background image

Power Supply and Wiring

‡

Make sure to use the product with the power supply voltage 

specified by this manual.

‡

Use the specified wire size (AWG10 to 16).

‡

Keep the power supply wires as short as possible

(Max.2m).

‡

Use a DC power supply with safety measures against high-voltage 

spikes(safety extra low-voltage circuits on the secondary side).

‡'RWKHIROORZLQJFRQILUPDWLRQVDJDLQEHIRUHWXUQLQJRQWKHSRZHU

supply. 
 - Is the voltage and polarity of the power supply correct? (24VDC)
 - Is not the load of the output signal short-circuited?
 - Is the load current of the output signal appropriate?
 - Is not the mistake found in wiring?
 - Is the voltage and polarity of the encoder power(ENC0 VDD /    
   ENC0 GND / ENC1 VDD / ENC1 GND) supply ? (5VDC)

●Ground

‡

The power supply circuit of the FH Sensor Controller is insulated 

from the internal circuit.

‡

Be sure to use a base to install the camera connected with the FH 

Sensor Controller. Since the exclosure of the camera main body 
made of metals is short-circuited with the internal circuit, the 
internal circuit might be short-circuited with FG if no base is used, 
so that failures or malfunctions may be caused.

‡3HUIRUP&ODVV'JURXQGLQJZLWKDJURXQGLQJUHVLVWDQFHRIї

 or 

less).

‡

Keep the ground line as short as possible by setting the grounding 

point as close as possible.

‡

Ground the FH Sensor Controller independently. If sharing the 

ground line with other devices or connecting it with a building 
beam, the Sensor Controller might be adversely effected.

‡

Check wiring again before turning on the FH Sensor Controller.

‡'RQRWJURXQGWKHSOXVWHUPLQDORIWKH9'&SRZHUVRXUFH

   

when the FH Sensor Controllers are connected to the 

FH-SC12/FH-SM12 (12 megapixels).

   Doing so may cause a short circuit of the internal circuit,
  resulting in a malfunction.

‡'RQRWJURXQGWKHSOXVWHUPLQDORIWKH9'&SRZHUVRXUFH

   when the FH Sensor Controllers are connected to the FH-MT12
  with a USB cable. Doing so may cause a short circuit of the
  internal circuit, resulting in a malfunction.

Other

‡

Use only the camera and cables designed specifically for the 

product. Use of other products may result in malfunction or damage 
of the product.

Please insert DVI-I connector perpendicularly so that the connector 

resin part and pin are not rubbing against each other. Damaged pin 
may cause contact failure due to generation and invasion of resin 
powder.

‡

Always turn OFF the power of the FH Sensor Controller and 

peripheral devices before connecting or disconnecting a camera or 
cable. Connecting the cable with power supplied may result in 
damage of the camera or peripheral devices.

‡

For the cable that is flexed repeatedly, use the robotic cable type

  (Bend resistant camera cable) to prevent damages.

‡

Do not apply torsion stress to the cable. It may damage the cable.

‡

Secure the minimum bending radius of the cable. Otherwise the 

cable may be damaged.

‡

Do not attempt to dismantle, repair, or modify the product.

‡

Should you notice any abnormalities, immediately stop use, turn 

OFF the power supply, and contact your OMRON representative.

‡

The FH Sensor Controller and camera case are hot while power is 

supplied or directly after the FH Sensor Controller is turned off. Do 
not touch the case.

‡

Be sure to dispose of the product as industrial waste.

‡

Do not drop, impose excessive vibration or shock on the product. 

Doing so may result in malfunction or burning.

‡

Since a lithium battery is incorporated, there is a rare case when 

you are seriously injured due to firing or blowout.

Fail-safe measures, external to this system, should be in place to 

ensure safety when using Sensor Controller measurement results 
to control the movement of a robot and conveyor, or stage.

Regulations of KC marking

˙૶ૺૺˀ࿕ඳဧ෮໽ቛཅૺၴႁˁ

ၦૺૺ௴࿕ඳဧ˙૶႖ၴኒ႕ጁૺૺച໏ን൯ၴ

ವ௴ຫဧၴ௴ၦ႙ၕ჎ၡዻགྷૺ෡ೡඑਜ਼ႜဘၡ

ხ࿦࿝໏ຫဧዻ௴ઇၕඛ႕ၒചጁఁఋ

Image Processing System

FH-1050

FH-3050

FH-1050-

   

0

FH-3050-

   

0

Basic Configuration

Items indicated with an asterisk are dedicated items, and cannot be substituted.

*

*

Do not install in this orientation.

FFH-VMDA

(2m, 5m, 10m, min. bending radius 36mm)

FH-VMDA(2m, 5m, 10m, min. bending radius 36mm)

A

B

C

D

E

F

G
H

I

K

L

Ambient Temperature

‡

To keep proper air flow, keep the top of the FH Sensor Controller 

50mm or more apart from other devices. Install the FH Sensor 
Controller with a clearance of 30mm on the right and left side, and 
15mm for rear planes. The clearance is required for installing 
multiple units side-by-side.
Clearance is not required for the side mounting.

‡

Do not install the product immediately above significant heat 

sources, such as heaters, transformers, or large-capacity resistors.

‡

Do not let the ambient temperature exceed 50

(122°F).

‡

Provide a forced-air fan cooling or air conditioning if the ambient 

temperature is near 50

(122°F) so that the

ambient temperature never exceeds 50

(122°F).

Noise Resistance

‡

Do not install the product in a cabinet containing high-voltage 

equipment.

‡

Do not install the product within 200 mm of power cables.

Component Installation and Handling

‡

Touching Signal Lines

To prevent damage from static electricity, use a wrist strap or 
another device for preventing electrostatic discharges when 
touching terminals or signal lines in connectors.

‡

Handling a USB Memory/SD memory card

To remove a USB memory or SD memory card, make sure that 
data is not being read or written to it.

‡

For USB memory, the LED flashes while data is being read or 

written, so make sure that it is lit steadily before removing the 
memory.

‡

For SD memory card, the SD BUSY LED flashes while data is 

being read or written, so make sure that it is turned OFF before 
removing the memory.

‡

When you insert the SD memory card, please do not insert in the 

reverse, do not insert at an angle and do not insert while twisting.

‡

Turning OFF the Power

Do not turn OFF the power while a message is being displayed 
indicating that processing is being performed. Data in memory will 
be corrupted, and the product may not operate correctly the next 
time it is started.

Maintenance

‡7XUQ2))WKHSRZHUDQGWDNHVDIHW\SUHFDXWLRQVEHIRUH

conducting 

inspections. Electrical shock can result from attempting safety 
inspections with the power turned ON.

‡

Clean the lens with a lens-cleaning cloth or air brush.

‡

Lightly wipe off dirt with a soft cloth.

‡

Dirt on the image element must be removed using an air brush.

‡

Do not use thinners or benzene.

Communication with High-order Device

After confirming that this product is started up, communicate with 
the high-order device. When this product has started up, an 
indefinite signal may be output from the high-order interface. To 
avoid this problem, clear the receiving buffer of your device at initial 
operations.

Fail-Safe Measures

‡

If you wish to operate a stage and/or a robot using a measurement 

result from a FH Sensor Controller(e.g. axis movement amount 
output based on calibration/alignment measurement),always take 
safety measures so that the measurement result should be 
checked by the stage/robot if it is within the range of movement of 
the stage/robot before operation.

‡2QD)+6HQVRU&RQWUROOHUVLGHVXSSOHPHQWDULO\XVHRSHUDWLRQV

and branches of the FH Sensor Controller to configure a check 
flow such as “data should not be externally provided if the data 
is in a range from-XXXXX to XXXXX ”based on the stage/robot’s 
range of movement.

In case of connecting the sensor controller and monitor with a 

switcher and splitter:

Do not use devices that may require re-recognition of the 

monitor by the sensor controller. Re-recognizing the monitor 
during switch may slow the inspection speed down.

The power supply connected to FH Sensor 
Controller varies depending on the number of 
connected cameras and types for various 
consumption current types. Use is accordingly.

J

INSTRUCTION SHEET

Thank you for selecting OMRON product. This sheet pri-
marily describes precautions required in installing and
operating the product.
Before operating the product, read the sheet thoroughly to
acquire sufficient knowledge of the product. For your con-
venience, keep the sheet at your disposal.

TRACEABILITY INFORMATION:

Importer in EU

  Omron Europe B.V.

Wegalaan 67-69

2132 JD Hoofddorp,
The Netherlands

Manufacturer
  Omron Corporation,
  Shiokoji Horikawa, Shimogyo-ku,
  Kyoto, 600-8530 JAPAN

2013-2015

Meanings of Signal Words

Meanings of Alert Symbols

Alert statements in this Manual

The following alert symbols are used in this manual.

The following alert statements apply to the products in this 
manual. Each alert statement also appears at the locations 
needed in this manual to attract your attention.

Indicates a potentially hazardous 
situation which, if not avoided, will 
result in minor or moderate injury, or 
may result in serious injury or death. 
Additionally there may be significant 
property damage.

WARNING

Indicates a potentially hazardous 
situation which, if not avoided, may 
result in minor or moderate injury or in 
property damage.

Indicates general prohibitions for which there is 

no specific symbol.

Indicates the possibility of electric shock under 

specific conditions.

Indicates the possibility of explosion under 

specific conditions.

Indicates the possibility of laser radiation.

Indicates the possibility of injury by high 

temperature under specific conditions.

CAUTION

Symbols and the meanings for safety precautions 
described in this manual.

In order for the product to be used safely, the following 
indications are used in this book to draw your attention to 
the cautions. The cautions with the indications describe 
the important contents for safety.

Precautions for Safe Use

WARNING

CAUTION

This product must be used according to the 
instruction manual. Failure to observe this may 
result in impairment of functions and 
performance of the product.

This product is not designed or rated for 
ensuring safety of persons. Do not use it for 
such purposes.

Never connect the AC power supply with this
product. When the AC power supply is
connected, it causes the electric shock and a fire.

Do not touch the terminals while the power supply 
is ON. Doing so may result in electrical shock.

A lithium battery is built into the Sensor Controller 
and may occasionally combust, explode, or burn if 
not treated properly. Dispose of the Sensor Controller 
as industrial waste, and never disassemble, apply 
pressure that would deform, heat to 100

 or higher, 

or incinerate the Sensor Controller.

Since camera that can be connected with this 
product emits a visible light that may have an 
adverse effect on the eyes, do not stare directly 
into the light emitted from the LED. If a specular 
object is used, take care not to allow reflected 
light enter your eyes.

Please take external safety measures so that the
system as a whole should be on the safe side 
even if a failure of a Sensor Controlle

r

 or an error 

due to an external factor occurred.An abnormal
operation may result in serious accident.

Please take fail-safe measures on your side in
preparation for an abnormal signal due to signal
conductor disconnection and/or momentary
power interruption.An abnormal operation may
result in a serious accident.

Danger of burns. Do not touch the case while the 
LED is ON or just after power is turned OFF, 
since it remains extremely hot.

Installation Environment

‡

Do not use the product in areas where flammable or explosive 

gases are present.

‡

Install the product so that air can flow freely through its cooling vents.

‡

Clean the vent hole and discharge opening to prevent dust or 

particles from blocking them. Blocked cooling vents or discharge 
opening of the fan increasing heat inside, causing malfunction of 
the product.

‡

Do not install the product close to high-voltage devices and power 

devices in order to secure the safety of operation and 
maintenance.

‡

Make sure to tighten all installation screws securely.

Precautions for Correct Use

Installation and Storage Sites

Install and store the product in a location that meets the following 
conditions:

‡

Surrounding temperature of 0 to 50

WR

 in storage)

‡

No rapid changes in temperature (place where dew does not form)

‡

Relative humidity of between 35 to 85 %

‡

No presence of corrosive or flammable gases

‡

Place free of dust, salts and iron particles

‡

Place free of vibration and shock

‡

Place out of direct sunlight

‡

Place where it will not come into contact with water, oils or 

chemicals

Orientation of Product

To keep proper ventilation, install the main unit only in the 
direction below so that the ventilation holes are not blocked.

Sensor controller

The Sensor Controller performs the image  processing 
specified by the user settings and outputs the measurement 
results.

Camera 4ch type

FH-3050-10
FH-1050-10

Camera 8ch type

FH-3050-20
FH-1050-20

Camera 2ch type

FH-3050
FH-1050

LCD monitor

Use the monitor to check images and
display the condition-setting menus.

Use the monitor to check images and
display the condition-setting menus.

FZ-M08(8.4inch)

Monitor cable

Monitor cable

Camera cable
FZ-VS3(2m

,

3m

,

5m

,

10m

,

min.bending radius: 69mm)

Bend resistant Camera cable
FZ-VSB3(2m

,

3m

,

5m

,

10m

,

min.bending radius: 69mm)

Right-angle Camera cable
FZ-VSL3(2m

,

3m

,

5m

,

10m

,

min.bending radius: 69mm)

Bend resistant Right-angle Camera cabe
FZ-VSLB3(2m

,

3m

,

5m

,

10m

,

min.bending radius: 69mm)

Long-distance Camera cable
FZ-VS4(15m

,

min.bending radius: 78mm)

Long-distance Right-angle Camera cable
FZ-VSL4(15m

,

min.bending radius: 78mm)

Camera cable

Camera

Standalone camera
FZ-SC/FZ-S/
FZ-SC2M/FZ-S2M/
FZ-SFC/FZ-SF/
FZ-SPC/FZ-SP/
FZ-SHC/FZ-SH/
FH-SC/FH-SM/
FH-SC02/FH-SM02/
FH-SC04/FH-SM04/
FZ-SC5M2/FZ-S5M2/
FH-SC12/FH-SM12

Intelligent compact camera
FZ-SQ010F/FZ-SQ050F/
FZ-SQ100F/FZ-SQ100N

Detects workpieces as images.

Power Supply

Peripheral Device

Input Device

USB memory
FZ-MEM2G
FZ-MEM8G

SD memory card
HMC-SD291
HMC-SD491

Mouse, keyboard
(Commercially available 
 USB driverless wired devices)

Recommended Model by OMRON:
S8VS series
S8VS-09024, S8VS-12024
S8VS-18024

S8VS-24024

S8VS-48024

Connector name

Description

SD memory card installation connector Install the SD memory card. 

Do not plug or unplug the SD memory card during measurement 

operation. Otherwise measurement time may be affected or data may be destroyed.

Ethernet connector

Connect an Ethernet device.

USB connector

Connect a USB device. Do not plug or unplug it during measurement and accessing 
USB device. Measurement time might be affected otherwise.

RS-232C connector

Connect an external device such as a PLC.

Monitor connector

Connect a monitor.

I/O(Parallel) connector(control lines, data lines) Connect the controller to external devices such as a sync sensor and PLC.

EtherCAT address setup volume

Used to set a station address ( 00 to 99) as an EtherCAT communication device.

EtherCAT communication connector (IN)

Connect the opposed EtherCAT device.

EtherCAT communication connector (OUT) Connect the opposed EtherCAT device.

Camera connector

Connect cameras.

Power supply terminal connector

Connect a DC power supply. Wire the FH Sensor Controller independently on other devices.   
Wire the ground line. Be sure to ground the FH Sensor Controller alone. Perform wiring using 
the attached terminal block connector (FH-XCN) as referring to the description of wiring that connector.

A

B

C

D

E
F

G
H

I

K

Encoder connector

Connect an encoder.

J

L

■ 

Component Names and Functions

LED name

Description

POWER

 

LED

Lit while power is ON.

ERROR LED

Lit when an error has occurred.

RUN

 

LED

Lit while the layout turned on output setting is displayed.

ACCESS

 

LED

Blinks while the internal nonvolatile memory is accessed. 

SD

 

POWER

 

LED

Lit while power is supplied to the SD memory card and the card is usable.

SD

 

BUSY

 

LED

Blinks while the SD memory card is accessed.

EtherCAT RUN LED

Lit while EtherCAT communications are usable.

EtherCAT LINK/ACT IN LED

Lit when connected with an EtherCAT device, and blinks while performing communications.

Lit when connected with an EtherCAT device, and blinks while performing communications.

EtherCAT LINK/ACT OUT LED

Lit when EtherCAT communications have become abnormal.

EtherCAT ERR LED

Lit when Ethernet communications are usable.

Ethernet NET RUN1 LED

Lit while Ethernet communications are usable.

Ethernet NET LINK/ACK1 LED

Lit when connected with an Ethernet device, and blinks while performing communications.

Ethernet NET RUN2 LED
Ethernet NET LINK/ACK2 LED

Lit when connected with an Ethernet device, and blinks while performing communications.

*

*

*

*

*

*

Camera 2ch type

Camera 4ch / 8ch type

Ethernet port and 
EtherNet/IP port are 
sharing use.

Upper port : 
Ethernet port
Lower port :
Ethernet port and 
EtherNet/IP port are 
sharing use.

9607479-9B

Touch panel monitor

FH-MT12

12.1inch

FH-VUAB

USB type, 2m, 5m, min. bending radius: 25mm

XW2Z-

□□□

PP-1

RS-232Ctype, 2m, 5m, 10m min. bending radius: 59mm

Touch panel cable

Switcher
In case of switching multiple of sensor 
controllers with a single monitor or 
touch panel monitor, please make sure 
to use an appropriate product.
Recommended model 
by OMRON: FZ-DU