background image

CSM_K3HB-C_DS_E_15_1

1

Up/Down Counting Pulse Indicator

K3HB-C

Measure High-speed Up/down Pulses with this 
Up/down Pulse Meter.

• Visual conf0rmation of judgement results through display colors that 

switch between red and green. 

*

1

• Perfect for Measuring Rotary Encoder and ON/OFF Pulse Signals at High 

Speed 

Cumulative pulse input is 50 kHz, quadrature pulse inputs are 25 kHz, and up/
down pulse inputs are 30 kHz.

Note:

No-voltage contacts of up to 30 Hz are supported.

• The count value can be converted to any value.

The length equivalent for any pulse can be set to any desired value. This is 
effective for feed amount and position monitor displays.

• DeviceNet models added to the series. 

*

2

*1

Visual confirmation of judgement results is not supported on models that do not have an 
output or models that do not support DeviceNet.
You can change the display color by setting it, but you cannot switch it based on the judgement results.

*2

DeviceNet models have a depth of 97 mm.

Model Number Structure

Model Number Legend

Base Units and Optional Boards can be ordered individually or as sets.

Note:

The following combinations are not possible.

• Communications (FLK

@

A) + DeviceNet (DRT)

• Communications (FLK

@

A) + BCD output (BCD)

• Linear current/voltage (L

@

A) + DeviceNet (DRT)

Refer to 

Safety Precautions for All Digital Panel 

Meters

.

Base Units

1. Input Sensor Code

NB: NPN input/voltage pulse input

5. Supply Voltage

100-240 VAC: 100 to 240 VAC
24 VAC/VDC: 24 VAC/VDC

Optional Board

Sensor Power Supply/Output Boards

Relay/Transistor Output Boards

Event Input Boards

Base Units with Optional Boards

2. Sensor Power Supply/Output Type Code

None:

None

CPA:

Relay output (PASS: SPDT) + Sensor power supply

(12 VDC±10%, 80 mA) (See note 1.)

L1A:

Linear current output (0 to 20 or 4 to 20 mA DC) + Sensor power supply

(12 VDC±10%, 80 mA) (See note 2.)

L2A:

Linear voltage output (0 to 5, 1 to 5, or 0 to 10 VDC) + Sensor power supply

(12 VDC±10%, 80 mA) (See note 2.)

A:

Sensor power supply (12 VDC ±10%, 80 mA)

FLK1A: Communications (RS-232C) + Sensor power supply

(12 VDC±10%, 80 mA) (See note 2.)

FLK3A: Communications (RS-485) + Sensor power supply

(12 VDC±10%, 80 mA) (See note 2.)

Note: 1.

CPA can be combined with relay outputs only.

2.

Only one of the following can be used by each Digital Indicator: RS-232C/
RS-485 communications, a linear output, or DeviceNet communications.

3. Relay/Transistor Output Type Code

None: None
C2:

Relay contact (HH/H/LL/L: SPST-NO each)

T1:

Transistor (NPN open collector: HH/H/PASS/L/LL)

T2:

Transistor (PNP open collector: HH/H/PASS/L/LL)

BCD

:BCD  transistor output (NPN open collector: HH/H/PASS/L/LL)

DRT: DeviceNet (See note 2.)

 A Special BCD Output Cable (sold separately) is required.

4. Event Input Type Code

None: None
1:

5 inputs (M3 terminal block), NPN open collector

2:

8 inputs (10-pin MIL connector), NPN open collector

3:

5 inputs (M3 terminal block), PNP open collector

4:

8 inputs (10-pin MIL connector), PNP open collector

For the most recent information on models that have been certified for 
safety standards, refer to your OMRON website.

1

5

K3HB-C 

@

2

K33-

@

3

K34-

@

4

K35-

@

1

2 3 4

5

K3HB-C

@

-

@@@

 

Summary of Contents for K3HB-C Series

Page 1: ...o 240 VAC 24 VAC VDC 24 VAC VDC Optional Board Sensor Power Supply Output Boards Relay Transistor Output Boards Event Input Boards Base Units with Optional Boards 2 Sensor Power Supply Output Type Cod...

Page 2: ...at 0 4 mA max Max applied voltage 30 VDC max OFF leakage current 0 1 mA max Reset input Bank input Output ratings depends on the model Relay output 250 VAC 30 VDC 5 A resistive load Mechanical life e...

Page 3: ...r relay outputs 3 times each in 3 axes 6 directions Weight Approx 300 g Base Unit only Degree of protection Front panel Conforms to NEMA 4X for indoor use equivalent to IP66 Rear case IP20 Terminals I...

Page 4: ...number of people entering an area F2 Phase dif ferential in puts This function is normally used when connected to an incremental rotary encoder The count is incremented on the falling edge of input B...

Page 5: ...utputs 250 pulses for a 0 5 m feed the length per pulse 500 mm 0 5 m 250 2 1 The prescale value for the K3HB C is set using the mantissa X exponent Y so the prescale value 2 0000 10 X 2 000 and Y 00 2...

Page 6: ...0 mA 0 to 5 V 1 to 5 V 0 to 10 V Allowable load impedance 500 max 5 k min Resolution Approx 10 000 Output error 0 5 FS 0 5 FS 0 15 V for 1 V or less and no output for 0 V Item Type RS 232C RS 485 Comm...

Page 7: ...s Combination of multi drop and T branch connections for trunk and drop lines Baud rate DeviceNet 500 250 or 125 Kbps automatic follow up Communications media Special 5 wire cable 2 signal lines 2 pow...

Page 8: ...VAC VDC A1 A2 HH H L LL PASS BCD NPN Open Collector BCD Applicable Connector Sold separately HDR E50MAG1 HONDA TSUSHIN KOGYO CO LTD Special Cable Sold separately K32 BCD OMRON HDR E50MAG1 with 0 3 m...

Page 9: ...label abbreviates COMPENSATION to CMP Note E3 and E6 as well as B5 are internally connected COM E3 E6 E2 E5 700 510 12 V E3 E6 E1 E4 10 k 700 510 12 V NPN Input Model NPN input section Voltage pulse i...

Page 10: ...120 100 80 60 40 20 0 20 10 0 10 20 30 40 50 60 Ambient temperature C Maximum current mA 1 Keys Micro computer Waveform shaping circuit Waveform shaping circuit Drive circuit Indications EEPROM Drive...

Page 11: ...min between DATA VALID turning OFF and the REQUEST signal See note See note See note The K3HB BCD output model has an open collector output so wired OR connection is possible Programmable Controller C...

Page 12: ...ameter names and error names Displays SV and monitor values Displays the position of the PV with respect to a desired scale Comparative output status indicators Level bank display Status indicators Di...

Page 13: ...t the angles shown in the following diagram Character Size for Main Display mm Terminal M3 Terminal Cover Accessory Terminal cover included PV display SV display 14 2 4 9 3 5 7 6 96 48 1 3 12 112 100...

Page 14: ...y protection restricts level or parameter changes using the keys to prevent unintentional key operations and malfunctions Outputs Zone and level comparative output patterns can be selected for compara...

Page 15: ...to RUN level when there are no key operations e g max min switching bank settings using keys Other Switch between 8 comparative value banks using the keys on the front panel or external inputs A set...

Page 16: ...ther in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity...

Page 17: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Omron K3HB CNB 24VAC VDC K3HB CNB 100 240VAC...

Reviews: