background image

Profinet Quick Start Guide 

Object of this guide 

This quick start guide is to allow a new user to PROFINET to attach PROFINET I/O to an Omron PLC 
and configure it to work. 

PROFINET products supported in this guide 

 

CJ1W-PNT21  PROFINET I/O Controller for CJx series PLC’s 

 

CS1W-PNT21  PROFINET I/O Controller for CJ1 series PLC’s 

 

GRT1-PNT 

PROFINET I/O Device – Smart Slice Bus coupler. 

 

Prerequisites 

  A PC computer with both Serial/USB and Ethernet (via PROFINET) connection to Omron 

PLC. 

 

Omron Cx-One V3.x or V4.x installed and up to date using Cx-One Auto Update utility.  Cx-
One suite contains the utility application ‘Cx-Configurator FDT’ for configuring and setting 
PROFINET devices. 

 PLC & I/O Controller and IO Devices (at least one) for configuration. 

I/O table on PLC should be created using Cx-Programmer. 

 

Network 

  It is recommended that the PROFINET network is ‘stand alone’.  This means not part of a 

larger network. 

 

The network speed must be 100MBaud.  Using a 10BaseT hub will not allow the network to 
operate correctly. 

  If you wish to use switching hubs as part of the network, we recommend that these are 

managed switches and of an industrial nature (e.g. Hirschmann). 

 

Connection of devices for configuration 

 

To configure the I/O controller – use a serial or USB connection from PLC to PC. 

  To configure the I/O devices – connect a network cable to the last I/O device (in case of 

GRT1-PNT). 

 

Typical Initial Connection diagram 

 

Serial for configuration of IO Controller

Ethernet for configuration of IO Devices

 

Rev 1.01 

 

1 of 8 

Summary of Contents for GRT1-PNT

Page 1: ...etting PROFINET devices PLC I O Controller and IO Devices at least one for configuration I O table on PLC should be created using Cx Programmer Network It is recommended that the PROFINET network is s...

Page 2: ...guration IO Controller connects to IO Devices Create a network using Cx Configurator FDT Using Cx Configurator FDT open the Device Catalogue and show PROFINET IO Highlight PROFINET IO Controller e g C...

Page 3: ...by searching for MAC addresses so IP does not need to be configured at this point Once all devices have been recognised the IO devices now require unique Device names set Use the Configure button and...

Page 4: ...t The IO Controller will respond with data in Unit Information The IO Controller Setup allows user to specify name and IP address for network leave as defaults if unsure IO Device Setup The IO Device...

Page 5: ...the configuration on the screen does not match that stored on Disk Before downloading Configuration changes to the IO Controller please make sure the project is saved disappear Download Configuration...

Page 6: ...e This should result in communication between IO Device s and IO Controller and hence cyclic IO exchange Where is my data Data is mapped to from PLC where IO Device configuration was set In this examp...

Page 7: ...n diagram for Smart Slice Parameter configuration Ethernet to configure Smart Slices of IO Devices The PC running Cx Configurator FDT must have a unique IP address set on the same network as the Profi...

Page 8: ...on layout details It is not possible to connect with a blank Cx Configurator FDT network and upload devices that are connected to resurrect Cx Configurator FDT configuration Further Information For mo...

Reviews: