background image

G-53

F3S-TGR-SB

@

C series

F3S-TGR

Rating and Performance

Safety sensors

F3S-TGR-SB

@

-K

@

C

Muting Connecting Box

F3S-TGR-SB-CMB

@

Item

Model

F3S-TGR-SB4-K

@

C-

@@@

(MTL)*

*.  If you want to have a ONE WAY direction Type, (see Page D-26) Please add the MTL behind of Model Name. Ex. F3S-TGR-SB4-K2C-500MTL

F3S-TGR-SB2-K

@

C-

@@@

(MTL)*

Sensor type

Type 4

Type 2

Applicable safety category

4, 3, 2, 1, B

2, 1, B

Operating range

F3S-TGR-SB

@

-K2C

0.5 - 6 m

F3S-TGR-SB

@

-K3C/K4C

0.5 - 6 m

Beam pitch and Number of beam

F3S-TGR-SB

@

-K2C

500 mm

2 beam with mirror

F3S-TGR-SB

@

-K3C

400 mm

3 beam with mirror

F3S-TGR-SB

@

-K4C

300 mm

4 beam with mirror

Outermost beam gap

F3S-TGR-SB

@

-K2C

500 mm

F3S-TGR-SB

@

-K3C

800 mm

F3S-TGR-SB

@

-K4C

900 mm

Effective aperture angle (EAA)

Within ±2.5°

Within ±5°

Light source

Infrared LED (880 nm)

Power supply

24 VDC ± 20%

Current Consumption

420 mA

OSSD

Two PNP transistor outputs, 250 mA each. (500 mA sum)

Output operation mode

Light - ON

Test functions

Self-test (after power ON and during operation, one cycle during response time)

Protection

Output short-circuit protection, Reverse Polarity protection

Response time

ON to OFF 16ms max
OFF to ON 300 ms (Maximum Power-ON time is 900 ms)

Ambient temperature

Operating: -10 to +55 °C (with no dew condensation)

Ambient humidity

15% to 95% (non condensing)

Metal housing (Al) painted

Yellow (RAL 1303 F14)

Degree of protection

IP65

Accessories

M6 T-Bolt x 8, M6 Nut x 8
Mounting fixture x 4

Applicable standards

EN61496-1; 1997
prEN61496-2; 1997

Item

Model

F39-TGR-SB-CMB

@

Power supply

24 VDC ± 20%

Consumption

10 W max

Ambient temperature

During operation: -10 to +55 °C (with no dex condensation)

Ambient humidity

15% to 95% (non condensing)

RX connector

M12 8 pins female

Cabinet connector

M12 8 pins male

Sensor connector

4 x M12 4 pins female

Muting indicator

M12 4 pins female

Test / Override connectors

M12 4 pins female

Metal housing (Al) painted

Yellow (RAL 1303 F14)

Degree of protection

IP65

Material

Case

Aluminium

Connector

Brass with nickel plate

Front Cover

Aluminium

Weight

0.5 kg

Accessories

M6 T-Bolt x 4, M6 Nut x 4
Mounting fixture x 2, Connector cover x 2

F502-EN2-04.book  Seite 53  Dienstag, 26. Juli 2005  5:48 17

Summary of Contents for F3S-TGR-SB -

Page 1: ...achieve an active passive multi beam system This active passive system will improve installation time and reduce costs 3 Different types available We provide 3 different Types as following 2 beam Type beam pitch 500 mm 3 beam Type beam pitch 400 mm 4 beam Type beam pitch 300 mm Muting functions are integrated Following Muting functions are integrated Muting sensor inputs Muting Lamp output Overrid...

Page 2: ...and the E3G datasheet Cat No E278 E2 Cat04 03 SOLUTION 1 Object Gaps In many palletiser applications there is a gap between objects on the pallet The Muting function may not work correctly because of this gap To avoid the mutual interruption we recommend to Use E3G T as muting sen sor E3G T has ON delay timer internally 0 to 5 seconds SOLUTION 2 Misalignment of pallets When using a CROSS MUTING sy...

Page 3: ... 500 MTL If you want to have a ONE WAY direction Type see Page D 26 Please add the MTL behind of Model Name Ex F3S TGR SB4 K2C 500MTL 3 400 F3S TGR SB4 K3C 800 MTL 4 300 F3S TGR SB4 K4C 900 MTL Appearance SLC Connection Type Other connection Model M12 8pin connector without cable 4 x Muting sensor connection 4pin 1 x Muting Lamp M12 4pin 1 x Override Test input M12 4pin 1 x cabinet connection M12 ...

Page 4: ...it Appearance Cable connection direction Specification Connection method Applicable cable diameter Model Straight DC only 4pin Plug Screw on 3 dia 3 to 4 dia XS2G D4S5 Right angle XS2G D4S6 Appearance Specification Model 24 V DC F39 A11 Appearance Specification Model 24 V DC 3 W E14 F39 A11MB Appearance Model F39 LKK2 SB ...

Page 5: ...after power ON and during operation one cycle during response time Protection Output short circuit protection Reverse Polarity protection Response time ON to OFF 16ms max OFF to ON 300 ms Maximum Power ON time is 900 ms Ambient temperature Operating 10 to 55 C with no dew condensation Ambient humidity 15 to 95 non condensing Metal housing Al painted Yellow RAL 1303 F14 Degree of protection IP65 Ac...

Page 6: ...s Applicable standards 93 68 EEC DIN V VDE 0801 1990 and am A1 1994 EN 50081 2 1993 EN 55022 1998 Model A C E F3S TGR SB K2C500 614 mm 500 mm 500 mm F3S TGR SB K3C800 914 mm 800 mm 400 mm F3S TGR SB K4C900 1 014 mm 900 mm 300 mm Item Model F39 TGR SB CMB 47 5 37 7 35 13 73 C E A ...

Page 7: ...GR SB CMB1 Muting connection box Mounting bracket Common bracket for F3S TGR SB K C and F39 TGR SB CMB Connector Plug Assemblies Screw on Type XS2G D4S5 XS2G D4S6 14 dia 58 7 14 9 dia 20 dia M12 x 1 39 6 39 7 14 9 dia 20 dia 14 dia M12 x 1 ...

Page 8: ...c Blue 8 Muting Lamp 0 Vdc Red White Brown Green Yellow Pink Gray Blue Red Shield 24Vdc 0Vdc Active side Passive side S1 When using Muting function S1 External Test Interlock reset Switch MIA Muting input A MIB Muting input B ML Muting Lamp OSSD1 OSSD2 White Brown Green Yellow Pink Gray Blue Red Shield 24Vdc 0Vdc S1 MIA MIB ML OSSD1 OSSD2 In case of Cat 4 EN954 1 OSSD1 2 must be connected Safety R...

Page 9: ...ctor with 100 mm cable Front View Pin No Signal Name Wire Color 1 Test and Reset Input White 2 24 Vdc Brown 3 Muting A Input Green 4 Muting B Input Yellow 5 OSSD1 OUT1 Gray 6 OSSD2 OUT2 Pink 7 0 Vdc Blue 8 Muting Lamp 0 Vdc Red Front View Pin No Signal Name Wire Color 1 24 Vdc Brown 2 No connect White 3 0 V Blue 4 PNP Input Black Front View Pin No Signal Name Wire Color 1 24 Vdc Brown 2 No connect...

Page 10: ...erride N O Brown Common Muting sensor B2 Muting sensor A2 Muting sensor B1 Muting sensor A1 Muting Lamp Override Switch Test Reset Switch F39 TGR SB CMB Plug reference KM1 KM2 KM1 b KM2 b 1 2 3 4 ON 1 2 3 4 ON DIP switch Status of F3S TGR SB K C Manual Reset Mode Every DIP SW has to be OFF status Factory setting Auto Reset Mode Sw No 4 is ON G9SB 301 B Passive side Active side In the interest of p...