background image

H2F-D

6

Safety Precautions

Refer to 

Safety Precautions for All Timers

.

 

!

WARNING

 

!

CAUTION

Precautions for Correct Use

Mounting

Panel Flush Mounting

1.

As illustrated at the right, 
bend the enclosed adapter in 
the direction of A, and then 
push part B in the direction of 
the arrow (i.e., toward the 
back of the panel cut).

2.

Once the adapter has been 
mounted, insert the Time 
Switch as illustrated at the 
right. Secure the Time Switch 
in two places using the 
enclosed screws (M3 

×

 16) 

tightened with a torque of 
0.58 N·m max.

3.

If the lead wire has been 
installed in front of the 
panel, place the Time 
Switch on part A of the 
adapter and push it in 
toward B. Then secure the 
Time Switch by tightening 
the screws as described in 
step 2.

Setting the Time

Turn the center knob clockwise to set 
the time. Product failure may occur if 
the knob is turned counterclockwise 
or the knob is turned while the 
triggers are being pressed.

Set the hour to the arrow at the 
upper left and set minutes to the 
arrow on the center knob.

The gold-colored triggers are for ON 
and the silver-colored triggers are for 
OFF. Securely push in the triggers 
with the wider part facing the outer 
part of the dial.

Insert the spare triggers into the 
holes at the lower right for storage.

Manual Switch

Models with SPST-NO Output

The output will turn OFF regardless of trigger settings when the 
manual switch at the lower left of the front panel is set to OFF. The 
output will turn ON regardless of trigger settings when the manual 
switch is set to ON. 
The output will turn ON and OFF according to the trigger settings 
when the manual switch is set to AUTO.

Models with SPDT Output

Load 1 (terminals 4 and 5) and load 2 (terminals 5 and 6) will both 
turn OFF when the manual switch at the lower left of the front panel 
is set to OFF.

The output will turn ON and OFF according to the trigger settings 
when the manual switch is set to AUTO. Load 1 (terminals 4 and 5) 
will turn ON and load 2 (terminals 5 and 6) will turn OFF when the 
manual switch is set to ON.

Check the output indicator when returning operation to AUTO. If the 
knob has been touched or the output indicator has changed 
because of vibration or shock, turn the knob, switch the output, and 
then return operation to AUTO.

Output Indicator and ON/OFF Switch 
Knob

The output indicator at the upper left of the front panel shows the 
output status when the manual switch is set to AUTO.
The output can also be manually 
switch ON or OFF by turning the 
knob clockwise (i.e., in the 
direction of the arrow). (This is 
possible only when the manual 
switch is set to AUTO.) 

Do not turn the ON/OFF switch knob when the manual switch is set 
to ON or OFF. Do not turn the Knob counterclockwise.

Minor injury may occasionally occur due to the battery 
bursting, igniting, or leaking. Never short-circuit the 
positive and negative terminals, disassemble the battery, 
deform it under pressure, or dispose of it in fire. 

Minor injury by electric shock may occasionally occur. Do 
not touch any of the terminals while power is being 
supplied. Be sure to mount the terminal cover after wiring.

Unexpected operation may occasionally occur.
Before changing times or other settings while power is 
being supplied, either turn OFF the power on the load 
side or set the output ON/OFF switch to OFF and confirm 
the safety of the system.

Fire may occasionally occur. Tighten the terminal screws 
to the rated torque.

Minor electric shock, fire, or product failure may 
occasionally occur. Do not allow metal fragments, copper 
wire scraps, or shavings from installation work to fall 
inside the Time Switch.

Minor electric shock, fire or product failure may 
occasionally occur. Never attempt to disassemble, 
modify, or repair the product or touch any of the internal 
parts.

Minor injury due to explosion may occasionally occur. Do 
not use the product where it is subject to flammable or 
explosive gas.

Panel

Adapter

B

A

A

Panel

Lead 

w

ire

Adapter

Time 
S

w

itch 

B

A

Summary of Contents for H2F-D

Page 1: ... models that have been certified for safety standards refer to your OMRON website Ordering Information Note Always use the Time Switch with the Y92S 42 Battery mounted Accessories Order Separately Control cycle Drive method Power interruption backup Power supply voltage Mounting method Flush mounting Surface mounting track mounting Control output SPST NO SPDT SPST NO SPDT Daily 24 hours Synchronou...

Page 2: ... to 24 VDC Control output 15 A at 250 VAC resistive load Ambient operating temperature 10 to 55 C with no icing Ambient operating humidity 35 to 85 Type Daily Item Synchronous motor Quartz motor Operating time deviation See note 1 Voltage influence and temperature influence 3 min max Setting error See note 2 3 min max Cyclic error 3 min max Power interruption backup time 180 h min See note 3 Insul...

Page 3: ... F Location of yellow lever Flush Mounting Surface Mounting DIN Track Mounting 72 72 45 mm H W D below faceplate 29 mm 95 72 50 mm H W D Panel Cutout Dimensions according to DIN 43700 Panel thickness 1 to 3 2 mm Note The mounting adapter and mounting screws are enclosed Mounting Screw Dimensions Adapter 68 0 7 0 68 0 7 0 17 5 27 5 Screw size M3 45 enclosed 61 0 2 Two M3 60 0 2 ...

Page 4: ...inal Nomenclature H2F D H2F DF H2F DC H2F DFC H2F DM H2F 30 H2F DMF Note On the H2F 30 12 to 24 VDC terminal number 2 is positive and terminal number 3 is negative H2F DMC H2F DMFC H2F 31 Note On the H2F 31 12 to 24 VDC terminal number 2 is positive and terminal number 3 is negative Mounting Holes ON OFF operation selector knob Dial rotation direction clockwise Manual switch Time setting knob Hole...

Page 5: ...ll units are in millimeters unless otherwise indicated 72 72 65 5 45 65 5 1 3 17 16 H2F D C H2F DM C H2F 30 Note The terminal screws are M3 5 72 72 95 2 2 50 9 6 6 29 H2F DF C H2F DMF C H2F 31 Note The terminal screws are M3 5 ...

Page 6: ... the manual switch is set to AUTO Load 1 terminals 4 and 5 will turn ON and load 2 terminals 5 and 6 will turn OFF when the manual switch is set to ON Check the output indicator when returning operation to AUTO If the knob has been touched or the output indicator has changed because of vibration or shock turn the knob switch the output and then return operation to AUTO Output Indicator and ON OFF ...

Page 7: ... excessive discharge if the H2F is left unused for an extended period with the battery mounted Be sure to remove the battery before storing the H2F Turn OFF the power supply before replacing the battery Use only the specified battery Y92S 42 The battery may leak or burst if any other battery is used possibly resulting in equipment damage or injury Other Precautions Always use a thermo switch on th...

Page 8: ...rther in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity with any standards codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product At Buyer s request Omron will provide applicable third party ce...

Reviews: