background image

KIV-212, KIV-D212 User

s Manual for Operation and Installation 

Communication and monitoring by front door camera. 

Interactive call and communication between house and guardroom. 

Inner line call and communication within the house. 

Communication with lobby phone and door open function.

Monitoring of lobby.

For both single house and multi house (Apartments). 

KIV-212 : AC type

KIV-D212 : DC type

COLOR HANDS-FREE 

VIDEO PHONE

Thank you very much 
for purchasing KOCOM 
video doorphone. 
please read this manual 
thoroughly to ensure 
correct usage, before 
operating. 

KIV-212 / KIV-D212    08. 08

This manual is based on the date as shown in the right and specifications 
are subject to change without notice for quality improvement.

PRODUCT

MODEL 

DATE PURCHASED

WARRANTY PERIOD

AGENCY ADDRESS

KOCOM Warranties the original purchaser of this product as follows.

1) This product is produced under strict quality control and inspection procedures.

2) If this product breaks down during proper use as a result of product defect, KOCOM  

will repair it within one year from date  of purchase free of charge.

3) The following cases will be subject to charge, even during warranty period:

a. Breakdown during transport, or through careless treatment,  by consumer.

b. Breakdown cause by unauthorized repair, or system  modification.

c. Breakdown caused by natural disaster or power disorder. 

Warranty 

Warranty Card   

To receive after-Sale service, have the following ready 
when you contact our branches.

1. Name of the product.

2. Model number of the product.

3. The area of problem.

4. Phone number and address at     

which you can be contacted.

Summary of Contents for KIV-212

Page 1: ...ality improvement PRODUCT MODEL DATE PURCHASED WARRANTY PERIOD AGENCY ADDRESS KOCOM Warranties the original purchaser of this product as follows 1 This product is produced under strict quality control and inspection procedures 2 If this product breaks down during proper use as a result of product defect KOCOM will repair it within one year from date of purchase free of charge 3 The following cases...

Page 2: ...2 3 ...

Page 3: ...4 5 ...

Page 4: ...between indoors and outdoors and also eliminates moisture and condensation on door camera window Stop up P V C pipe using adiabatic substances to prevent air circulation MIC Sending the voice to lobby phone guard phone camera and other equipment connecting to in house line Power LED Communication Button When receiving the call signal from interlocked outside equipment user can communicate with it ...

Page 5: ...tallation Bottom base of One hall Box Basic Installation method of Monitor When system is attached to 1 rectangular switch box Standard Height of Monitor Standard height of monitor is ranged 1 450 1 500 from bottom to the center of monitor screen For installation avoid the places where there is any excessive humidity magnetic force dangerous chemicals direct ray of sun and any places near a heater...

Page 6: ...is used 300m Monitor 0 C 50 C Power Source Voltage of Operating Power Lobby Guardroom In house Call Signal Monitoring of Front Door Camera Lobby Phone s Lobby Monitoring Function Call Method Communication Method Image Maintenance Time Number of Wiring Dimensions Communication Distance Guaranteed Operation Temperature KC C60 KC MC35 Front Door Camera KIV 212 Monitor KIV D212 Monitor Component Monit...

Page 7: ...ration or poor communication quality please carefully conduct wiring work When connecting a wiring chord to a terminal loosen screw insert the end of the chord into the bottom part of screw and tighten the screw When fixing wiring chord use stapler not to cause damage to the chord When using existing wiring please be cautious not to cause disconnection and short circuit Wiring for multi houses apa...

Page 8: ...ommunication button By doing so monitor screen is turned on and user can keep communicating with the visitor While communicating with the visitor if user presses the door open button house front door will be opened Monitoring of Front Door Situations 1 Monitoring for Camera 1 If pressing the front door button once on the monitor the image from camera 1 port is displayed on the monitor screen 2 Mon...

Page 9: ...guardroom phone is busy the image from lobby phone common gate camera is not displayed 2 After 8 sec of lobby common gate monitoring the monitor screen is automatically turned off 3 In house the users can see the image and hear the voice from the lobby phone common gate camera for 8 sec 4 This lobby common gate monitoring function is only available with 10 key type of KLP 100 KLP P100 KLP C100 lob...

Page 10: ... Communication with guardroom maintains for 3 minutes When communication is ended device returns to standby mode Stand by House Number Call state Communication state Stand by Stand by Guard Master Number Call state Communication state Stand by Password Change Password change function is only available during the call with house Pressing 0 0 during the call with house is displayed Input new passwor...

Page 11: ...Specification Within DC 12V 300mA Functional specifications may be changed according to the specifications of installed products The numbers are the setting number when the switch is put to ON 1 If DIP SWITCH from 1 to 12 is put to ON the numbers of DIP SWITCH will be summed up ex1 If the switches 1 and 2 are put to ON the setting number becomes 1 2 3 ex2 If the switches 1 and 3 are put to ON the ...

Page 12: ...the result is 8 200 208 the house No 208 In this case DIP SWITCH 1 3 10 is put to ON the result is 1 4 800 805 the house No 805 In this case DIP SWITCH 2 7 11 12 is put to ON the result is 2 100 1000 2000 3102 the house No 3102 ex8 ex9 ex10 In this case DIP SWITCH 1 10 11 12 is put to ON the result is 1 800 1000 2000 3801 the house No 3801 In this case DIP SWITCH 2 6 7 11 12 is put to ON the resul...

Page 13: ... switches excessive impact on DIP switches may cause abnormal or erroneous operation of device 11 9 7 5 3 1 A 12 10 8 6 4 2 B House Setting No The numbers are the setting number when the switch is put to ON 1 If DIP SWITCH from 1 to 12 is put to ON the numbers of DIP SWITCH will be summed up ex1 If the switches 1 and 2 are put to ON the setting number becomes 1 2 3 ex2 If the switches 1 and 3 are ...

Page 14: ...999 ex4 To set the house No 1203 In this case DIP SWITCH 1 4 5 8 9 12 is put to ON the result is 1 8 10 80 100 800 999 the house No 999 In this case DIP SWITCH 1 2 11 12 is put to ON the result is 1 2 400 800 1203 the house No 1203 ...