F3M-S

F3M-S

7

J

F3M-S1213

J

F3M-S1225

Optical axis

Two, M4, depth: 8
(mounting holes)

OMRON XG4A-3034
Connector

Teaching button

RUN/TEACH mode selector

Warning indicator

Teaching indicator

Power indicator

Optical axis

Optical axis

Two, M4, depth: 8
(mounting holes)

OMRON XG4A-3034
Connector

Teaching button

RUN/TEACH mode selector

Warning indicator

Teaching indicator

Power indicator

Optical axis

Optical axis

Optical axis

50

(1.97)

140 (5.51)

25 (0.98)

18 (0.71)

50

(1.97)

260 (10.24)

25 (0.98)

18 (0.71)

Precautions

J

CORRECT USE

Avoid Damage to the F3M-S

x

Do not use the F3M-S at a voltage that exceeds the rated
voltage range.

x

Do not make mistakes in wiring, such as mistakes in polarity.

x

Do not short-circuit the load.

x

Do not connect AC to the F3M-S.

J

INSTALLATION/ENVIRONMENT

Do NOT use the F3M-S in the following places:

x

Places exposed to direct sunlight.

x

Places with high humidity that may cause condensation.

x

Places with corrosive gas.

x

Places with vibration or shock directly affecting the Sensor.

J

CONNECTION AND MOUNTING

x

A maximum of 24 VDC+10% can be imposed on the F3M-S.
Check that the voltage of the power supply is within the per-
missible range before turning on the F3M-S. The power sup-
ply must be constructed so that the secondary circuit is insu-
lated with an isolating transformer.

x

Do not wire power lines or high-tension lines within the same
conduit with the lines of the F3M-S, or the F3M-S may be
damaged or malfunction due to induction. You must wire the
lines of the F3M-S separate from power lines or high-tension
lines or laid in an separate, shielded conduit.

x

Avoid mechanical impact when mounting the F3M-S, or the
water-resistant properties of the F3M-S will be reduced.

J

CLEANING

Do not attempt to clean the F3M-S using paint thinner, to avoid
damaging the surface of the F3M-S.

J

POWER SUPPLY

If a standard switching power supply is connected to the F3M-S,
be sure to ground the FG (frame ground) and G (ground)
terminals of the power supply. The F3M-S may malfunction due
to switching noise that will be generated from the power supply if
these terminals are not grounded.

Summary of Contents for F3M-S Series

Page 1: ...s with a Transparency of 92 F3M S6j and F3M S8j The F3M S allows the mapping of cassettes that have both silicon wafers and glass wafers The F3M S also accurately detects dummy wafers in the carrier u...

Page 2: ...Green indicator is ON when power is being supplied Warning Red indicator is ON under the following conditions Teaching no sensing object insufficient light or error Response time 10 ms max Control out...

Page 3: ...icator Warning indicator Teaching button RUN TEACH mode selector Teaching indicator The remote or manual automatic teaching of the F3M S is possible with the following two sensitivity settings 1 Max S...

Page 4: ...ent 1 GND 0 V 16 OUT14 2 VCC 12 to 24 V 17 OUT15 3 OUT1 18 OUT16 4 OUT2 19 OUT17 5 OUT3 20 OUT18 6 OUT4 21 OUT19 7 OUT5 22 OUT20 8 OUT6 23 OUT21 9 OUT7 24 OUT22 10 OUT8 25 OUT23 11 OUT9 26 OUT24 12 OU...

Page 5: ...ons 50 1 97 18 5 0 71 135 5 31 14 0 55 3 94 4 72 50 1 97 18 5 0 71 135 5 31 14 0 55 3 94 4 72 J F3M S625 J F3M S626 J F3M S825 J F3M S826 Optical axis Side mark Thirty 19 0 08 dia vinyl insulated flat...

Page 6: ...vibration or shock directly affecting the Sensor J CONNECTION AND MOUNTING x A maximum of 24 VDC 10 can be imposed on the F3M S Check that the voltage of the power supply is within the per missible ra...

Page 7: ...ne East Commerce Drive Schaumburg IL 60173 NOTE DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters to inches divide by 25 4 1 800 55 OMRON OMRON CANADA INC 885 Milner Avenue Scarborough Ontari...

Reviews: