background image

3

G3PE-Three-phase

Specifications

Certification

UL508, CSA22.2 No.14, and EN60947-4-3

Ratings (at an Ambient Temperature of 25

°

C)

Operating Circuit (All Models)

Main Circuit of Models with Built-in Heat Sinks

*1.

The applicable load current depends on the ambient temperature. For details, refer to 

Load Current vs. Ambient Temperature

 in 

Engineering 

Data

 on page 5.

*2.

Applicable Load
Use the following formula to calculate the maximum total capacity of a heater load for a three-phase balanced load with delta connections. 
Maximum load capacity = Load current 

×

 Load voltage 

×

 

3

Example: 15 A 

×

 200 V 

×

 

3 = 5,196 W 

 5.1 kW

Example: 15 A 

×

 400 V 

×

 

3 = 10,392 W 

 10.3 kW

Main Circuit of Models with Externally Attached Heat Sinks

*

The rated load current depends on the heat sink or radiator that is mounted. It also depends on the ambient temperature.
For details, refer to 

Load Current vs. Ambient Temperature

 in 

Engineering Data

 on page 5.

ItemModel

Same for all models

Rated operating voltage

12 to 24 VDC

Operating voltage range

9.6 to 30 VDC

Rated input current (impedance) 10 mA max. (24 VDC)

Must-operate voltage

9.6 VDC max.

Must-release voltage

1 VDC min.

Insulation method

Phototriac

Operation indicator

Yellow LED

Model G3PE-

215B-

3(N)

G3PE-

215B-

2(N)

G3PE-

225B-

3(N)

G3PE-

225B-

2(N)

G3PE-

235B-

3(N)

G3PE-

235B-

2(N)

G3PE-

245B-

3(N)

G3PE-

245B-

2(N)

G3PE-

515B-

3(N)

G3PE-

515B-

2(N)

G3PE-

525B-

3(N)

G3PE-

525B-

2(N)

G3PE-

535B-

3(N)

G3PE-

535B-

2(N)

G3PE-

545B-

3(N)

G3PE-

545B-

2(N)

Item

Rated load voltage

100 to 240 VAC 

200 to 480 VAC

Operating voltage 
range

75 to 264 VAC

180 to 528 VAC

Rated load current 

*

1

15 A (at 40

°

C)

25 A (at 40

°

C)

35 A (at 25

°

C)

45 A (at 25

°

C)

15 A (at 40

°

C)

25 A (at 40

°

C)

35 A (at 25

°

C)

45 A (at 25

°

C)

Minimum load current

0.2 A

0.5 A

Inrush current 
resistance (peak 
value)

150 A

(60 Hz, 1 cycle)

220 A

(60 Hz, 1 cycle)

440 A

(60 Hz, 1 cycle)

220 A

(60 Hz, 1 cycle)

440 A

(60 Hz, 1 cycle)

Permissible I

2

(reference value)

121A

2

s

260A

2

s

1,260A

2

s

260A

2

s

1,260A

2

s

Applicable load 
(resistive load: AC1 
class) 

*

2

5.1 kW

(at 200 VAC)

8.6 kW

(at 200 VAC)

12.1 kW

(at 200 VAC)

15.5 kW

(at 200 VAC)

12.5 kW

(at 480 VAC)

20.7 kW

(at 480 VAC)

29.0 kW

(at 480 VAC)

37.4 kW

(at 480 VAC)

Model G3PE-

215B-

3H

G3PE-

215B-

2H

G3PE-

225B-

3HH

G3PE-

225B-

2H

G3PE-

235B-

3H

G3PE-

235B-

2H

G3PE-

245B-

3H

G3PE-

245B-

2H

G3PE-

515B-

3H

G3PE-

515B-

2H

G3PE-

525B-

3H

G3PE-

525B-

2H

G3PE-

535B-

3H

G3PE-

535B-

2H

G3PE-

545B-

3H

G3PE-

545B-

2H

Item

Rated load voltage

100 to 240 VAC

200 to 480 VAC

Operating voltage 
range

75 to 264 VAC

180 to 528 VAC

Rated load current 

*

15 A (at 40

°

C)

25 A (at 40

°

C)

35 A (at 25

°

C)

45 A (at 25

°

C)

15 A (at 40

°

C)

25 A (at 40

°

C)

35 A (at 25

°

C)

45 A (at 25

°

C)

Minimum load current

0.2 A

0.5 A

Inrush current 
resistance (peak 
value)

150 A

(60 Hz, 1 cycle)

220 A

(60 Hz, 1 cycle)

440 A

(60 Hz, 1 cycle)

220 A

(60 Hz, 1 cycle)

440 A

(60 Hz, 1 cycle)

Permissible I

2

(reference value)

121A

2

s

260A

2

s

1,260A

2

s

260A

2

s

1,260A

2

s

Applicable load 
(resistive load: AC1 
class)

Refer to 

Engineering Data

 on page 5.

Summary of Contents for G3PE-215B DC12-24

Page 1: ...Safety Precautions for All G3PE Models Number of phases Insulation method Operation indicator Rated input voltage Zero cross function Applicable load Model Single phase Phototriac coupler Yes yellow 1...

