background image

Motor Protection Circuit Breaker

 

J7MN

I-3

L

o

w vol

tage 

switch

 gear

Accessories

Description

Mounting 

place

Max. per 

MPCB

Contacts

Rated Operating 

Current

Type

AC15

AC1

24 V

240 V 240 V

NO

NC

A

A

A

Transverse Auxiliary

Contact block

Front

1

1

1

3

2

5

J77MN-11F

2

-

3

2

5

J77MN-20F

-

2

3

2

5

J77MN-02F

Side Auxiliary

Contact block

Left hand 
side

1

1

1

6

4

10

J77MN-11S

2

-

6

4

10

J77MN-20S

-

2

6

4

10

J77MN-02S

Any Trip Alarm

Signalling switch

Left hand 
side

1

1

1

6

4

10

J77MN-TA-11S

Short circuit Trip Alarm

Signalling switch

Left hand 
side

1

1

1

6

4

10

J77MN-T-11S

Description

Mounting 

place

Max. per 

MPCB

Rated voltages

Type

Undervoltage Release

Trips the circuit-breaker when 
the voltage is interrupted. Pre-
vents the motor from being re-
started accidentally when the 
voltage is restored, suitable for 
EMERGENCY STOP acc. to 
VDE 0113

Right hand 
side

1

24 V 50 Hz, 28 V 60 Hz

J77MN-U-24

110 - 127 V 50 Hz, 120 V 60 Hz

J77MN-U-110

220 - 230 V 50 Hz, 240 - 260 V 60 Hz

J77MN-U-230

240 V 50 Hz, 277 V 60 Hz

J77MN-U-240

380 - 400 V 50 Hz, 440 - 460 V 60 Hz

J77MN-U-400

415 - 440 V 50 Hz, 460 - 480 V 60 Hz

J77MN-U-415

Shunt Release

Trips the circuit-breaker when 
the release coil energized.

Right hand 
side

1

24 V 50 Hz, 28 V 60 Hz

J77MN-S-24

110 - 127 V 50 Hz, 120 V 60 Hz

J77MN-S-110

220 - 230 V 50 Hz, 240 - 260 V 60 Hz

J77MN-S-230

240 V 50 Hz, 277 V 60 Hz

J77MN-S-240

380 - 400 V 50 Hz, 440 - 460 V 60 Hz

J77MN-S-400

415 - 440 V 50 Hz, 460 - 480 V 60 Hz

J77MN-S-415

Description

Type

Enclosure

Plastic enclose with rotary operating mechanism, lockable space for aux. c release

J77MN-PF-3R

Enclose with rotary operating mechanism yellow - red, lock space for aux. c release

J77MN-PFC-3R

Door-coupling rotary

The door-coupling rotary operating mechanisms consist of 
a knob, a coupling driver and an extension shaft (5 mm x 
5 mm, lenght 330 mm). The door-coupling rotary operating 
mechanisms are designed for degree of protection IP 65. 
The door locking device prevents accidental opening of the 
cubicle door in the ON position of the circuit-breaker. The 
OFF position can be locked with up to 3 padlocks.

Mechanism black, with supporting 
bracket

J77MN-DC-B

Mechanism; red/yellow, with sup-
porting bracket

J77MN-DC-RY

Link modules

Mechanical and electrical connection between Motor Pro-
tection Circuit Breaker and Contactor. Up-to max. 32 A.

Mini Motor Contactor J7KNA

J77MN-VKA-3

Motor Contactor J7KN

J77MN-VKN-3

Motor Contactor J7KNG

J77MN-VKG-3

Electrical connection between Motor Protection Circuit 
Breaker and Contactor. 

Up-to 32 A

J77MN-VD-3

Up-to 63 A

J77MN-VD-6
J77MN-VDG-6

Up-to 100 A

J77MN-VD-9

Summary of Contents for J7MN -

Page 1: ...lease Shunt release Three phase busbar system Moulded plastic enclosures Door coupling rotary mechanisms Insulated Link modules Ordering Information Model Number Legend 1 Motor Protection Circuit Brea...

Page 2: ...4 22 286 15 J7MN 3P 22 26 11 18 26 338 15 J7MN 3P 26 32 15 22 32 416 15 J7MN 3P 32 0 16 0 10 0 16 2 1 100 J7MN 3R E16 0 25 0 06 0 16 0 25 3 3 100 J7MN 3R E25 0 4 0 09 0 25 0 4 5 2 100 J7MN 3R E4 0 63...

Page 3: ...24 V 50 Hz 28 V 60 Hz J77MN S 24 110 127 V 50 Hz 120 V 60 Hz J77MN S 110 220 230 V 50 Hz 240 260 V 60 Hz J77MN S 230 240 V 50 Hz 277 V 60 Hz J77MN S 240 380 400 V 50 Hz 440 460 V 60 Hz J77MN S 400 41...

Page 4: ...mm In 64 A 1 1 The sum of all added currents per module must not exeed the above mentioned nominal currents for 2 units J7MN 3P J7MN 3R 1 J75 CPM 2 45 6 for 3 units 1 J75 CPM 3 45 6 for 4 units 1 J75...

Page 5: ...3 7 5 J7KN 18 J77MN VKN 3 Not Needed J7MN 3P J7MN 3R J7KN 18 xx VKN3 Included J7KNG 18 xx D J77MN VKG 3 11 J7KN 22 J77MN VKN 3 Not Needed J7MN 3P J7MN 3R J7KN 22 xx VKN3 Included J7KNG 22 xx D J77MN...

Page 6: ...100 100 100 100 100 100 100 1 100 100 100 100 100 100 100 100 100 100 1 6 100 100 100 100 100 100 100 100 3 3 20 2 5 100 100 100 100 100 100 50 100 3 3 35 4 100 100 100 100 100 38 50 15 38 50 3 3 40 6...

Page 7: ...R per conducting path P I 3 In 26 up to 63 A 12 6 W In up to 63 A W 11 9 W In 75 up to 100 A 15 W Shock resistance acc to IEC 68 Part 2 27 25 g Degree of protection acc to IEC 60 529 IP 20 Shock hazar...

Page 8: ...ty 3 VA 1 2 W Response voltage trip 0 7 to 1 1 Us V Short circuit protection for auxiliary and control circuits Fuse gL gG 10 A Miniature circuit breaker C characteristic 6 A Conductor cross sections...

Page 9: ...0 10 10 10 10 10 10 10 kA Motor load 1 phase 115 V 1 8 1 4 1 3 1 2 1 2 1 11 2 2 2 HP 230 V 1 10 1 6 1 3 1 2 1 11 2 2 3 3 5 5 HP Motor load 3 phase 200 V 1 2 3 4 1 2 2 3 3 5 71 2 71 2 HP 230 V 1 3 1 2...

Page 10: ...AC are practically short circuit proof at this voltage as higher short circuit currents are not usually encountered at the instal lation point Back up fuses are only necessary if the short circuit cu...

Page 11: ...690 mm 30 30 30 30 50 inch 1 18 1 2 1 18 1 18 2 Height of arcing spaces clearance from earthed parts at Ue V 240 415 460 525 690 mm 50 50 50 50 50 inch 2 2 2 2 2 Height of arcing spaces clearance fro...

Page 12: ...77MN DC 1 Max for shackle diameter for padlock 8 mm In the interest of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millim...

Reviews: