background image

100

 Low Voltage Switch Gear 

Appendix

Conversion table

Conversion table for mm²/AWG cable sizes

To convert

Multiply by

Inches to millimeters (mm)

25.4

Millimeters to inches (In.)

0.03937

Feet to meters (m)

0.3048

meters to feet (ft)

3.2808

Yards to meters (m)

0.9144

meters to yards (yd)

1.0936

Miles to kilometers (km)

1.6093

Kilometers to miles (mil.)

0.6214

Square inches to square millimeters (mm

2

)

645.16

Square millimeters to square inches (inch

2

)

0.00155

Square yards to square meters (m

2

)

0.8361

Square meters to square yards (yd

2

)

1.196

Cubic  inches to cubic centimeters (cm

3

)

16.387

Cubic centimeters to cubic inches (inch

3

)

0.06102

Pounds to kilogrammes (kg)

0.4536

Kilogrammes to pounds (lb)

2.2046

Tons (2,240 lb) to kilogrammes (kg)

1,016.05

Kilogrammes to tons (240 lb)

0.0009842

Ounces (avoirdpois) to grammes (g)

28.3495

Grammes to ounces

0.0353

Gallons to litres (l)

4.561

Litres to gallons

0.220

Force N (newtons) to lbft
1 N = 1 kg (mass) accelerated at 1 metre/sec.

0.225

1 Nm = 1 J (joule) to calorie

0.239

Horse-power to kilowatts (kW)

0.7458

Kilowatts to horse-power (h.p.)
1 W (watt) = 1J/s

1.3408

Atmospheres to lb per square inch (lb/inch

2

)

1 bar = 1 kg/cm

2

 = 735.6 mm Hg = 14.2 lb/inch

2

14.68

Conversion table for: 
Centigrade/Fahrenheit

20

0

˚C

˚F

10

20

30

40

50

60

70

80

90

100

110

120

130

140

150

160

170

180

190

200

BP-212

10

0

10

20

30

40

50

60

70

80

90

100

FP-

mm

2

AWG

0.75

18

1.0

17

1.5

16

2.5

13

4.0

12

6.0

10

10.0

8

Summary of Contents for EN 60947 -

Page 1: ...ct ratings switching capacity thermal character istics etc when selecting product type Thermal relay Motor current differs by supplier type number of poles frequency Please confirm operational current...

Page 2: ...posed by sulfication and oxidation on the surface of the contacts Use contactors within the temperature and humidity conditions spec ified in the datasheet to prevent contactors from insulation resis...

Page 3: ...h Type 1 coordination Extract from IEC 947 4 1 The contactor or the starter must not endanger personnel or equipment in the event of a short circuit The contactor or the starter does not need to be su...

Page 4: ...ent of industrial machines DIN VDE 0105 Operation of electrical power installations IEC 536 Protection against electric shock Previous specification New specification Content IEC DIN VDE IEC EN 60947...

Page 5: ...ual resetting of overload releases5 As given by the manufacturer 6 0 1 05 1 6 0 1 05 1 AC 8B Hermetic refrigerant compressor motor control with automatic resetting of overload releases5 As given by th...

Page 6: ...c temperature fluctuation A test cycle consists of 12 hours at 40 2 C with relative humidity of 93 3 and 12 hours at 25 3 C with the relative humidity of at least 95 Ambient temperature Ambient temper...

Page 7: ...perational voItage in accordance with the utilization category For example motor contactor utilization category AC 3 37 kW at 400 V Rated operational voltage Ue IEC 947 1 4 3 1 1 The voItage to which...

Page 8: ...the fuse fulfills its purpose selected to represent a characteristic group of practical applications The speci fied requirements may concern e g the values of making capacities breaking capacities an...

Page 9: ...anipulation inching is thus ruled out Overvoltage category IEC 947 1 2 5 60 Conventional number for prospective overvoltages at the point of installation as might be caused for example by the effect o...

Page 10: ...ociation requires the use of contac tors with interlocked opposing contacts for control systems on power presses in the metal processing industry Positive enforced operation actuation This describes a...

Page 11: ...n 150 volts the con trol voltage applied to input terminals must be at the same potential Low voltage switchgear for auxiliary circuits e g contactor relays control units auxiliary contacts in general...

Page 12: ...USA Valid UL Standards UL 508 Standard for Industrial Control Equipment partly limited Valid UL Standards UL 508 Standard for Industrial Control Equipment unlimited UL 486 Standard for Wire Connectors...

Page 13: ...e basic unit of circuit breakers J7MN 25 conforms with the required air creepage distances According to CSA these terminal blocks can be omitted when the device is used as Combina tion Motor Controlle...

Page 14: ...0 65 65 30 65 50 65 30 50 30 10 65 50 65 50 30 30 65 65 30 65 50 65 30 50 30 12 5 65 50 65 50 30 30 65 65 30 65 50 65 30 50 30 16 65 50 65 50 30 30 65 65 65 50 65 30 20 65 50 65 50 30 30 65 65 65 50 6...

Page 15: ...No Kanada USA Kanada USA Contactors NLDX7 NLDX NLDX8 NLDX2 Accessories NKCR7 NKCR NKCR8 NKCR2 Thermal Overload Relays NKCR7 NKCR Circuit Breakers J7MN as Manual Motor Controller NLRV7 NLRV Circuit Bre...

Page 16: ...contact with live and moving parts by a large body surface such as a hand but not against deliberate access 2L Protected against solid objects great er than 12 5 mm andagainstcontact by standard test...

Page 17: ...5 J7KN 110 M8 Auxiliary conductor J7KN 10 to J7KN 22 M3 5 J7KN 85 to J7KN 110 M3 5 Coil conductor J7KN 10 to J7KN 110 M3 5 Accessories J73KNA M M3 5 J73KN B J73KN C M3 5 Thermal Overload Relays Main c...

Page 18: ...5 0 273 0 206 0 120 0 296 0 210 0 239 0 186 0 330 0 245 0 303 0 226 0 349 0 261 0 318 0 240 0 150 0 300 0 234 0 262 0 204 0 381 0 283 0 349 0 261 0 404 0 301 0 369 0 277 0 185 0 341 0 266 0 296 0 230...

Page 19: ...50 0 41 3 35 1 1 x 185 0 30 8 25 8 2 x 185 0 46 4 39 1 1 x 240 0 34 1 29 0 2 x 240 0 51 2 43 9 1 x 300 0 37 0 32 1 2 x 300 0 56 4 48 7 1 x 400 0 42 0 35 8 2 x 400 0 61 9 54 2 1 x 500 0 45 6 39 6 1 x 6...

Page 20: ...bic inches inch3 0 06102 Pounds to kilogrammes kg 0 4536 Kilogrammes to pounds lb 2 2046 Tons 2 240 lb to kilogrammes kg 1 016 05 Kilogrammes to tons 240 lb 0 0009842 Ounces avoirdpois to grammes g 28...

Page 21: ...0 2 0 8 4 0 2 0 8 4 0 2 0 37 0 72 66 2 0 6 0 4 1 1 4 0 2 1 1 4 0 2 0 55 0 75 69 2 7 10 0 4 1 5 4 0 2 1 5 6 0 4 0 75 0 79 74 3 2 10 0 4 1 9 6 0 4 1 8 6 0 4 1 1 0 81 74 4 6 10 0 6 2 6 6 0 4 2 6 10 0 6...

Page 22: ...6 0 90 2 0 2 0 70 2 0 0 55 0 75 69 1 20 4 0 2 0 90 4 0 2 0 75 0 79 74 1 50 4 0 2 1 10 4 0 2 1 1 0 81 74 2 1 6 0 4 1 5 4 0 2 1 5 0 81 74 2 9 6 0 4 2 1 6 0 4 2 2 0 81 78 4 0 10 0 4 2 9 10 0 4 3 0 0 82 8...