background image

Mini Contactor Relays 4-pole

 

J7KNA-AR

11

Engineering data and Characteristics

Mini Contactor Relays

Data according to IEC 947-5-1, VDE 0660, EN 60947-5-1

AC

DC

DC + Diode

Auxiliary Contacts

Type

J7KNA-AR...

J7KNA-AR...D

J7KNA-AR...VS

J73KN-A...

Rated insulation voltage U

V AC 690

*1

*1) Suitable at 690V for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): U

imp

 = 8kV.

Data for other conditions on request.

690

*1

690

*1

 690

*1

Thermal rated current I

th

 to 690V

Ambient temperature

40°C

A

10

10

10

10

60°C

A

6

6

6

6

Power loss 

per pole

at I

th

W

0.5

0.5

0.5

0.5

Utilization category AC15

Rated operational current I

e

220-240V

A

3

3

3

3

380-415V

A

2

2

2

2

440V

A

1.6

1.6

1.6

1.6

500V

A

1.2

1.2

1.2

1.2

660-690V

A

0.6

0.6

0.6

0.6

Utilization category DC13

Rated operational current I

e

60V

A

2

2

2

2

110V

A

0.4

0.4

0.4

0.4

220V

A

0.1

0.1

0.1

0.1

Maximum ambient temperature

Operation

open

°C

-40 to +60 (+90)

*2

*2) With reduced control voltage range 0.9 up to 1.0 x U

s

 and with reduced thermal rated current I

th

 to I

e

/AC15

enclosed

°C

-40 to +40

Storage

°C

-40 to +90

Short circuit protection

short-circuit current 1kA,
contact welding not accepted

max. fuse size

gL (gG)

A

20

20

20

20

Power consumption of coils

AC operated

inrush

VA

25

-

-

-

sealed

VA

4 - 5

-

-

-

W

1.2

-

-

-

DC operated

inrush

W

-

2.5

2.5

-

sealed

W

-

2.5

2.5

-

Operation range of coils

in multiples of control voltage U

s

0.85 - 1.1

0.8 - 1.1

0.8 - 1.1

-

Switching time 

at control voltage U

s

 ±10%

*3,*4

*3) Summary switching time = release time + arc duration
*4) Release time of NC make time of NO increase when suppressor units for voltage peak protection are used (Varistor, RC-units, Diode units).

AC operated

make time

ms

15 - 25

-

-

-

release time

ms

8 - 25

-

-

-

arc duration

ms

10 -15

-

-

-

DC operated

make time

ms

-

15 - 19

15 - 19

-

release time

ms

-

8 - 25

8 - 25

-

arc duration

ms

-

10 -15

10 -15

-

Cable cross-section

all connectors

solid

mm² 0.75 - 2.5

0.75 - 2.5

0.75 - 2.5

0.75 - 2.5

flexible

mm² 0.75 - 2.5

0.75 - 2.5

0.75 - 2.5

0.75 - 2.5

flexible with multicore cable end

mm² 0.5 - 1.5

0.5 - 1.5

0.5 - 1.5

0.5 - 2.5

Clamps per pole

2

2

2

2

solid or stranded

AWG 18 - 14

18 - 14

18 - 14

18 - 14

Summary of Contents for J7KNA-AR

Page 1: ...22 2 NO 2 NC 31 3 NO 1NC 40 4 NO 0NC 4 Coil voltage AC operated 24 AC24V 50 60Hz 48 AC48V 50Hz 110 AC110 115V 50Hz AC120 125V 60Hz 230 AC220 230V 50Hz AC240V 60Hz 240 AC230 240V 50Hz 400 AC380 400V 50Hz AC440V 60Hz 415 AC400 415V 50Hz 550 AC525 550V 50Hz AC600V 60Hz Coil voltage DC operated 24D DC24V 48D DC48V 60D DC60V 110D DC110V 125D DC125V 24VS DC24V with diode 48VS DC48V with diode 110VS DC11...

Page 2: ...il voltages see page 10 DC Solenoid Operated Contacts Distinc Number acc to DIN EN 50011 Ratings Thermal Rated Current Ith A Type Pack pcs Weight kg pc NO NC AC15 230V A 400V A Coil voltage 24V DC 2 5W 4 pole With Screw Terminals 4 40E 3 2 10 J7KNA AR 40 24D VS 1 10 0 19 3 1 31E 3 2 10 J7KNA AR 31 24D VS 1 10 0 19 2 2 22E 3 2 10 J7KNA AR 22 24D VS 1 10 0 19 1 with built in coil suppressor diode ze...

Page 3: ... 1 1 33Y 3 3 J73KN A 02 0 2 24Y 2 4 J73KN A 40 4 0 62Y 6 2 J73KN A 22 2 2 44Y 4 4 DC Solenoid Operated Wiring Diagrams Distinc Number acc to DIN EN 50011 Auxiliary Contact Blocks Contactor Relay with Auxiliary Contact Type NO NC Block Distinc Number according to DIN EN 50011 NO NC 4 pole With Screw Terminals 40E J73KN A 11 1 1 51E 5 1 Preferable combinations with distinctive letter E according to ...

Page 4: ...4 60 90 90 95 100 105 90 95 100 105 95 95 100 105 110 95 100 105 110 100 100 110 115 100 105 110 115 105 105 110 115 120 105 110 115 120 110 110 115 120 125 110 115 120 125 200 200 210 220 195 205 210 220 Suffix Voltage Marking Rated Control Voltage Us to contactor type e g at the coil range for 50Hz 60Hz J7KNA AR 40 230 for 50Hz V for 60Hz V min V max V min V max V 210 205 215 220 230 205 215 220...

Page 5: ...ith reduced control voltage range 0 9 up to 1 0 x Us and with reduced thermal rated current Ith to Ie AC15 enclosed C 40 to 40 Storage C 40 to 90 Short circuit protection short circuit current 1kA contact welding not accepted max fuse size gL gG A 20 20 20 20 Power consumption of coils AC operated inrush VA 25 sealed VA 4 5 W 1 2 DC operated inrush W 2 5 2 5 sealed W 2 5 2 5 Operation range of coi...

Page 6: ...for use on a capability of delivering not more than rms A V Rated voltage V AC 600 600 Auxiliary Contacts cULus heavy pilot duty AC A600 A600 standard pilot duty DC Q600 Q600 AC and DC operated with screw terminals Auxiliary Contact Blocks J7KNA AR J73KN A In the interest of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS Cat No J04E ...

Reviews: