K3HB-C

14

Main Functions

Main Functions and Features

Measurement

The K3HB-R has the following six functions for receiving and 
displaying input pulses.

F1: Rotation (rpm)/circumferential speed

F2: Absolute ratio

F3: Error ratio

F4: Rotational difference

F5: Flow rate ratio

F6: Passing time

The K3HB-P has the following six functions for receiving and 
displaying input pulses.

F1: Passing speed

F2: Cycle

F3: Time difference

F4: Time band

F5: Measuring length

F6: Interval

The K3HB-C has the following three functions for receiving and 
displaying input pulses.

F1: Individual inputs

F2: Phase differential inputs

F3: Pulse counting input

Filters

Specify the types of sensor connected to input A and input B.

Compensation

The display can be changed to a preset compensation value using 
the compensation input.

Key Operations

The present measurement value can be used as a scaling value.

Key protection restricts level or parameter changes using the keys to 
prevent unintentional key operations and malfunctions.

Outputs

Zone and level comparative output patterns can be selected for 
comparative outputs. 

Delays turning OFF comparatives for a set period. This can be used 
to provide sufficient time to read the comparative output ON status 
when the comparative result changes at short intervals. 

Turns ON the comparative output for a specific time.

Reverses the output logic of comparative results.

Output operation can be checked without using actual input signals 
by using the keys to set a test measurement value.

A current or voltage proportional to the change in the measurement 
value can be output.

The comparison outputs can be kept OFF until the measurement 
value enters the PASS range.

Function

func

Input Types

in-ta

in-tb

in-ta

Compensation

compn

,

 com-p

Teaching

Key Protection

Comparative Output Pattern

out-p

 

Output OFF Delay

off-d

 

Shot Output

shot

 

Output Logic

out-n

 

Output Test

test

 

Linear Outputs

lset.c

lset.v

lset.h

lset.l

 

Standby Sequence

stdby

 

Summary of Contents for K3HB-C Series

Page 1: ...o 240 VAC 24 VAC VDC 24 VAC VDC Optional Board Sensor Power Supply Output Boards Relay Transistor Output Boards Event Input Boards Base Units with Optional Boards 2 Sensor Power Supply Output Type Cod...

Page 2: ...at 0 4 mA max Max applied voltage 30 VDC max OFF leakage current 0 1 mA max Reset input Bank input Output ratings depends on the model Relay output 250 VAC 30 VDC 5 A resistive load Mechanical life e...

Page 3: ...r relay outputs 3 times each in 3 axes 6 directions Weight Approx 300 g Base Unit only Degree of protection Front panel Conforms to NEMA 4X for indoor use equivalent to IP66 Rear case IP20 Terminals I...

Page 4: ...number of people entering an area F2 Phase dif ferential in puts This function is normally used when connected to an incremental rotary encoder The count is incremented on the falling edge of input B...

Page 5: ...utputs 250 pulses for a 0 5 m feed the length per pulse 500 mm 0 5 m 250 2 1 The prescale value for the K3HB C is set using the mantissa X exponent Y so the prescale value 2 0000 10 X 2 000 and Y 00 2...

Page 6: ...0 mA 0 to 5 V 1 to 5 V 0 to 10 V Allowable load impedance 500 max 5 k min Resolution Approx 10 000 Output error 0 5 FS 0 5 FS 0 15 V for 1 V or less and no output for 0 V Item Type RS 232C RS 485 Comm...

Page 7: ...s Combination of multi drop and T branch connections for trunk and drop lines Baud rate DeviceNet 500 250 or 125 Kbps automatic follow up Communications media Special 5 wire cable 2 signal lines 2 pow...

Page 8: ...VAC VDC A1 A2 HH H L LL PASS BCD NPN Open Collector BCD Applicable Connector Sold separately HDR E50MAG1 HONDA TSUSHIN KOGYO CO LTD Special Cable Sold separately K32 BCD OMRON HDR E50MAG1 with 0 3 m...

Page 9: ...label abbreviates COMPENSATION to CMP Note E3 and E6 as well as B5 are internally connected COM E3 E6 E2 E5 700 510 12 V E3 E6 E1 E4 10 k 700 510 12 V NPN Input Model NPN input section Voltage pulse i...

Page 10: ...120 100 80 60 40 20 0 20 10 0 10 20 30 40 50 60 Ambient temperature C Maximum current mA 1 Keys Micro computer Waveform shaping circuit Waveform shaping circuit Drive circuit Indications EEPROM Drive...

Page 11: ...min between DATA VALID turning OFF and the REQUEST signal See note See note See note The K3HB BCD output model has an open collector output so wired OR connection is possible Programmable Controller C...

Page 12: ...ameter names and error names Displays SV and monitor values Displays the position of the PV with respect to a desired scale Comparative output status indicators Level bank display Status indicators Di...

Page 13: ...t the angles shown in the following diagram Character Size for Main Display mm Terminal M3 Terminal Cover Accessory Terminal cover included PV display SV display 14 2 4 9 3 5 7 6 96 48 1 3 12 112 100...

Page 14: ...y protection restricts level or parameter changes using the keys to prevent unintentional key operations and malfunctions Outputs Zone and level comparative output patterns can be selected for compara...

Page 15: ...to RUN level when there are no key operations e g max min switching bank settings using keys Other Switch between 8 comparative value banks using the keys on the front panel or external inputs A set...

Page 16: ...ther in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity...

Page 17: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Omron K3HB CNB 24VAC VDC K3HB CNB 100 240VAC...