Solid-state Two-wired Timer
H3DS-X
B-41
Ti
m
e
rs
■
Characteristics
Connections
■
Block Diagram
■
I/O Functions
Accuracy of operating time
±
1% max. of FS (
±
1%
±
10 ms max. at 1.2-s range)
Setting error
±
10%
±
50 ms max. of FS
Reset time
0.1 s max.
Influence of voltage
±
0.5% max. of FS (
±
0.5%
±
10 ms max. at 1.2-s range)
Influence of temperature
±
5% max. of FS (
±
5%
±
10 ms max. at 1.2-s range)
Insulation resistance
100 M
Ω
min. at 500 VDC
Dielectric strength
Between current-carrying metal parts and exposed non-current-carrying metal parts: 2,000 VAC for 1 min
Impulse withstand voltage
3 kV (between power supply terminals)
4.5 kV (between current-carrying metal parts and exposed non-current-carrying metal parts)
Noise immunity
Square-wave noise generated by noise simulator (pulse width: 100 ns/1
µ
s, 1-ns rise)
±
1.5 kV (between power
supply terminals)
Static immunity
Malfunction: 4 kV
Destruction: 8 kV
Vibration resistance
Malfunction: 0.5-mm single amplitude at 10 to 55 Hz
Destruction: 0.75-mm single amplitude at 10 to 55 Hz
Shock resistance
Malfunction: 200 m/s
2
, 3 times each in 6 directions
Destruction: 300 m/s
2
, 3 times each in 6 directions
EMC
(EMI)
EN61812-1
Emission Enclosure:
EN55011 Group 1 class B
Emission AC Mains:
EN55011 Group 1 class B
Harmonic Current:
EN61000-3-2
Voltage Fluctuation and Flickering: EN61000-3-3
(EMS)
EN61812-1
Immunity ESD:
EN61000-4-2: 6 kV contact discharge (level 3)
8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves:
EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity Burst:
EN61000-4-4: 2 kV power port and output port (level 3)
1 kV control port with capacitive clamp (level 3)
Immunity Surge:
EN61000-4-5: 2 kV common mode (level 3)
1 kV differential mode (level 3)
Case color
Light gray (5Y7/1)
Degree of protection
IP30 (IP20 for terminal block)
Weight
Approx. 70 g
AC (DC)
input
Power supply
circuit
Oscillation
circuit
Zero setting
detection
circuit
Counting
circuit
Time scale/
unit selectors
Indicator
circuit
Output
circuit
Inputs
---
Outputs
Control output
Outputs are turned ON when the preset value is reached.