background image

FZ5-L35

FZ5-L35

-10

USB memory

FZ-MEM2G

FZ-MEM8G

Recommended Model

By OMRON Corporation

 S8VS-12024

FZ5-L35

□)

 S8VS-18024

FZ5-L35

-10

*

Camera 2ch type

FZ5-L350
FZ5-L355

Camera 4ch type

FZ5-L350-10
FZ5-L355-10

Sensor Controller

© OMRON Corporation  2013  All Rights Reserved. 

Model

INSTRUCTION SHEET

Thank you for selecting OMRON product. This sheet 

primarily describes precautions required in installing and 

operating the product.

Before operating the product, read the sheet thoroughly 

to acquire sufficient knowledge of the product. For your 

convenience, keep the sheet at your disposal.

The following notice applies only to products that carry the CE mark:

Notice:

This is a class A product. In residential areas it may cause radio 

interference, in which case the user may be required to take adequate 

measures to reduce interference.

Manufacturer:

  Omron Corporation,

  Shiokoji Horikawa, Shimogyo-ku,

  Kyoto 600-8530 JAPAN

  Ayabe Factory

  3-2 Narutani, Nakayama-cho,

  Ayabe-shi, Kyoto 623-0105 JAPAN

TRACEABILITY INFORMATION:

Representative in EU:

  Omron Europe B.V.

  Wegalaan 67-69

  2132 JD Hoofddorp,

  The Netherlands

Meanings of Signal Words

Meanings of Alert Symbols

Alert statements in this Manual

The following alert symbols are used in this manual.

The following alert statements apply to the products in this 

manual. Each alert statement also appears at the locations 

needed in this manual to attract your attention.

Indicates a potentially hazardous 

situation which, if not avoided, will 

result in minor or moderate injury, or 

may result in serious injury or death. 

Additionally there may be significant 

property damage.

WARNING

Indicates a potentially hazardous 

situation which, if not avoided, may 

result in minor or moderate injury or in 

property damage.

Indicates general prohibitions for which there is 

no specific symbol.
Indicates the possibility of electric shock under 

specific conditions.
Indicates the possibility of explosion under 

specific conditions.

Indicates the possibility of laser radiation.

Indicates the possibility of injury by high 

temperature under specific conditions.

CAUTION

Symbols and the meanings for safety precautions 

described in this manual.

In order for the product to be used safely, the following 

indications are used in this book to draw your attention to 

the cautions. The cautions with the indications describe 

the important contents for safety.

WARNING

CAUTION

This product must be used according to the 

instruction manual. Failure to observe this may 

result in impairment of functions and 

performance of the product.
This product is not designed or rated for 

ensuring safety of persons. Do not use it for 

such purposes.
Never connect the AC power supply with this

product. When the AC power supply is

connected, it causes the electric shock and a fire.
A lithium battery is built into the Controller and 

may occasionally combust, explode, or burn if 

not treated properly. Dispose of the Controller as 

industrial waste, and never disassemble, apply 

pressure that would deform, heat to 100

 or 

higher, or incinerate the Controller.
Since camera that can be connected with this 

product emits a visible light that may have an 

adverse effect on the eyes, do not stare directly 

into the light emitted from the LED. If a specular 

object is used, take care not to allow reflected 

light enter your eyes.

Danger of burns. Do not touch the case while the 

LED is ON or just after power is turned OFF, 

since it remains extremely hot.

8.5mm max.

8.5mm max.

Precautions for Safe Use

Installation Environment

• Do not use the product in areas where flammable or explosive 

gases are present.

• Install the product so that air can flow freely through its cooling 

vents.

Clean the vent regularly so as not to be clogged by dust. Clogging 

of the vent may result in overheat and failure.

• Do not install the product close to high-voltage devices and power 

devices in order to secure the safety of operation and 

maintenance.

• Make sure to tighten all installation screws securely.

Power Supply and Wiring

• Make sure to use the product with the power supply voltage 

specified by this manual.

• Use a power supply cable and crimp terminals of the specified size. 

Do not simply connect the twisted ends of the wires directly to the 

terminal block.

-Applicable wire size:1.31 to 2.63mm

2

-Terminal screw:M4

-Crimp terminals

• Keep the power supply wires as short as possible

(Max.10m).

• Use a DC power supply with safety measures against high-voltage 

spikes(safety extra low-voltage circuits on the secondary side).

• Do the following confirmations again before turning on the power 

supply. 

 - Is the voltage of the power supply correct? (24VDC)

 - Is not the load of the output signal short-circuited?

 - Is the load current of the output signal appropriate?

 - Is not the mistake found in wiring?

●Ground

• 

The controller power circuit is not insulated from its internal 

circuit.

• 

Be sure to use a spacer when connecting a camera to the 

controller. As the housing of the camera is the SG (0V), it can 
cause short-circuiting between the SG (0V) and the FG if a 
spacer is not used.

• It is short-circuited with FG of the customer device when 

installing it directly because the case of the controller is 

connected with SG(0V).

