background image

F3M-S

F3M-S

6

Dimensions

Unit: mm (inch)

Two, R4

Two, M4

Thirty, (19/0.08 dia.)
vinyl-insulated, flat
bending cable
Width: 38.1
Pitch: 1.27

Optical axis

Side mark

Two,
4.2-dia.
mounting
holes

Teaching button

RUN/TEACH
mode selector

Warning indicator

Teaching indicator

Power indicator

Mounting Dimensions

Two, M4

OMRON XG4E-3031
Connector

Two,
4.2-dia.
mounting
holes

Thirty, (19/0.08 dia.)
vinyl-insulated, flat
bending cable
Width: 38.1
Pitch: 1.27

OMRON XG4E-3031
Connector

Optical axis

Side mark

Teaching button

RUN/TEACH
mode selector

Warning indicator

Teaching indicator

Power indicator

Mounting Dimensions

50

(1.97)

18.5 (0.71)

135 (5.31)

14 (0.55)

(3.94)

(4.72)

50

(1.97)

18.5 (0.71)

135 (5.31)

14 (0.55)

(3.94)

(4.72)

J

F3M-S625

J

F3M-S626

J

F3M-S825

J

F3M-S826

Optical axis

Side mark

Thirty, (19/0.08 dia.)
vinyl-insulated, flat
bending cable
Width: 38.1
Pitch: 1.27

Two,
4.2-dia.
mounting
holes

OMRON XG4E-3031
Connector

Teaching button

RUN/TEACH mode selector

Warning indicator

Teaching indicator

Power indicator

Mounting Dimensions

Two, R5

Two, M4

Optical axis

Side mark

Thirty, (19/0.08 dia.)
vinyl-insulated, flat
bending cable
Width: 38.1
Pitch: 1.27

Two,
4.2-dia.
mounting
holes

Teaching button

RUN/TEACH mode selector

Warning indicator

Teaching indicator

Power indicator

Mounting Dimensions

Two, R5

Two, M4

OMRON XG4E-3031
Connector

50

(1.97)

18.5 (0.71)

170 (6.69)

14 (0.55)

(3.94)

(6.30)

50

(1.97)

18.5 (0.71)

175 (6.89)

14 (0.55)

(3.94)

(6.30)

Summary of Contents for F3M-S Series

Page 1: ...s with a Transparency of 92 F3M S6j and F3M S8j The F3M S allows the mapping of cassettes that have both silicon wafers and glass wafers The F3M S also accurately detects dummy wafers in the carrier u...

Page 2: ...Green indicator is ON when power is being supplied Warning Red indicator is ON under the following conditions Teaching no sensing object insufficient light or error Response time 10 ms max Control out...

Page 3: ...icator Warning indicator Teaching button RUN TEACH mode selector Teaching indicator The remote or manual automatic teaching of the F3M S is possible with the following two sensitivity settings 1 Max S...

Page 4: ...ent 1 GND 0 V 16 OUT14 2 VCC 12 to 24 V 17 OUT15 3 OUT1 18 OUT16 4 OUT2 19 OUT17 5 OUT3 20 OUT18 6 OUT4 21 OUT19 7 OUT5 22 OUT20 8 OUT6 23 OUT21 9 OUT7 24 OUT22 10 OUT8 25 OUT23 11 OUT9 26 OUT24 12 OU...

Page 5: ...ons 50 1 97 18 5 0 71 135 5 31 14 0 55 3 94 4 72 50 1 97 18 5 0 71 135 5 31 14 0 55 3 94 4 72 J F3M S625 J F3M S626 J F3M S825 J F3M S826 Optical axis Side mark Thirty 19 0 08 dia vinyl insulated flat...

Page 6: ...vibration or shock directly affecting the Sensor J CONNECTION AND MOUNTING x A maximum of 24 VDC 10 can be imposed on the F3M S Check that the voltage of the power supply is within the per missible ra...

Page 7: ...ne East Commerce Drive Schaumburg IL 60173 NOTE DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters to inches divide by 25 4 1 800 55 OMRON OMRON CANADA INC 885 Milner Avenue Scarborough Ontari...

Reviews: