40
Troubleshooting
Section 5-1
5-1
Troubleshooting
5-1-1
Connection Errors
5-1-2
Menu Operation Errors
5-1-3
Parallel Interface Errors
Problem
Probable cause
The POWER indicator is not lit.
The Power Supply is not connected properly.
The supply voltage is not 24 VDC
+10%
/
-15%
.
The Monitor is blank.
The power to the Monitor is not ON.
The Monitor Cable is not connected properly.
The Monitor is malfunctioning.
The power supply capacity is insufficient.
The Video Monitor image is not
clear.
There is electrical noise entering from the power supply or cables.
The Monitor Cable is not correctly connected.
Cannot make key inputs from the
Console.
The Console Cable is not correctly connected.
Camera images do not appear on
the screen (for Cameras with Light
Source).
The Camera Cable is not correctly connected.
The lighting cable is not properly connected to the Camera.
Camera images do not appear on
the screen (when a standard CCTV
lens and lighting are used).
The lens cap has not been removed.
The Camera Cable is not properly connected.
The lens iris is opened or closed too far.
The shutter speed is not suitable.
The lighting method is not suitable.
The indicators do not turn ON (for
Cameras with Light Source).
The lighting cable is not correctly connected to the Camera.
Power is not being supplied to the F160.
When using a Camera with Intelligent Lighting, the DIP switch pins are not
set to 0.
When using an F160-S2 Camera with Intelligent Lighting, the number of
lines is not set to 484.
Problem
Probable cause
The measurement results are not
displayed on the Monitor.
The F160 is not in Monitor or Run mode.
Problem
Probable cause
Trigger signals (input signals) are
not received.
The cables are not correctly wired.
The signal line is disconnected.
The status of communications can be checked with the I/O monitor.
The F160 is not in Monitor or Run mode.
Signals cannot be output externally.
The trigger signal has not been input.
The cables are not correctly wired.
The signal line is disconnected.
The status of communications can be checked with the I/O monitor.
The F160 is not in Run mode.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Summary of Contents for F160-2 - 2
Page 6: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 7: ...iv Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 8: ...v Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 11: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 13: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 37: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 55: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 83: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Page 84: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...