Page 2: ...5B G3PE 225B G3PE 235B G3PE 245B G3PE 215BL G3PE 225BL G3PE 235BL G3PE 245BL Item Operate time 1 2 of load power source cycle 1 ms max 1 ms max Release time 1 2 of load power source cycle 1 ms max Out...

Page 3: ...tage V Input current Input impedance Input current mA Input impedance k Ta 25 C 10 9 8 7 6 5 4 3 2 1 0 0 5 10 15 20 25 30 35 Input voltage V Input current Input impedance Input current mA Input impeda...

Page 4: ...10 20 11 0 25 Ambient temperature C Load current A 8 Relays 3 Relays 50 40 31 30 29 10 20 11 0 40 20 0 20 40 60 80 100 25 Ambient temperature C Load current A 8 Relays 3 Relays 5 7 20 15 13 12 10 5 0...

Page 5: ...t Diagram Output side t i u c r i c r e g g i r T Input side Input side Output side t i u c r i c r e g g i r T t i u c r i c t u p n I t i u c r i c t u p n I G3PE 235B L G3PE 245B L G3PE 535B L G3PE...

Page 6: ...products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems r...

Page 7: ...Operation indicator Rated input voltage Zero cross function Type Applicable load 1 Number of poles Model Three phase Phototriac coupler Yes yellow 12 to 24 VDC Yes DIN track mounting 2 15 A 100 to 24...

Page 8: ...Yes Externally attached heat sinks 15 A 100 to 240 VAC 3 G3PE 215B 3H DC12 24 2 G3PE 215B 2H DC12 24 25 A 100 to 240 VAC 3 G3PE 225B 3H DC12 24 2 G3PE 225B 2H DC12 24 35 A 100 to 240 VAC 3 G3PE 235B 3...

Page 9: ...3PE 525B 3 N G3PE 525B 2 N G3PE 535B 3 N G3PE 535B 2 N G3PE 545B 3 N G3PE 545B 2 N Item Rated load voltage 100 to 240 VAC 200 to 480 VAC Operating voltage range 75 to 264 VAC 180 to 528 VAC Rated load...

Page 10: ...100 C with no icing or condensation Ambient operating temperature 30 to 80 C with no icing or condensation Ambient operating humidity 45 to 85 Weight Approx 1 25 kg Approx 1 45 kg Approx 1 25 kg Appr...

Page 11: ...G3PE 525B 3 N G3PE 525B 2 N G3PE 215B 3 N G3PE 215B 2 N G3PE 515B 3 N G3PE 515B 2 N Load current A Ambient temperature C 50 45 40 35 30 20 14 10 0 30 20 0 20 40 60 80 100 18 12 G3PE 245B 3 N G3PE 245B...

Page 12: ...ms 500 400 300 200 100 0 10 30 50 100 300 500 1 000 3 000 5 000 Inrush current A Peak Energized time ms Heat Sink Area vs Load Current 40 C and 80 C G3PE 225B 3H G3PE 525B 3H Note The heat sink area...

Page 13: ...er Note With terminal cover Mounting Holes Models with DIN Track Mounting G3PE 215B 3N G3PE 215B 2N G3PE 225B 2N G3PE 515B 3N G3PE 515B 2N G3PE 525B 2N 120 max 84 5 max 110 100 64 80 max 68 68 32 2 20...

Page 14: ...or M4 Two R2 3 mounting holes Models with DIN Track Mounting G3PE 235B 3N G3PE 245B 2N G3PE 535B 3N G3PE 545B 2N Note Without terminal cover Note With terminal cover Mounting Holes 140 max 84 5 max 1...

Page 15: ...terminal cover Note With terminal cover A1 A2 A1 A2 G3PE 225B 2 G3PE 215B 3 L1 R T1 U T2 V T3 W L2 S L3 T L1 R T1 U T2 V T3 W L2 S L3 T L1 R T1 U T2 V T3 W L2 S L3 T A1 A2 G3PE 525B 2 L1 R T1 U T2 V...

Page 16: ...ls with Screw Mounting G3PE 225B 3 G3PE 235B 2 G3PE 525B 3 G3PE 535B 2 Note Without terminal cover Note With terminal cover A1 A2 A1 A2 G3PE 245B 2 G3PE 235B 3 L1 R T1 U T2 V T3 W L2 S L3 T L1 R T1 U...

Page 17: ...Four 8 dia Four 4 5 dia Two M3 5 Four 4 5 dia or M4 68 0 3 68 0 3 Mounting Holes Six M4 G3PE 15B H 25B H Six M5 G3PE 35B H 45B H 9 8 dia 4 5 dia 68 Models with Externally Attached Heat Sinks G3PE 215B...

Page 18: ...d G3PE 545B 3H 68 90 68 50 80 max 80 5 max 55 max 100 max 4 6 dia 4 6 5 6 elliptical hole 50 0 3 90 0 3 Two 4 5 dia or M4 Mounting Holes 68 110 5 max 60 68 Four M4 100 80 5 max 70 max Four R2 5 60 0 3...

Page 19: ...products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems r...

Reviews: