Using Custom Command
273
Description
The number of the <sceneDescription> is less than 255 characters.
The scene that is bigger than maximum scene number cannot set explanation.
Example
Gets the explanation of scene. Set a explanation if unestablished.
'Gets the explanation of scene
description$ = SceneDescription$(1)
If description$ = "" Then
'Set the explanation.
SetSceneDescription 1, "Description 1"
Endif
Set the scene group title name
SetSceneGroupTitle <sceneGroupNo> , <sceneGroupTitle>
Parameters
<sceneGroupNo>
Scene group number (integer type)
<sceneGroupTitle>
title name (character type)
Return Value
None.
Description
Do not appoint it other than -1 in an <sceneGroupNo>.
The number of the <sceneGroupTitle> is less than 15 characters.
Example
Gets the title name of scene group 0. Set a title name if unestablished.
If SceneGroupTitle$(-1) = "" Then
SetSceneGroupTitle -1 , "Group name"
Endif
Set the scene maker name
SetSceneMaker <sceneNo>, <sceneMaker>
Parameters
<sceneNo>
Scene number (integer type)
<sceneMaker>
maker name (character type)