14
H3CR-A8/-A8S
Operating
mode
Timing chart
A:
ON-delay
Power
Output
t
Basic operation
Power
Output relay
(NC)
Output relay
(NO) (output
indicator)
Power
indicator
B
2
:
Flicker ON
start
Power
Output relay
(NC)
Output relay
(NO) (output
indicator)
Power
indicator
Power
Output
t
Basic operation
t
t
t
E:
Interval
Power
Output
t
Basic operation
Power
Output relay
(NC)
Power
indicator
Output relay
(NO) (output
indicator)
J:
One-shot
output
Power
Output relay
(NC)
Output relay
(NO) (output
indicator)
Power
indicator
Power
Output
t
Basic operation
1
±
0.6 s
(Fixed)
1
±
0.6 s
(Fixed)
1
±
0.6 s
(Fixed)
Summary of Contents for H3CR-A