H5AN
Specifications
■
Ratings
Note:
Inrush current was measured within the range shown below.
■
Characteristics
Note:
This value denotes the average of the repeat accuracy, setting error, and variations due to voltage and temperature changes. It includes the
rise time of the power supply, and the operating time of the internal and output circuits.
Item
H5AN-4D/H5AN-4DM
Rated supply voltage
H5AN-4D:
100 to 240 VAC (50/60 Hz),
12 to 24, 48, or 100 VDC (permissible ripple: 20% max.)
H5AN-4DM: 100 to 240 VAC (50/60 Hz)
12 to 24 VDC (permissible ripple: 20% max.)
Operating voltage range
85% to 110% of rated supply voltage
Power consumption
Approx. 10 VA (at 240 VAC, 50 Hz), approx. 5 W (at 24 VDC)
Resetting system and gate
input
Reset by power-OFF: min. power OFF time: 0.5 s
External reset or gate (common to contact and solid-state inputs): min. reset input signal width: 0.02 s
One-shot output time
0.1 to 1 s (adjustable)
Control outputs
Contact output: SPDT, 3 A at 250 VAC, resistive load (cos
φ
= 1)
Solid-state output: Open collector, 100 mA max. at 30 VDC max.
Power supply for externally
connected components
12 VDC
±
10%, 80 mA (permissible ripple: 5% max.)
Peak value
Inr
ush current
Time
Measurement
time
Accuracy of operating time
±
0.01%
±
0.05 s max. (power OFF start),
±
0.005%
±
0.03 s max. (reset start) (see note)
Setting error
Influence of voltage
Influence of temperature
Insulation resistance
100 M
Ω
min. (at 500 VDC) (between current-carrying terminal and exposed non-current carrying metal
parts, between non-continuous contacts)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying metal parts)
750 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Vibration resistance
Destruction: 10 to 55 Hz with 0.75-mm double amplitude
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude
Shock resistance
Destruction: 300 m/s
2
(approx. 30G)
Malfunction: 100 m/s
2
(approx. 10G)
Ambient temperature
Operating:
–10
°
C to 55
°
C
Storage:
–25
°
C to 65
°
C
Ambient humidity
Operating: 35% to 85%
Life expectancy
Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h)
Electrical:
100,000 operations min. (3 A at 250 VAC, resistive load)
Approved standards
UL (File No. E41515), CSA (File No. LR22310)
Weight
Approx. 360 g