installed)

1. When internal call signal, in-house line LED at the front side of videophone flickers. 
2. Press either communication           or in-house line button          to start communication 

(LED keeps On-mode). 

3. Communication is available for up to 3 minutes. When 3 minutes pass, communication is automatically     

ended. 

4. Press either communication             or in-house line          to end communication. 

Internal Call using In-house Line (When options are installed)

1. When user presses in-house line button          , the button's LED flicker and a call signal is sent to  

extended unit.

2. Press communication             or in-house line button          on extended unit to begin 

communication (communication maintains for 3 minutes). 

3. Press communication             or in-house line button         to end communication. 

Users can control chime volume by adjusting 3-level volume switch on videophone.

In all functions, call maintenance time is set for 30 seconds. After 30 seconds, call signal and images 
return to stand-by mode. 

All communications maintains for 3 minutes. After 3 minutes, communication automatically 
returns to stand-by mode.

16

17

Summary of Contents for KIV-212

Page 1: ...ality improvement PRODUCT MODEL DATE PURCHASED WARRANTY PERIOD AGENCY ADDRESS KOCOM Warranties the original purchaser of this product as follows 1 This product is produced under strict quality control and inspection procedures 2 If this product breaks down during proper use as a result of product defect KOCOM will repair it within one year from date of purchase free of charge 3 The following cases...

Page 2: ...2 3 ...

Page 3: ...4 5 ...

Page 4: ...between indoors and outdoors and also eliminates moisture and condensation on door camera window Stop up P V C pipe using adiabatic substances to prevent air circulation MIC Sending the voice to lobby phone guard phone camera and other equipment connecting to in house line Power LED Communication Button When receiving the call signal from interlocked outside equipment user can communicate with it ...

Page 5: ...tallation Bottom base of One hall Box Basic Installation method of Monitor When system is attached to 1 rectangular switch box Standard Height of Monitor Standard height of monitor is ranged 1 450 1 500 from bottom to the center of monitor screen For installation avoid the places where there is any excessive humidity magnetic force dangerous chemicals direct ray of sun and any places near a heater...

Page 6: ...is used 300m Monitor 0 C 50 C Power Source Voltage of Operating Power Lobby Guardroom In house Call Signal Monitoring of Front Door Camera Lobby Phone s Lobby Monitoring Function Call Method Communication Method Image Maintenance Time Number of Wiring Dimensions Communication Distance Guaranteed Operation Temperature KC C60 KC MC35 Front Door Camera KIV 212 Monitor KIV D212 Monitor Component Monit...

Page 7: ...ration or poor communication quality please carefully conduct wiring work When connecting a wiring chord to a terminal loosen screw insert the end of the chord into the bottom part of screw and tighten the screw When fixing wiring chord use stapler not to cause damage to the chord When using existing wiring please be cautious not to cause disconnection and short circuit Wiring for multi houses apa...

Page 8: ...ommunication button By doing so monitor screen is turned on and user can keep communicating with the visitor While communicating with the visitor if user presses the door open button house front door will be opened Monitoring of Front Door Situations 1 Monitoring for Camera 1 If pressing the front door button once on the monitor the image from camera 1 port is displayed on the monitor screen 2 Mon...

Page 9: ...guardroom phone is busy the image from lobby phone common gate camera is not displayed 2 After 8 sec of lobby common gate monitoring the monitor screen is automatically turned off 3 In house the users can see the image and hear the voice from the lobby phone common gate camera for 8 sec 4 This lobby common gate monitoring function is only available with 10 key type of KLP 100 KLP P100 KLP C100 lob...

Page 10: ... Communication with guardroom maintains for 3 minutes When communication is ended device returns to standby mode Stand by House Number Call state Communication state Stand by Stand by Guard Master Number Call state Communication state Stand by Password Change Password change function is only available during the call with house Pressing 0 0 during the call with house is displayed Input new passwor...

Page 11: ...Specification Within DC 12V 300mA Functional specifications may be changed according to the specifications of installed products The numbers are the setting number when the switch is put to ON 1 If DIP SWITCH from 1 to 12 is put to ON the numbers of DIP SWITCH will be summed up ex1 If the switches 1 and 2 are put to ON the setting number becomes 1 2 3 ex2 If the switches 1 and 3 are put to ON the ...

Page 12: ...the result is 8 200 208 the house No 208 In this case DIP SWITCH 1 3 10 is put to ON the result is 1 4 800 805 the house No 805 In this case DIP SWITCH 2 7 11 12 is put to ON the result is 2 100 1000 2000 3102 the house No 3102 ex8 ex9 ex10 In this case DIP SWITCH 1 10 11 12 is put to ON the result is 1 800 1000 2000 3801 the house No 3801 In this case DIP SWITCH 2 6 7 11 12 is put to ON the resul...

Page 13: ... switches excessive impact on DIP switches may cause abnormal or erroneous operation of device 11 9 7 5 3 1 A 12 10 8 6 4 2 B House Setting No The numbers are the setting number when the switch is put to ON 1 If DIP SWITCH from 1 to 12 is put to ON the numbers of DIP SWITCH will be summed up ex1 If the switches 1 and 2 are put to ON the setting number becomes 1 2 3 ex2 If the switches 1 and 3 are ...

Page 14: ...999 ex4 To set the house No 1203 In this case DIP SWITCH 1 4 5 8 9 12 is put to ON the result is 1 8 10 80 100 800 999 the house No 999 In this case DIP SWITCH 1 2 11 12 is put to ON the result is 1 2 400 800 1203 the house No 1203 ...

Reviews: