background image

182.3

FZ5-L350
FZ5-L355

FZ5-L350-10
FZ5-L355-10

80

197

12

I/O Connector

Connector

NPN I/O type
PNP I/O type

Connect the parallel I/O cable (FZ-VP or FZ-VPX (optional)) ensuring minimum bend radius or larger.

FZ5-L350/FZ5-L350-10
FZ5-L355/FZ5-L355-10

*In camera 2ch type, only STGOUT0 and STGOUT1 can be used.
NOTE1. The wire color and the mark correspond to FZ-VP. 

NOTE2. No. corresponds to the terminal number of FZ-VPX. 

Item
Input
specification

Output
specification

NPN I/O type
ON

:

Shorted to 0V, or 1.5V max.

OFF

:

Open (leakage current: 0.1mA max.)

NPN open collector
24 VDC, 50 mA max. residual voltage:1.2V max.

PNP I/O type
ON

:

Shorted to power supply voltage, 

or power supply voltage -1.5V min.

OFF

:

Open (leakage current: 0.1mA max.)

PNP open collector
24 VDC, 50 mA max. residual voltage: 1.2V max.

No.

A1

A2

A3

A4

A5

A6

A7

A8

A9

A10

A11

A12

A13

A14

A15

A16

A17

A18

A19

A20

A21

A22

A23

A24

A25

Signal name

(Open)

(Open)

(Open)

(Open)

(Open)

DI1

DI3

DI5

DI7

STGOUT1

STGOUT3

ERROR

(Open)

(Open)

(Open)

(Open)

(Open)

DO1

DO3

DO5

DO7

DO9

DO11

DO13

(Open)

Wire color

Orange

Gray

White

Yellow

Pink

Orange

Gray

White

Yellow

Pink

Orange

Gray

White

Yellow

Pink

Orange

Gray

White

Yellow

Pink

Orange

Gray

White

Yellow

Pink

Wire color

Orange

Gray

White

Yellow

Pink

Orange

Gray

White

Yellow

Pink

Orange

Gray

White

Yellow

Pink

Orange

Gray

White

Yellow

Pink

Orange

Gray

White

Yellow

Pink

Mark (red)






■ ■
■ ■
■ ■
■ ■
■ ■
■ ■ ■
■ ■ ■
■ ■ ■
■ ■ ■
■ ■ ■
■ ■ ■ ■
■ ■ ■ ■
■ ■ ■ ■
■ ■ ■ ■
■ ■ ■ ■
■■■■
■■■■
■■■■
■■■■
■■■■

Mark (blk)






■ ■
■ ■
■ ■
■ ■
■ ■
■ ■ ■
■ ■ ■
■ ■ ■
■ ■ ■
■ ■ ■
■ ■ ■ ■
■ ■ ■ ■
■ ■ ■ ■
■ ■ ■ ■
■ ■ ■ ■
■■■■
■■■■
■■■■
■■■■
■■■■

Function

Command inputs

Strobe trigger output (*)

Strobe trigger output (*)

ON when there is an error.

Data output

No.

B1

B2

B3

B4

B5

B6

B7

B8

B9

B10

B11

B12

B13

B14

B15

B16

B17

B18

B19

B20

B21

B22

B23

B24

B25

Signal name

RESET

(Open)

(Open)

STEP0

DSA0

DI0

DI2

DI4

DI6

STGOUT0

STGOUT2

RUN

BUSY0

GATE0

OR0

READY0

DO0

DO2

DO4

DO6

DO8

DO10

DO12

DO14

DO15

Function

Controller restart

Measurement trigger input

Data send request signal

Command inputs

Strobe trigger output (*)

Strobe trigger output (*)

ON while in Run mode

ON during processing

ON for the set output time

Overall judgment result

ON when image input is allowed

Data output

• FZ-VP (2m, 5m, min. bending radius: 75mm)

• FZ-VPX (2m, 5m, min. bending radius: 75mm)

NPN I/O type:FZ5-L350/FZ5-L350-10

PNP I/O type:FZ5-L355/FZ5-L355-10

Controller

Parallel

connector

Parallel

connector

Power

terminal

Power

terminal

Controller

+24V

0V

Parallel Interface

Each output signal

Each output signal

Each input signal

Each input signal

+24V

0V

24 VDC

24 VDC

Load

Load

Connector

Wiring

Connection Method

Pin numbers will depend on the external device being connected. Refer to the manual for the personal 

computer or PLC being connected.

