Safety Precautions

Application Precautions

• Do not use the product in locations subject to explosive or 

flammable gases.

• Do not use load currents exceeding the rated value.
• Be sure to wire each conductor correctly.
• Be sure to confirm correct operation after completing mounting and 

adjustment.

• Do not drop or attempt to disassemble the product.
• Be sure to use the correct combination of switch and actuator.
• Use a power supply of the specified voltage. Do not use power 

supplies with large ripples or power supplies that intermittently 
generate incorrect voltages.

• Capacitors are consumable and require regular maintenance and 

inspection.

Precautions for Safe Use

Mounting Direction of Switch and Actuator

The Sensor will not operate properly if the switch and actuator come 
towards each other diagonally. The Sensor will, however, operate 
properly if the switch and actuator come towards each other head-
on, horizontally or vertically (as long as the faces have the same 
orientation). 

Mutual Interference

If the switch and actuator are mounted in parallel, be sure to 
separate them by at least 25 mm, as shown below.

Using for Hinged Doors

On hinged doors, install the Sensor at an opening edge as shown 
below.

Solvents

Ensure that solvents, such as alcohol, thinner, trichloroethane, or 
gasoline do not adhere to the product. Solvents may cause markings 
to fade and components to deteriorate.

Installation Location

Do not install the product in the following locations. Doing so may 
result in product failure or malfunction.

• Locations subject to direct sunlight
• Locations subject to humidity levels outside the range 35% to 85% 

or subject to condensation due to extreme temperature changes

• Locations subject to corrosive or flammable gases
• Locations subject to shocks or vibration in excess of the product 

ratings

• Locations subject to dust (including iron dust) or salts

Take appropiate and sufficient countermeasures when using the 
product in the following locations.

• Locations subject to static electricity or other forms of noise
• Locations subject to possible exposure to radioactivity
• Locations subject to power supply lines
• It is advisable to mount the switches on non ferrous materials. 

The presence of ferrous material can effect switching sensitivity.

Wiring

Perform wiring using wire with the following dimensions.

Stranded wire: 2.5 mm

2

Solid wire:

4.0 mm

2

Tighten the terminal screws with the specified torque. Not doing so 
may result in malfunction or abnormal heat generation.

Terminal screw tightening torque: 1 Nm for NLPC and NSMC

0,8 Nm for NMPC

Be sure to turn OFF the power before performing wiring. 
Do not touch charge parts (e.g., terminals) while power is 
ON. Doing so may result in electric shock.

Do not allow the actuator to come close to the switch with 
the door open. Doing so may cause machinery to start 
operating and may result in injury.

Keep actuators (magnets) away from magnetically 
sensitive equipment like PC harddisks, floppy disks etc. 
The magnetic field of the magnet will damage existing 
data.

Use guard stops in the way shown below to ensure that 
the switch and actuator do not make contact when the 
guard door is closed.

 

!WARNING

 

!

CAUTION

min. 2 mm
max. 5 mm 

(Standard Sensor)

max. 4 mm (Elongated Sensor)

Guard door

Guard Stops

Switch

Actuator

CORRECT

INCORRECT

CORRECT

CORRECT

25 mm min.

Switch

Switch

Actuator

Guard door

Actuator

2 mm

CORRECT

INCORRECT

E14E-EN-02+F3S-TGR-N_C+CDatasheet.fm  Seite 11  Montag, 25. August 2008  10:56 10

Summary of Contents for F3S-TGR-N C -

Page 1: ...C Conforms to safety categories up to 4 acc EN 954 1 and PDF M acc EN60947 5 3 Model Number Structure 1 Type L Elongated Sensor S Small Sensor for NLPC and NSMC M Miniature Sensor 2 Housing Material P...

Page 2: ...0 05 Preferred stock items 5 m pre wired 2NC F3S TGR NSMC 20 10 10 pre wired 2NC F3S TGR NSMC 20 M1J8 M12 8 pin 2NC F3S TGR NSMC 21 02 2 m pre wired 2NC 1NO F3S TGR NSMC 21 05 5 m pre wired 2NC 1NO F3...

Page 3: ...ontroller 16 inputs NE1A SCPU01L Standalone controller 40 inputs NE1A SCPU02L Safety Network controller 16 inputs NE1A SCPU01 V1 Safety Network controller 40 inputs NE1A SCPU02 Safety input terminal D...

Page 4: ...rotection Flying lead M12 connector IP67 Material Black Polycarbonate Stainless Steel 316 Black Polyester Mounting bolts 2 x M4 recommended Tightening torque 1Nm 0 8Nm Mounting position any Mechanical...

Page 5: ...1 NO Channel NC Channel 2 GND NC Channel 1 NO Channel NC Channel 2 Pin No Signal name Brown Green White Blue Yellow Pink Grey Red 2 3 1 7 4 6 5 8 Pin No Signal name Wire color F39 TGR SB4 CVLB 24 VDC...

Page 6: ...r F3S TGR NLPC Small Sensor Sensor Actuator F3S TGR NSMC Miniature Sensor Sensor Actuator F3S TGR NMPC 88 78 4 50 3 50 7 25 88 78 18 50 25 5 20 13 3 13 3 22 25 50 21 3 4 20 50 4 50 13 22 25 50 50 4 20...

Page 7: ...M1 KM2 Start Feed back loop 13 14 33 34 Us GND red blue white black yellow green F3S TGR NxxC Sensor Magnetic Actuator KM1 KM2 M KM1 KM2 G9SA 301 brown orange NO contact F3S TGR NxxC Sensor Magnetic A...

Page 8: ...2 T31 T32 KM1 KM2 Start Feed back loop 13 14 Us GND red blue white black yellow green M KM1 KM2 brown orange NO contact G9SB 2002 C KM1 KM2 23 24 F3S TGR NxxC Sensor Magnetic Actuator F3S TGR NxxC Sen...

Page 9: ...d blue white black yellow green F3S TGR NxxC Sensor Magnetic Actuator M KM1 KM2 brown orange NO contact G9SX AD322 A1 T33 S14 S24 GND KM1 KM2 24V GND T11 T12 T22 T21 T31 T32 KM1 KM2 Start Feed back lo...

Page 10: ...Sensor Magnetic Actuator 24V GND red blue white black yellow green F3S TGR NxxC Sensor F3S TGR NxxC Sensor F3S TGR NxxC Sensor red blue white black yellow green red blue white black yellow green V0 G...

Page 11: ...idity levels outside the range 35 to 85 or subject to condensation due to extreme temperature changes Locations subject to corrosive or flammable gases Locations subject to shocks or vibration in exce...

Page 12: ...est of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounc...

Reviews: