8
Safety Sensors / Components
G9SB
Single Sensor Application with G9SB-2002-C
(up to Safety Category 4 acc. EN954-1)
Series connection Application, up to 6 Sensors with G9SB-2002-C
(up to safety Category 3 acc. EN954-1)
F3S-TGR-NxxC
Sensor
Magnetic
Actuator
+24V
GND
A1
A2
T11
T12
T21
T22
T31
T32
KM1
KM2
Start
Feed-
back-
loop
13
14
+Us
GND
red
blue
white
black
yellow
green
M
KM1
KM2
brown
orange
NO
contact
G9SB-2002-C
KM1
KM2
23
24
F3S-TGR-NxxC
Sensor
Magnetic
Actuator
F3S-TGR-NxxC
Sensor
Magnetic
Actuator
F3S-TGR-NxxC
Sensor
Magnetic
Actuator
+24V
GND
A1
A2
T11
T12
T21
T22
T31
T32
KM1
KM2
Start
Feed-
back-
loop
13
14
red
blue
white
black
yellow
green
M
KM1
KM2
red
blue
white
black
yellow
green
red
blue
white
black
yellow
green
+Us
GND
G9SB-2002-C
KM1
KM2
23
24
E14E-EN-02+F3S-TGR-N_C+CDatasheet.fm Seite 8 Montag, 25. August 2008 10:56 10