1

2

3

4

5

6

7

8

9

Use a shielded cable.

Use a compatible connector.

• Recommended items

Pin No.

1

2

3

4

5

6

7

8

9

Signal name

NC

SD

RD

NC

NC

NC

NC

NC

GND

Function

Not connected

For RS-232C

For RS-232C

Not connected

Not connected

Not connected

Not connected

Not connected

Signal ground

Plug

Hood

Manufacturer

OMRON Corporation

OMRON Corporation

Model

XM3A-0921

XM2S-0911

Controller

• RS-232C

Pin No.

2
3
9

Pin No.

*
*
*

External device to be connected

RS/CS control cannot be used.

The maximum cable length is 15m.

Signal name

SD
RD

GND

Signal name

SD
RD

GND

Align the connector with the socket and press it 

straight into place, then fix it with the screws on 

both sides of the connector.

Connect the cable ensuring the minimum bend 

radius or larger.

Turn OFF the power supply before connecting or 

disconnecting a Parallel I/O Cable. Peripheral 

devices may be damaged if the cable is connected 

or disconnected with the power ON.

Serial Interface

Ethernet interface

Connector

RJ45 8-pin modular connector

Use LAN cable of category 5e or more when connecting it with 1000BASE-T.

Pin No.

1

2

3

4

5

6

7

8

Signal name

TD

TD

RD

NC

NC

RD

NC

NC

Signal direction

Out

Out

In


In


Signal name

TRD

(0)

TRD

(0)

TRD

(1)

TRD

(2)

TRD

(2)

TRD

(1)

TRD

(3)

TRD

(3)

Signal direction

In/Out

In/Out

In/Out

In/Out

In/Out

In/Out

In/Out

In/Out

100BASE-TX/10BASE-T

1000BASE-T

Dimensions

Mounting

*Fix without removing the insulation leg because neither 

the ventilation route is closed nor the case are connected 

with FG.

51

4-M4 DEPTH6.5

INSULATION LEG

100

59

10.5

Operation
Serial communications
Network communications
EtherNetI/P communications

Parallel I/O

Monitor interface
USB interface
Power supply voltage
Current consumption
(At Power supply voltage 24VDC)

Noise resistance

Vibration resistance

Shock resistance
Ambient temperature range

Ambient humidity range
Ambient environment
Degree of protection
Environmental conditions
(according to IEC61010-1)

Case materials
Weight
Content goods

Mouse or similar device
RS-232C
Ethernet 1000BASE-T/100BASE-TX/10BASE-T
Used Ethernet port
Transmission speed:100Mbps(100BASE-TX)
11 inputs (RESET, STEP0,DSA0,DI0 to 7)
26 outputs (RUN,BUSY0,GATE0,OR0,READY0,ERROR,STGOUT0 to 3, DO0 to 15)
Analog RGB video output 1 channel (Resolusion: XGA 1024×768)
2 channels (supports USB1.1 and 2.0)
24 V DC (20.4 to 26.4 V DC)
Consumption of current varies depending on the type of camera connected.
When FZ-S

/FZ-S

2M/FZ-S

5M

/FZ-SF

/FZ-SP

/FZ-SH

 is connected:

Camera 2ch type:Approx. 2.6A max. Camera 4ch type:Approx. 2.9A max.

When FZ-SLC

□□□

/FZ-SZC

□□□

 is connected:

Camera 2ch type:Approx. 4.0A max. Camera 4ch type:Approx. 5.5A max.

When FZ-SQ

□□□□

 is connected:

Camera 2ch type:Approx. 4.0A max. Camera 4ch type:Approx. 5.5A max.

1 kV, pulse rise: 5 ns Pulse width: 50 ns
Burst continuing time: 15 ms Cycle: 300 ms
10 to 150 Hz, one-side amplitude 0.1 mm (Max. acceleration 15m/s

2

)

10 times for 8 minutes for each three direction
150 m/s

2

; 3 times each in 6 directions

Operating: 0 to 50 °C (with no icing nor no condensation)
Storage: –20 to +65 °C (with no icing nor no condensation)
Operating and storage: 35 % to 85 % (no condensation)
No corrosive gases
IEC60529 IP20
Indoor use
Maximum altitude of 2,000m
Supply voltage fluctuations of +10 %, –15 % of the rated voltage
Installation category I
Pollution degree 2
Plating steel board
Approx. 1.8 kg
Controller 

 

 

 Qty:1

Instruction Manual 

 

 

 Qty:1 piece for each Japanese and English

Controller Specifications

OMRON Corporation

Suitability for Use

EUROPE

OMRON EUROPE B.V. Sensor Business Unit

Carl-Benz Str.4, D-71154 Nufringen Germany

Phone:49-7032-811-0  Fax: 49-7032-811-199

NORTH AMERICA

OMRON ELECTRONICS  LLC

One Commerce Drive Schaumburg,IL 60173-5302 U.S.A.

