![background image](http://html1.mh-extra.com/html/omron/f3s-tgr-sb2-kxc/f3s-tgr-sb2-kxc_user-manual_744119009.webp)
2-2 Reflecting surfaces
9
2-2
Reflecting surfaces
!
Be sure to install the SLC to minimize the effect of reflection from nearby surfaces. Serious injuries
can result if these effects are not taken into consideration.
Should there be any reflecting surfaces, the distance must be sufficient to safeguard against passive
reflections.
The distance can be calculated following the table below:
where 'D' and 'L' are expressed in m
Reflecting surface
Model
L distance between SLCs
Minimum permitted installation distance D
F3S-TGR-SB2-KxC
0.5 to 3 m
0.26 m
Over 3 m
L/2 x tan5° = L/2 x 0.088 (m)
F3S-TGR-SB4-KxC
0.5 to 3 m
0.13 m
Over 3 m
L/2 x tan5° = L/2 x 0.044 (m)