28
H7CX (Tachometer Function)
H7CX (Tachometer Function)
Output Allocation (
.323
)
When using H7CX-AU
@
models as 2-stage counter, each output
can be flexibly allocated to either stage 1 or 2.
Transistor output placed for SV1 and contact output for SV2 or
vice verce, as in the following table.
H7CX-AU/-AUD1
H7CX-AUSD1
Key Protect Level (
*7/3
)
Set the key protect level.
When the key-protect switch in set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by specify-
ing the key protect level (KP-1 to KP-5). The key protect indicator is lit while the key-protect switch is set to ON. Confirm the ON/OFF status
of the key-protect switch after the H7CX is mounted to the panel.
Note:
Changing mode to configuration selection mode (
+
1 s min.) or function setting mode (
3 s min.).
OUT1
OUT2
.%%
Transistor (12-13)
Contact (3, 4, 5)
.-
Contact (3, 4, 5)
Transistor (12-13)
OUT1
OUT2
.%%
Transistor (12-13)
Transistor with diode
(3, 4, 5)
.-
Transistor with diode
(3, 4, 5)
Transistor (12-13)
Level
Meaning
Details
Changing mode
(See note.)
Switching display
during operation
Reset key
Up/down key (Up key
for 6-digit models)
KP-1 (default setting)
No
Yes
Yes
Yes
KP-2
No
Yes
No
Yes
KP-3
No
Yes
Yes
No
KP-4
No
Yes
No
No
KP-5
No
No
No
No
ON
OFF
Note: Factory-set to OFF
Key protect indicator
(See note)
MODE
1
MODE