• Do not ground the 24VDC power supply's positive terminal. If the 

positive terminal is grounded, it causes the electric shock when 

you touch the SG(0V) such as case of the controller or the 

camera.

Other

• Use only the camera and cables designed specifically for the 

product. Failure to observe this result in malfunction or damage of 

the product.

• Always turn off the power of the sensor controller before 

plugging/unplugging a camera and/or cable. Plugging a cable while 

the power is on may result in a failure of a camera and/or 

peripherals.

• Do not attempt to dismantle,repair,or modify the product.

• Should you notice any abnormalities,immediately stop use,turn OFF 

the power supply,and contact your OMRON representative.

• Do not touch fluorescent or halogen lights while the power is ON or 

immediately after the power is turned OFF.

• Dispose of this product as industrial waste.

Do not drop the product and/or apply abnormal oscillation and/or 

impact.It may result in a failure and/or burnout.

Be careful not to drop while handling.

A built-in lithium battery may occasionally cause severe damage 

sue to fire and/or explosion.

For the cable that is flexed repeatedly, use the robotic cable type 

(flexing resistance type) to prevent damages.

Do not apply torsion stress to the cable. It may damage the cable.

Secure the minimum bending radius of the cable. Otherwise the 

cable may be damaged.

Regulations and Standards

The Controller complies with the following standards.

EC Directive 2004/108/EC

EN standard EN61326-1

CSA Standard CSA C22.2 No.61010-1

Regulation of KC marking

A급 기기(업무용 방송통신기자재)

이 기기는 업무용(A급) 전자파적합기기로서 판매자

또는 사용자는 이 점을 주의하시기 바라며,가정외의

지역에서 사용하는 것을 목적으로 합니다.

Precautions for Correct Use

Installation and Storage Sites

Install and store the product in a location that meets the 

following conditions:

• Surrounding temperature of 0 to 50℃ (-20 to +65℃ in 

storage)

• No rapid changes in temperature (place where dew does not 

form)

• Relative humidity of between 35 to 85 %

• No presence of corrosive or flammable gases

• Place free of dust, salts and iron particles

• Place free of vibration and shock

• Place out of direct sunlight

• Place where it will not come into contact with water, oils or 

chemicals

Orientation of Product

To improve heat dissipation, install the product in the

following orientation only.

Ambient Temperature

• Maintain a minimum clearance of 50 mm above the controller 

to improve air circulation. A minimum clearance of 25 mm 

between other devices must also be maintained on the right, 

left and back sidesof product.

• Do not install the product immediately above significant heat 

sources, such as heaters, transformers, or large-capacity 

resistors.

• Do not let the ambient temperature exceed 50

(122°F).

• Provide a forced-air fan cooling or air conditioning if the 

ambient temperature is near 50

(122°F) so that the

ambient temperature never exceeds 50

(122°F).

Noise Resistance

• Do not install the product in a cabinet containing high-voltage 

equipment.

• Do not install the product within 200 mm of power cables.

Component Installation and Handling

• Touching Signal Lines

To prevent damage from static electricity, use a wrist strap or 

another device for preventing electrostatic discharges when 

touching terminals or signal lines in connectors.

• Handling a USB Memory

To remove a USB memory, make sure that data is not being 

read or written to it. The LED on the USB memory flashes 

while data is being read or written, so make sure that it is lit 

steadily before removing the memory.

• Turning OFF the Power

Do not turn OFF the power while a message is being 

displayed indicating that processing is being performed. Data 

in memory will be corrupted, and the product may not operate 

correctly the next time it is started.

• Using the RESET Signal

Do not use the RESET input immediately after power is turned 

ON. When using the RESET input to synchronize startup 

timing,wait at least 15 second after the Controller’ s power 

supply is turned ON before turning ON the RESET signal.

Maintenance

Turn OFF the power and take safety precautions before 

conducting inspections. Electrical shock can result from 

attempting safety inspections with the power turned ON.

• Clean the lens with a lens-cleaning cloth or air brush.

• Lightly wipe off dirt with a soft cloth.

• Dirt on the CCD must be removed using an air brush.

• Do not use thinners or benzene.

Communication with High-order Device

After confirming that this product is started up, communicate 

with the high-order device. When this product has started up, 

an indefinite signal may be output from the high-order 

interface. To avoid this problem, clear the receiving buffer of 

your device at initial operations.

Do not install in this orientation.

Basic Configuration

* Items indicated with an asterisk are dedicated items, and cannot be substituted.

The Controller performs the image 

processing specified by the user settings 

and outputs the measurement results.

*

*

Camera cable

FZ-VS (2m, 5m,10m, min. bending radius: 69mm)
Bend resistant camera cable

FZ-VSB (2m, 5m, 10m min. bending radius: 69mm)
Right-angle camera cable

FZ-VSL (2m,5m,10m min. bending radius: 69mm)
Long-distance camera cable

FZ-VS2 (15m min. bending radius: 93mm)
Long-distance Right-angle camera cable

FZ-VSL2 (15m min. bending radius: 93mm)

Camera cable

Standalone camera

FZ-SC/FZ-S/

FZ-SC2M/FZ-S2M/

FZ-SC5M2/FZ-S5M2/

FZ-SFC/FZ-SF/

FZ-SPC/FZ-SP/

FZ-SHC/FZ-SH
Intelligent compact camera

FZ-SQ010F/FZ-SQ050F/

FZ-SQ100F/FZ-SQ100N
Intelligent camera

FZ-SLC15/FZ-SLC100
Automatic focus camera

FZ-SZC15/FZ-SZC100

Detects workpieces as images.

Camera

*

LCD monitor

Monitor cable

*

*

Use the monitor to check images and

display the condition-setting menus.

FZ-M08 (8.4-inch)

FZ-VM (2m, 5m, min. bending radius: 75mm)

Power Supply

Peripheral Device

Input Device

Mouse, track ball

(Commercially available USB devices)

This product contains a lithium battery for which the following notice applies :Perchlorate Material - special 

handling may apply.

See www.dtsc.ca.gov/hazardouswaste/perchlorate

Power Supply Wiring

24VDC

FZ5-L35

/FZ5-L35

-10

 Lit while power is ON.

 Lit while the controller is in Run Mode.

 Lit when an error has occurred.

 Connect the controller to external devices such as a sync sensor and PLC.

 Connect cameras.

 Connect a DC power supply. Wire the power supply unit independently of other devices. After wiring, 

replace the terminal cover.

• The following items can be connected to USB ports.  • Commercially available track ball, mause and USB memory.
• Never insert/remove USB devices during measurement. It may affect measurement time and/or destroy data.

 Connect a monitor.

 Connect an external device such as a personal computer or PLC.

 Connect an external device such as a personal computer or PLC.

⑩ 

Connect a mouse and USB memory, etc. Two USB ports are provided and any of them can be used. 
However, when USB memory is connected with both ports, doing so may cause the USB memories to 
come into contact, resulting in malfunction or damage.

POWER LED

USB connector

Monitor connector (analog RGB)

Ethernet connector

Camera connector

Only Camera 4ch type

(FZ5 -L35

-10)

RS-232C connector

Power terminal

I/O connector

(control lines, data lines)

RUN LED

ERROR LED

Component Names and Functions

U.S. California Notice:

Image Processing System

Summary of Contents for fz5-l35 series

Page 1: ...不定な信号 が出る可能性がありますので 初期動作時はご使用機器の受信 バッファをクリアするなどの処置を実施してください この製品はカリフォルニア州法で規制されている過塩素酸塩を含むリチウムバッテリを内蔵しておりますので この州法へ の対応をしてください 詳しくは 下記URLをご覧ください www dtsc ca gov hazardouswaste perchlorate 米国カリフォルニア州過塩素酸塩規制について 基本構成 各部の名称とはたらき 印は専用品です これら以外は使用できません USBメモリ 形FZ MEM2G 形FZ MEM8G マウス トラックボール USBインタフェースの市販品 推奨品 オムロン 株 製 形S8VS 12024 FZ5 L35 形S8VS 18024 FZ5 L35 10 単体カメラ 形FZ SC 形FZ S 形FZ SC2M 形FZ S2M 形FZ SC...

Page 2: ...7 8 9 信号名 NC SD RD NC NC NC NC NC GND 役割 無接続 送信データ用 受信データ用 無接続 無接続 無接続 無接続 無接続 信号用接地 ピン番号 1 2 3 4 5 6 7 8 信号名 TD TD RD NC NC RD NC NC 信号方向 出力 出力 入力 入力 信号名 TRD 0 TRD 0 TRD 1 TRD 2 TRD 2 TRD 1 TRD 3 TRD 3 信号方向 入出力 入出力 入出力 入出力 入出力 入出力 入出力 入出力 プラグ フード メーカ オムロン 株 オムロン 株 形式 形XM3A 0921 形XM2S 0911 信号名 SD RD GND コントローラ RS 232C ピン番号 2 3 9 ピン番号 接続する外部装置 RS CS制御はできません ケーブル長は 15m以下にしてください 信号名 SD RD GND 操作 シリアル...

Page 3: ...r apply abnormal oscillation and or impact It may result in a failure and or burnout Be careful not to drop while handling A built in lithium battery may occasionally cause severe damage sue to fire and or explosion For the cable that is flexed repeatedly use the robotic cable type flexing resistance type to prevent damages Do not apply torsion stress to the cable It may damage the cable Secure th...

Page 4: ...nal name TRD 0 TRD 0 TRD 1 TRD 2 TRD 2 TRD 1 TRD 3 TRD 3 Signal direction In Out In Out In Out In Out In Out In Out In Out In Out 100BASE TX 10BASE T 1000BASE T Dimensions Mounting Fix without removing the insulation leg because neither the ventilation route is closed nor the case are connected with FG 51 4 M4 DEPTH6 5 INSULATION LEG 100 59 10 5 Operation Serial communications Network communicatio...

Reviews: