background image

H5AN

Specifications

Ratings

Note:

Inrush current was measured within the range shown below.

Characteristics

Note:

This value denotes the average of the repeat accuracy, setting error, and variations due to voltage and temperature changes. It includes the 
rise time of the power supply, and the operating time of the internal and output circuits.

Item

H5AN-4D/H5AN-4DM

Rated supply voltage

H5AN-4D:

100 to 240 VAC (50/60 Hz),
12 to 24, 48, or 100 VDC (permissible ripple: 20% max.)

H5AN-4DM: 100 to 240 VAC (50/60 Hz)

12 to 24 VDC (permissible ripple: 20% max.)

Operating voltage range

85% to 110% of rated supply voltage

Power consumption

Approx. 10 VA (at 240 VAC, 50 Hz), approx. 5 W (at 24 VDC)

Resetting system and gate 
input

Reset by power-OFF: min. power OFF time: 0.5 s
External reset or gate (common to contact and solid-state inputs): min. reset input signal width: 0.02 s

One-shot output time

0.1 to 1 s (adjustable)

Control outputs

Contact output: SPDT, 3 A at 250 VAC, resistive load (cos

φ

 = 1)

Solid-state output: Open collector, 100 mA max. at 30 VDC max.

Power supply for externally 
connected components

12 VDC

±

10%, 80 mA (permissible ripple: 5% max.)

Peak value

Inr

ush current

Time

Measurement 
time

Accuracy of operating time

±

0.01% 

±

0.05 s max. (power OFF start), 

±

0.005% 

±

0.03 s max. (reset start) (see note)

Setting error

Influence of voltage

Influence of temperature

Insulation resistance

100 M

Ω

 min. (at 500 VDC) (between current-carrying terminal and exposed non-current carrying metal 

parts, between non-continuous contacts)

Dielectric strength

2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying metal parts)
750 VAC, 50/60 Hz for 1 min (between non-continuous contacts)

Vibration resistance

Destruction: 10 to 55 Hz with 0.75-mm double amplitude
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude

Shock resistance

Destruction: 300 m/s

2

 (approx. 30G)

Malfunction: 100 m/s

2

 (approx. 10G)

Ambient temperature

Operating:

–10

°

C to 55

°

C

Storage:

–25

°

C to 65

°

C

Ambient humidity

Operating:  35% to 85%

Life expectancy

Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h)
Electrical:

100,000 operations min. (3 A at 250 VAC, resistive load)

Approved standards

UL (File No. E41515), CSA (File No. LR22310)

Weight

Approx. 360 g

http://www.ia.omron.com/

2

(c)Copyright OMRON Corporation 2008   All Rights Reserved. 

Summary of Contents for H5AN Series

Page 1: ...N F C R K P and Q are available Ordering Information Note 1 Specify both the model number and supply voltage when ordering 2 The Timer is supplied with two mounting fixtures Operation system Resetting system No of digits Backup power supply function for memory protection Model Time limit operation integrating operation Power OFF resetting excluding M external resetting manual resetting automatic r...

Page 2: ... for externally connected components 12 VDC 10 80 mA permissible ripple 5 max Peak value Inrush current Time Measurement time Accuracy of operating time 0 01 0 05 s max power OFF start 0 005 0 03 s max reset start see note Setting error Influence of voltage Influence of temperature Insulation resistance 100 MΩ min at 500 VDC between current carrying terminal and exposed non current carrying metal ...

Page 3: ...00 operations can be expected The minimum applicable load is 10 mA at 5 VDC P reference value Switching operations 10 3 7 segment LED display Front cover Time up indicator Reset input indicator Pushbutton switch for manual reset Internal unit fixing screw One shot time adjustment screw Rated time label affixing section when a rated time label of 99 min 59 s is affixed http www ia omron com 3 c Cop...

Page 4: ...et value and then returns to all zeroes In DOWN mode the digital display continues to up 9999 and then decrements 9998 9997 after reaching all zeroes The control output is held until a reset input is applied C The digital display returns to the initial setting once the set time has elapsed and the timer restarts the timing operation When the set time has elapsed the output signal is generated duri...

Page 5: ...the one shot time The timer repeats this cycle P For the digital display the value at the up is held during the one shot time however the timing operation of the timer returns to the initial setting when the set time has elapsed and the timer restarts the timing operation When the set time has elapsed the output signal is generated during the one shot time The timer repeats this cycle Q In UP mode...

Page 6: ...e solid state output when the set time has elapsed etc Set these switches for programming the desired functional specifications by referring to Positions and Functions of Specification Selector Switches Open the front cover The internal unit comes out by loosening the internal unit fixing screw http www ia omron com 6 c Copyright OMRON Corporation 2008 All Rights Reserved ...

Page 7: ...etting range 0 99 99 s 0 01 to 99 99 s 1 999 9 s 0 1 to 999 9 s 2 9999 s 1 to 9999 s 3 99 min 59 s 1 s to 99 min 59 s 4 999 9 min 0 1 to 999 9 min 5 99 hrs 59 min 1 min to 99 hrs 59 min 6 999 9 hrs 0 1 to 999 9 hrs 7 9999 hrs 1 to 9999 hrs 8 99 99 s Same as switch position 0 9 999 9 s Same as switch position 1 Switch position Operating mode Display mode 0 N DOWN display 1 F 2 C 3 R 4 K 5 P Note Sa...

Page 8: ...V 12 V 12 V Contact output Unused Power supply For DC power Terminal 1 Terminal 2 Unused Internally connected Do not use unused terminals for relaying Leave them open Note Specifications for 12 to 24 VDC 48 VDC and 100 VDC models are listed separately in this datasheet External power supply AC Power Supply DC Power Supply Load 3 See note When a Load Operates with Contact Output When a Load Operate...

Page 9: ...e solid state circuit V should be 13 to 30 V and the VCE S of the transistor should be less than 3 V the current that flows from either terminal 9 or 10 is approximately 10 mA Moreover it is essential that the circuit be ON for gate or reset input and OFF when there is no input Connection of a Power Supply for Externally Connected Components The H5AN has a built in power supply for externally conn...

Page 10: ...of Setting Actual Operating Time 4 When changing the set time while power is being supplied an inadequate push of the thumbwheel switches will display two numbers in one digital display window causing the operating time to drift widely Therefore press the thumb wheel switches surely Take particular care in the case when the other three digits are all zero since the improper setting of the fourth s...

Page 11: ...iable within a range to 0 1 to 1 s Mounting A Mounting Fixture is included with the H5AN Mount the Unit using the Mounting Fixture so that the Unit is secure and does not move Purchase of H5AN No Yes Yes Yes No No Is the timer equipped with memory protection Drawn out the internal unit from the case or switch off the power to reset the timer Selection of specifications Was the timer reset after po...

Page 12: ...atteries are likely to explode if incinerated Label to cover holes Fixture Sunken nut Specifications label In the interest of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 http www ia omron com 12 c Copyright OMRON Corporation 200...

Page 13: ...s subject to sulfidizing gas chloride gas or silicon gas The switching capacity for DC voltage loads is lower than that for AC voltage loads Timers with Non contact Outputs Short faults or open faults may occur due to destruction of the output element Do not use the Timer for a load that exceeds the rated output current Short faults or open faults may occur due to destruction of the output element...

Page 14: ...ot possible OMRON does provide special Timers with improved resistance to sulfidizing gas Ask your OMRON representative for details Power Supply Be sure that the voltage applied is within the specified range otherwise the internal elements of the Timer may be damaged Install a switch or circuit breaker that allows the operator to immediately turn OFF the power and label it to clearly indicate its ...

Page 15: ...s subject to sulfidizing gas chloride gas or silicon gas The switching capacity for DC voltage loads is lower than that for AC voltage loads Timers with Non contact Outputs Short faults or open faults may occur due to destruction of the output element Do not use the Timer for a load that exceeds the rated output current Short faults or open faults may occur due to destruction of the output element...

Page 16: ... may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate industry or government regulations Systems...

Reviews: