Rope Pull Emergency Stop Switch

For the Latest Information

On the Internet: 

www.omron-industrial.com

 or 

www.sti.com

S

a

fety prec

a

ution

s

Oper

a

ting in

s

truction

s

Installation must be in accordance with the following steps and stated
specifications and should be carried out by suitably competent personnel.
Adherence to the recommended maintenance instructions forms part of
the warranty.

!

WARNING

Do not defeat, tamper, remove or bypass this unit.
Severe injury to personnel could result.

W

!

WARNING

1.Installation of all Safety Rope Switch systems must be in accordance

with a risk assessment for the individual application. Installation must
only be carried out by competent personnel and in accordance with
these instructions.

2.Rope support eyebolts must be fitted at 2.5 m. min. to 3 m. max. inter-

vals along all rope lengths between switches. The rope must be
supported no more than 500 mm from the switch eyebolt or Safety
Spring (if used). It is important that this first 500 mm is not used as part
of the active protection coverage.

3.M5 mounting bolts must be used to fix the switches. Tightening torque

for mounting bolts to ensure reliable fixing is 4 Nm. Tightening torque for
the lid screws, conduit entry plugs and cable glands must be 1.5 Nm to
ensure IP seal. Only use correct sizing glands for conduit entry and
cable outside diameter.

4.Tensioning of rope is achieved by use of tensioner / gripper assemblies.

Upon installation, tension to mid-position as indicated by the red arrows
in the viewing window of each switch. Check operation for all switches
and the control circuits by puling the rope at various locations along the
active protection area and resetting each switch by depressing the Blue
Reset button. Ensure each time that the switches latch off and require
manual resetting by depressing the Blue Reset button. Increase the sys-
tem tension further, if required, depending upon the checks along the
active length of coverage. If fitted with a Mushroom type E-Stop button
(Red) then test and reset each switch to ensure function of control cir-
cuits. Typical operational conditions for successful operation of system
is less than 75 N. pulling force and less than 150 mm deflection of rope
between eyebolt supports. If the optional LED is fitted but is not used,
ensure that the conductors remain coiled and tied to the tie hole in the
LED flange.

5.Every week: Check correct operation of system at locations along all

coverage length. Check for nominal tension setting, re-tension rope if
necessary. Every 6 months: Isolate power and remove cover. Check
screw terminal tightness and check for signs of moisture ingress. Never
attempt to repair any switch.

(120VAC)

(120VAC)

Green

Red

(common )

Black

Red

Green

Black

(+24VDC)

(+24VDC)

Optional 24 VDC Indicator Beacon

When +24VDC is applied to the 

red

 wire, the beacon will illuminate red 

and flash.
When +24 VDC is applied to the 

green

 wire, the beacon will illuminate 

green.

Optional 120 VAC Indicator Beacon

When +120VAC is applied to the 

red

 wire, the beacon will illuminate red 

and flash.
When +120 VAC is applied to the 

green

 wire, the beacon will illuminate 

green.

(0 V)

Tension Indicator

Indicator shown with steel rope properly adjusted.

In the intere

s

t of product improvement, 

s

pecific

a

tion

s

 

a

re 

s

ubject to ch

a

nge without notice.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.