No.20S046-00
41/62
FS-C4KU7DGES-F / FS-C4KU7DGES-M42 / FS-C2KU7DGES-F / FS-C2KU7DGES-M42 / FS-C2KU7DGES-C
Product Specifications and Use’s Guide
10.12 Counter And Timer Control
Controls “Timer” and “Counter”.
Timer Control
GenICam Parameters
TimerSelector
IEnumeration
Type
Setup timer selection
Selection: Timer0, Timer1
Default: Timer0
TimerDuration
IFloat Type
Duration of “Timer active” signal (in µsecond)
Range: 1 to
4,294,967,295
Default: 1
TimerDelay
IFloat Type
Delay for “Timer active” signal (in µsecond)
Range: 0 to
4,294,967,295
Default: 0
TimerValue
IFloat Type
Returns value for “Timer active” signal
TimerTriggerSource
IEnumeration
Type
Reference signal selection to generate “Timer active” signal
Selection: Off, Line0, Line1, Line2, FrameTrigger,
ExposureStart, AcquisitionTrigger, SoftwareSignal0,
“oftwareSignal1, LogicBlock0, Action0
Default: Off
TimerTriggerActivation
IEnumeration
Type
Polarity of reference signal to generate “Timer active” signal
Selection: RisingEdge, FallingEdge
Default: RisingEdge”
When the timing of “Timer0active” signal is adjusting to active signal of Exposure, “Timer0” can be used as
strobe control signal.
Counter Control
GenICam Parameters
CounterSelector
IEnumeration
Type
Counter selection
Selection: Counter0, Counter1
Default: Counter0
CounterEventSource
IEnumeration
Type
Counter event source selection
Selection: Off, FrameStart, FrameTrigger
Default: Off
CounterResetSource
IEnumeration
Type
Reference signal selection to reset counter
Selection: Off, Line0, Line1, Line2
Default: Off
CounterResetActivation
IEnumeration
Type
Polarity of reference signal to reset counter
Selection: RisingEdge, FallingEdge
Default: RisingEdge
CounterReset
ICommand Type Reset switch
Activate as switch when selecting “Software” at “CounterResetSource”
CounterValue
IInteger Type
Returns number of counter