Phone:1-847-843-7900  Fax : 1-847-843-7787

ASIA-PACIFIC

OMRON ASIA PACIFIC PTE. LTD.

No. 438A Alexandra Road #05-05-08(Lobby 2),

Alexandra Technopark, Singapore 119967 

Phone : 65-6835-3011  Fax :65-6835-2711

THE PRODUCTS CONTAINED IN THIS SHEET ARE NOT SAFETY RATED.  

THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF 

PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY 

COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES.

Please refer to separate catalogs for OMRON's safety rated products.

OMRON shall not be responsible for conformity with any standards, codes, 

or regulations that apply to the combination of the products in the 

customer's application or use of the product. 

 

Take all necessary steps to determine the suitability of the product for the 

systems, machines, and equipment with which it will be used.

Know and observe all prohibitions of use applicable to this product.

 

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS 

RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS 

A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT 

THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE 

INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

See also Product catalog for Warranty and Limitation of Liability.

CHINA

OMRON(CHINA) CO., LTD. 

Room 2211, Bank of China Tower,

200 Yin Cheng Zhong Road, 

PuDong New Area, Shanghai, 200120, China

Phone : 86-21-5037-2222  Fax :86-21-5037-2200

OCT. 2009

D

Summary of Contents for fz5-l35 series

Page 1: ...不定な信号 が出る可能性がありますので 初期動作時はご使用機器の受信 バッファをクリアするなどの処置を実施してください この製品はカリフォルニア州法で規制されている過塩素酸塩を含むリチウムバッテリを内蔵しておりますので この州法へ の対応をしてください 詳しくは 下記URLをご覧ください www dtsc ca gov hazardouswaste perchlorate 米国カリフォルニア州過塩素酸塩規制について 基本構成 各部の名称とはたらき 印は専用品です これら以外は使用できません USBメモリ 形FZ MEM2G 形FZ MEM8G マウス トラックボール USBインタフェースの市販品 推奨品 オムロン 株 製 形S8VS 12024 FZ5 L35 形S8VS 18024 FZ5 L35 10 単体カメラ 形FZ SC 形FZ S 形FZ SC2M 形FZ S2M 形FZ SC...

Page 2: ...7 8 9 信号名 NC SD RD NC NC NC NC NC GND 役割 無接続 送信データ用 受信データ用 無接続 無接続 無接続 無接続 無接続 信号用接地 ピン番号 1 2 3 4 5 6 7 8 信号名 TD TD RD NC NC RD NC NC 信号方向 出力 出力 入力 入力 信号名 TRD 0 TRD 0 TRD 1 TRD 2 TRD 2 TRD 1 TRD 3 TRD 3 信号方向 入出力 入出力 入出力 入出力 入出力 入出力 入出力 入出力 プラグ フード メーカ オムロン 株 オムロン 株 形式 形XM3A 0921 形XM2S 0911 信号名 SD RD GND コントローラ RS 232C ピン番号 2 3 9 ピン番号 接続する外部装置 RS CS制御はできません ケーブル長は 15m以下にしてください 信号名 SD RD GND 操作 シリアル...

Page 3: ...r apply abnormal oscillation and or impact It may result in a failure and or burnout Be careful not to drop while handling A built in lithium battery may occasionally cause severe damage sue to fire and or explosion For the cable that is flexed repeatedly use the robotic cable type flexing resistance type to prevent damages Do not apply torsion stress to the cable It may damage the cable Secure th...

Page 4: ...nal name TRD 0 TRD 0 TRD 1 TRD 2 TRD 2 TRD 1 TRD 3 TRD 3 Signal direction In Out In Out In Out In Out In Out In Out In Out In Out 100BASE TX 10BASE T 1000BASE T Dimensions Mounting Fix without removing the insulation leg because neither the ventilation route is closed nor the case are connected with FG 51 4 M4 DEPTH6 5 INSULATION LEG 100 59 10 5 Operation Serial communications Network communicatio...