background image

Read and Understand This Catalog 

Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or 
comments. 
 

Warranty and Limitations of Liability 

 
WARRANTY 

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) 
from date of sale by OMRON. 
 
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR 
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS.    ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS 
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.    OMRON DISCLAIMS ALL OTHER 
WARRANTIES, EXPRESS OR IMPLIED. 

 

LIMITATIONS OF LIABILITY 

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS 
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT 
LIABILITY. 
 
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. 
 
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS 
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT 
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. 

 

 

Application Considerations 

 
SUITABILITY FOR USE 

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's 
application or use of the products.   
     
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the 
products.    This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, 
machine, system, or other application or use. 
 
The following are some examples of applications for which particular attention must be given.    This is not intended to be an exhaustive list of all possible 
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: 
 

  Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. 

 

  Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, 

safety equipment, and installations subject to separate industry or government regulations. 

 

  Systems, machines, and equipment that could present a risk to life or property.     

 
Please know and observe all prohibitions of use applicable to the products. 
 
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE 
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND 
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 

 

PROGRAMMABLE PRODUCTS 

OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. 

 

 

Disclaimers 

 
CHANGE IN SPECIFICATIONS 

Product specifications and accessories may be changed at any time based on improvements and other reasons. 
 
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.   
However, some specifications of the products may be changed without any notice.    When in doubt, special model numbers may be assigned to fix or 
establish key specifications for your application on your request.    Please consult with your OMRON representative at any time to confirm actual 
specifications of purchased products. 
 

DIMENSIONS AND WEIGHTS 

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. 

 

PERFORMANCE DATA 

Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the 
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON 
Warranty and Limitations of Liability. 

 

ERRORS AND OMISSIONS 

The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, 
typographical, or proofreading errors, or omissions. 

 

 
 

2010.1 

In the interest of product improvement, specifications are subject to change without notice. 

OMRON Corporation 

Industrial Automation Company 

 

http://www.ia.omron.com/ 

(c)Copyright OMRON Corporation 2010 All Right Reserved. 

Summary of Contents for G3PE-215B DC12-24

Page 1: ...Safety Precautions for All G3PE Models Number of phases Insulation method Operation indicator Rated input voltage Zero cross function Applicable load Model Single phase Phototriac coupler Yes yellow 1...

Page 2: ...5B G3PE 225B G3PE 235B G3PE 245B G3PE 215BL G3PE 225BL G3PE 235BL G3PE 245BL Item Operate time 1 2 of load power source cycle 1 ms max 1 ms max Release time 1 2 of load power source cycle 1 ms max Out...

Page 3: ...tage V Input current Input impedance Input current mA Input impedance k Ta 25 C 10 9 8 7 6 5 4 3 2 1 0 0 5 10 15 20 25 30 35 Input voltage V Input current Input impedance Input current mA Input impeda...

Page 4: ...10 20 11 0 25 Ambient temperature C Load current A 8 Relays 3 Relays 50 40 31 30 29 10 20 11 0 40 20 0 20 40 60 80 100 25 Ambient temperature C Load current A 8 Relays 3 Relays 5 7 20 15 13 12 10 5 0...

Page 5: ...t Diagram Output side t i u c r i c r e g g i r T Input side Input side Output side t i u c r i c r e g g i r T t i u c r i c t u p n I t i u c r i c t u p n I G3PE 235B L G3PE 245B L G3PE 535B L G3PE...

Page 6: ...products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems r...

Page 7: ...Operation indicator Rated input voltage Zero cross function Type Applicable load 1 Number of poles Model Three phase Phototriac coupler Yes yellow 12 to 24 VDC Yes DIN track mounting 2 15 A 100 to 24...

Page 8: ...Yes Externally attached heat sinks 15 A 100 to 240 VAC 3 G3PE 215B 3H DC12 24 2 G3PE 215B 2H DC12 24 25 A 100 to 240 VAC 3 G3PE 225B 3H DC12 24 2 G3PE 225B 2H DC12 24 35 A 100 to 240 VAC 3 G3PE 235B 3...

Page 9: ...3PE 525B 3 N G3PE 525B 2 N G3PE 535B 3 N G3PE 535B 2 N G3PE 545B 3 N G3PE 545B 2 N Item Rated load voltage 100 to 240 VAC 200 to 480 VAC Operating voltage range 75 to 264 VAC 180 to 528 VAC Rated load...

Page 10: ...100 C with no icing or condensation Ambient operating temperature 30 to 80 C with no icing or condensation Ambient operating humidity 45 to 85 Weight Approx 1 25 kg Approx 1 45 kg Approx 1 25 kg Appr...

Page 11: ...G3PE 525B 3 N G3PE 525B 2 N G3PE 215B 3 N G3PE 215B 2 N G3PE 515B 3 N G3PE 515B 2 N Load current A Ambient temperature C 50 45 40 35 30 20 14 10 0 30 20 0 20 40 60 80 100 18 12 G3PE 245B 3 N G3PE 245B...

Page 12: ...ms 500 400 300 200 100 0 10 30 50 100 300 500 1 000 3 000 5 000 Inrush current A Peak Energized time ms Heat Sink Area vs Load Current 40 C and 80 C G3PE 225B 3H G3PE 525B 3H Note The heat sink area...

Page 13: ...er Note With terminal cover Mounting Holes Models with DIN Track Mounting G3PE 215B 3N G3PE 215B 2N G3PE 225B 2N G3PE 515B 3N G3PE 515B 2N G3PE 525B 2N 120 max 84 5 max 110 100 64 80 max 68 68 32 2 20...

Page 14: ...or M4 Two R2 3 mounting holes Models with DIN Track Mounting G3PE 235B 3N G3PE 245B 2N G3PE 535B 3N G3PE 545B 2N Note Without terminal cover Note With terminal cover Mounting Holes 140 max 84 5 max 1...

Page 15: ...terminal cover Note With terminal cover A1 A2 A1 A2 G3PE 225B 2 G3PE 215B 3 L1 R T1 U T2 V T3 W L2 S L3 T L1 R T1 U T2 V T3 W L2 S L3 T L1 R T1 U T2 V T3 W L2 S L3 T A1 A2 G3PE 525B 2 L1 R T1 U T2 V...

Page 16: ...ls with Screw Mounting G3PE 225B 3 G3PE 235B 2 G3PE 525B 3 G3PE 535B 2 Note Without terminal cover Note With terminal cover A1 A2 A1 A2 G3PE 245B 2 G3PE 235B 3 L1 R T1 U T2 V T3 W L2 S L3 T L1 R T1 U...

Page 17: ...Four 8 dia Four 4 5 dia Two M3 5 Four 4 5 dia or M4 68 0 3 68 0 3 Mounting Holes Six M4 G3PE 15B H 25B H Six M5 G3PE 35B H 45B H 9 8 dia 4 5 dia 68 Models with Externally Attached Heat Sinks G3PE 215B...

Page 18: ...d G3PE 545B 3H 68 90 68 50 80 max 80 5 max 55 max 100 max 4 6 dia 4 6 5 6 elliptical hole 50 0 3 90 0 3 Two 4 5 dia or M4 Mounting Holes 68 110 5 max 60 68 Four M4 100 80 5 max 70 max Four R2 5 60 0 3...

Page 19: ...products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems r...