G3PX
G3PX
8
Operation
Error Detecting Function
Wiring
Single-phase Models
All G3PX-2
j
0EH/EHN/EC-series models incorporate terminals 11
and 12 for the CT Unit, 13 and 14 for the external reset switch, and
16 and 17 for relay output as well as power/input terminals 1 through
10.
Note:
1. Connect either the black or white lead wire of the CT
Unit to terminal 11 and the other lead wire to terminal
12. The G3PX will malfunction if you do not connect
the CT Unit to the G3PX.
2. The rated current and voltage of G3PX models when
reset are as follows:
EH-series models: 12 mA at 12 VDC
EHN- and EC-series models: 1 mA at 12 VDC
3. For more than one heater.
11
12
13
14
15
16
17
Load 1
Load 2
G3PX-2
j
0EH
Load
CT Unit
External reset
switch
CT Unit
G32X-CT
jj
Relay output
(SPDT)
(see note 1)
(see note 2)
(see note 3)
Load
Output
Single-phase Models
The following illustrations show the condition of the G3PX LED indi-
cators when the G3PX detects heater burnout, a short-mode failure
(ON failure of components), or overcurrent (EC-series con-
stant-current models only). The indicator and relay output signals
are reset with the internal or external reset switch provided that the
error condition has been remedied.
1. When EH/EHN/EC-series models detect single or multiple
heater burnout, the OPEN indicator is lit and the SPDT relay
output is ON.
Note:
When the G3PX detects heater burnout, the Level indicator
will be OFF regardless of the G3PX input condition. The red
OPEN indicator will be lit. EHN-series models, however,
will continue operating with level indication.
2. When EH/EHN/EC-series models detect a short-mode
failure, the SHORT indicator is lit and the SPDT relay output is
ON.
With continuous load current.
With load current shut off.
Note:
When the G3PX detects a short-mode failure, all LEDs of
the Level indicator and red SHORT indicator are lit. When
you use a breaker to disconnect the load with the relay out-
put, all LEDs of the Level indicator will be OFF regardless of
the input to the G3PX.
3. When EC-series models detect an overcurrent, the Level
indicator will flash and the SPDT relay output is ON. The input
signal will be shut off.
Note:
When resetting, leave power supply terminals 10 to 9 or 8
ON.