Functions of Input Signals

 

 

Output Modes in Both Counter and Timer Operations

 

        Sustained control output                                                          One-shot control output, set to 0.5 second

Input type

Counter output

Signal high

Signal low

No-voltage

Contact

The contact turns ON

The contact turns OFF

Solid-state

The open collector transistor is in the ON state

The transistor is in the OFF state

Voltage

Both

Input signal voltage level is 5 to 30 V

Input signal voltage level is 0 to 2 V

Input

Counter mode A
(command input)

Counter mode B
(individual input)

Counter mode C
(phase difference)

Timer operation

Count input 1

Count input: 
The count value is increased 
by one when count input 2 
(CP2) voltage goes low. The 
count value is decreased by 
one when count input 2 (CP2) 
voltage goes up.

Addition count input

The count value is increased by 
one when phase of count input 
2 (CP2) is delayed with respect 
to phase of count input 1 (CP1).

The count value is decreased 
by one when phase of count 
input 2 (CP2) is ahead with 
respect to phase of count input 
1 (CP1).

Start input

Count input 2

Addition/subtraction control

Subtraction count input

Gate input

 

Output Mode N

 

  Present value display and outputs are 

maintained until reset.

 

Output Mode F

 

  Present value runs continuously. Outputs 

are maintained until reset.

 

Output Mode C

 

  Present value is placed in reset start status 

as soon as preset count is reached; the preset is not actually 
displayed. Outputs are one-shot, fixed at 0.5 second, and 
operate repeatedly.

 

Output Mode R

 

  Present value display returns to reset start 

status after expiration of one-shot time period. Outputs are 
one-shot, fixed at 0.5 second, and operate repeatedly.

Reset

Preset

Digital
display
             0

Control
output

Reset

Preset

Digital
display
             0

Control
output

Reset

Preset

Digital
display
             0

Control
output

Reset

Preset

Digital
display
             0

Control
output

Summary of Contents for H8CA-S Series

Page 1: ...input modes and four operating modes are selectable Timer time limit operation integrating operation Four operating modes are selectable Backup power supply for memory protection Provided Approx 10 y...

Page 2: ...60 Hz DC 12 to 120 VDC 20 max permissible ripple Operating voltage range 90 to 110 of rated voltage Power consumption See Note 1 Approx 2 2 VA at 240 VAC 50 Hz Approx 1 W at 120 VDC Max counting spee...

Page 3: ...bration Mechanical durability 10 to 55 Hz 0 75 mm 0 030 in double amplitude Malfunction durability 10 to 55 Hz 0 3 mm 0 012 in double amplitude Shock Mechanical durability approx 30 G Malfunction dura...

Page 4: ...ted if the minimums for A and B are not met In Counter Function Mode In Timer Function Mode Command Input Mode A Individual Input Mode B Phase Difference Input Mode C Count input 1 Count input 2 Digit...

Page 5: ...ne when phase of count input 2 CP2 is delayed with respect to phase of count input 1 CP1 The count value is decreased by one when phase of count input 2 CP2 is ahead with respect to phase of count inp...

Page 6: ...03 13 6 0 54 78 3 07 50 1 97 45 1 77 45 1 77 50 1 97 Note Recommended panel thickness is 1 to 3 2 mm Panel cutout conforms to DIN 43700 70 max 2 76 7 8 0 31 Eleven M3 5 x 7 5 sems 50 max 1 97 3 0 12...

Page 7: ...8 0 31 91 9 3 62 Panel Adapter for panel mounting Y92F 30 P3GA 11 back connecting socket 4 5 0 18 L 15 25 25 25 25 1 0 04 27 0 15 35 0 3 7 3 0 15 10 10 L Length 1 m PFP 100N 50 cm PFP 50N 1 m PFP 100...

Page 8: ...it The function input mode or output mode display will be blinking The Power OFF display will stop blinking when power comes ON Output display Input mode display Output mode display Reset key Advance...

Page 9: ...e N will stop blinking Always disconnect terminals 1 and 3 when finished selecting the function Values cannot be preset if terminals 1 and 3 are con nected 2 Selecting the timer function with sec and...

Page 10: ...r the power supply is ON or OFF Press the key until the desired digit begins blinking Press the key to set the desired value Continue pressing the and keys until the smallest digit has been set To com...

Page 11: ...C voltage is recommended when the counter is installed at a location where the input terminals are easily accessible Note When connecting external signal input contacts and tran sistors use a power su...

Page 12: ...ol output used as shown in the table below Reset Input Connection Voltage Input Type Type of control output Max counting speed of rated time Output delay time Contact output 30 cps Common to hours min...

Page 13: ...nput 2 Counts when turned ON Input 1 Input 2 Counts when turned ON Input 2 Input 1 A count signal is input when turned ON 30 VDC max 30 VDC max Input 1 Input 2 A count signal is input when turned OFF...

Page 14: ...n a signal will be output when the new value is the same as the displayed value The front panel keys operate at a touch Do not press the keys with excessive force or tools such as a screwdriver Press...

Page 15: ...Y92F 30 adapter loosen the two screws of the adapter pry up the top and bottom hooks of the adapter and pull the H8CA S out from the front of the panel Caution The H8CA S has a built in lithium batter...

Reviews: