background image

2

F3E

 Multibeam sensor

Rating/Specifications

ItemType

F3E-16-T[..]

F3E-46-T[..]

Rated sensing distance

0-5 m

Number LEDs

16

46

Number of optical axis

46

136

Resolution

120 mm

40 mm

Vertical detection area

1

1

other sizes available on request

20-1820 mm

Response time

max. 110ms (signal interruption)

Light source (wave length)

Infrared LED (880 nm)

Power supply voltage

10-30 VDC

Current consumption

max. 120 mA / pair

max. 240 mA / pair

Control output

Wearless potential free output, 35 V AC/DC max., 150mA max. at 20°C, 100mA max. 
at 60°C, D-ON (parameterization by emitter test input), max. leakage at open contact 
0,001mA, contact resistance 4/12 Ohm

Test input / light emission stop function

110 ms max. response time

Ambient light immunity 

2

2

Measured at angle of 20°

200.000 lux

Ambient temperature

-20…+60°C (operation) 

3

, -40…+70 (storage)

3

No icing and condensation

EMC conformity/standards

73/23/EWG; 89/336/EWG; 95/16/EG; EN81-1; EN81-2; EN12015; EN12016; 
EN61000-6-x

Protective degree

IP54

Connection methods

Pre-wire type (5 m PVC cable), M8-4-PIN

Indicator LEDs

Emitter: power indicator (yellow); 
Receiver: output indicator (yellow), output indicator (red)

Error status indication

Red LED blinking: unstable operation, contamination, max. exceeding sensing dis-
tance
Red LED ON + yellow LED ON: beam channel defect

Dimension

1

2070x40,7x9 mm

2000x40,7x9 mm

Weight

880g (connector version), 1040g (cable version)

Material

Case

Aluminum

Cable

PVC

A = c

u

rrent 

s

c

a

nning r

a

di

us

A/2

A/

3

A/

3

protected 

a

re

a

B

C

C

D

High resolution is realized by 

triple crossing of light 

beams

.

Automatic sensitivity control

 ensures steady and op-

timum light power. Even when sensors are operated 
in dirty environment or at highest distances, no ad-
justment is necessary. Sensitivity control ensures 
that the high resolution is maintained at small dis-
tances close to "zero".  

Min. size of recognized objects:

Pitch

B

D

C

120 mm

125 mm

65 mm

45 mm

40 mm

45 mm

35 mm

18 mm

Summary of Contents for F3E

Page 1: ...ceiver cut off can be monitored by control unit Ray failure toleration As soon as one channel is not switching for more than 60 seconds the F3E identifies a defect and deac tivates this channel The sensor then functions normally again showing the defect channel by a red error LED Easy parameterization By test input of transmitter a parameterization of L ON D ON operation and shading of LED areas i...

Page 2: ...conformity standards 73 23 EWG 89 336 EWG 95 16 EG EN81 1 EN81 2 EN12015 EN12016 EN61000 6 x Protective degree IP54 Connection methods Pre wire type 5 m PVC cable M8 4 PIN Indicator LEDs Emitter power indicator yellow Receiver output indicator yellow output indicator red Error status indication Red LED blinking unstable operation contamination max exceeding sensing dis tance Red LED ON yellow LED ...

Page 3: ...er 1 2 3 4 Connector PIN Arrangement Power indicator green 1 2 3 4 10 to 30 V DC 0 V brown white black not used blue Main circuit alternatively test input and programming Transmitter 1 2 3 4 Connector PIN Arrangement a1 a2 a3 a4 a5 h LED red light rays LED yellow 9 8 7 6 5 4 3 2 1 5 5 ø 4 5 Dimension F3E 16 F3E 46 a5 25 mm 25 mm a4 690 mm 650 mm a3 640 mm 650 mm a2 690 mm 650 mm a1 25 mm 25 mm h 2...

Page 4: ...m line angled M8 PVC 4 5 no brass XS3F M422 405 A robotic cable straight M8 PVC 4 5 no brass XS3F M421 405 R robotic cable angled M8 PVC 4 5 no brass XS3F M422 405 R Item Description Order reference F3E Installation Kit S Installation kit for stationary mounting on lift doors F3E IK S F3E Installation Kit M Installation kit for mounting to mobile doors panels F3E IK M F3E Power supply Power supply...

Page 5: ...wer mounting angle sensor unit with mounting strap fixation The upper mounting angle is screwed to the top of the door operator The lower mounting angle is screwed to the underside of the door sill Then the vertical mounting angle with the sensor unit already screwed onto it is inserted with its conical end into the slot in the lower mounting angle sensor unit with strap fixation mounting clamps d...

Page 6: ...nsor Do not strike the Photoelectric Sensor with a hammer or any other tool during the installation of the Sensor Cleaning Never use paint thinners or other organic solvents to clean the surface of the product M8 Connector Always turn OFF the power supply to the Sensor before con necting or disconnecting the metal connector Hold the con nector cover to connect or disconnect it Secure the connector...

Reviews: