![background image](http://html1.mh-extra.com/html/omron/h7cx/h7cx_manual_741991027.webp)
30
H7CX (Tachometer Function)
H7CX (Tachometer Function)
■
Output Mode Settings
Output
mode
setting
Upper and
lower limit
(HI-LO)
Area
(AREA)
Condition
OUT1 set value
OUT2 set value
OUT1 set value
>
OUT2 set value
ON
condition
for OUT1
OUT1 set value
measurement value
OUT2 set value
OUT2 set value
measurement value
OUT1 set value
ON
condition
for OUT2
measurement value < OUT1 set value
or
measurement value > OUT2 set value
measurement value < OUT2 set value
or
measurement value > OUT1 set value
Upper
limit
(HI-HI)
Lower
limit
(LO-LO)
OUT1
OUT2
(Lower-limit) OUT1 set value
(Upper-limit) OUT2 set value
ON condition for OUT1: measurement value
OUT1 set value
ON condition for OUT2: measurement value
OUT2 set value
Measurement value
OUT1
OUT2
OUT1 set value
OUT2 set value
Measurement value
OUT1
OUT2
(Upper-limit) OUT1 set value
(Upper-limit) OUT2 set value
ON condition for OUT1: Measurement value
OUT1 set value
ON condition for OUT2: Measurement value
OUT2 set value
Measurement value
OUT1
OUT2
(Lower-limit) OUT1 set value
(Lower-limit) OUT2 set value
ON condition for OUT1: Measurement value
OUT1 set value
ON condition for OUT2: Measurement value
OUT2 set value
Measurement value