7
External
Reference
Tables
FZ3 User's Manual
Support measurement
241
2
Size of figures
Get only
Size of figures acquired
120
Target processing
unit No.
Set/Get
0 to 9999
121
Target figure No.
Set/Get
0 to 999
1000 + 100 x N
(N = 0 to 9)
Figure N type
(N = 0 to 9)
Get only
Figure 0 type
0x0000
→
Undefined
0x0001
→
Point
0x0002
→
Line
0x0004
→
Wide line
0x0008
→
Rectangle
0x0010
→
Ellipse
0x0020
→
Circle
0x0040
→
Wide circle
0x0080
→
Arc
0x0100
→
Wide arc
0x0200
→
Polygon
Set to 0 if no figures are acquired.
1001 + 100 x N
(N = 0 to 9)
Figure N drawing
mode
(N = 0 to 9)
Get only
Figure N drawing mode
1002 + 100 x N
to
1022 + 100 x N
(N = 0 to 9)
Figure N data 00
to Figure N data
20
(N = 0 to 9)
Get only
Figure N data 0 to 20
The amount of valid data differs with data type.
Set to 0 if disabled or no figures are acquired.
Trend Monitor
No.
Data name
Set/Get
Data range
0
Judge
Get only
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
5
Measurement
Get only
-999999999.9999 to 999999999.9999
6
Warning
Get only
0: OFF
1: ON
7
Maximum
Get only
-999999999.9999 to 999999999.9999
8
Minimum
Get only
-999999999.9999 to 999999999.9999
9
Average
Get only
-999999999.9999 to 999999999.9999
10
Deviation
Get only
-999999999.9999 to 999999999.9999
11
Count
Get only
0 to 999999999
12
NG count
Get only
0 to 999999999
13
Warning count
Get only
0 to 999999999
103
Reflect to overall
judgement
Set/Get
0: ON, 1: OFF
121
Upper limit of the
judgement
Set/Get
-999999999.9999 to 999999999.9999
122
Lower limit of the
judgement
Set/Get
-999999999.9999 to 999999999.9999
123
Warning upper limit
Set/Get
-999999999.9999 to 999999999.9999
124
Warning lower limit
Set/Get
-999999999.9999 to 999999999.9999