Safety Precautions

Refer to 

Warranty and Limitations of Liability

.

This product is not designed or rated for ensuring 
safety of persons either directly or indirectly.
Do not use it for such purposes.

Do not use the Encoder under ambient conditions that exceed the 
ratings. 

 Mounting

Mount to DIN Track as shown in the following diagram. 

Hook part  (A) at the top of the E63-WF on the DIN Track first and 
then press in on the E63-WF in the direction indicated by (B). 

Removal from DIN Track
Pull down on the track stopper (C) with a flat-blade screwdriver and 
then remove the E63-WF from the DIN Track. When using DIN 
standard 35 track, keep other devices on the track separated from 
the E63-WF by at least 30 mm to facilitate mounting and removal. 

Do not place the connection cable together with high-voltage 
cables. Keep it isolated from other cables whenever possible. 

The response speed of the E63-WF is 120 kHz. Do not allow the 
Rotary Encoder to exceed this speed. 

 Connection

Spurious pulses may be generated when power is turned ON and 
OFF. Wait at least 0.1 s after turning ON the power to the Encoder 
before using the connected device, and stop using the connected 
device at least 0.1 s before turning OFF the power to the Encoder. 
Also, turn ON the power to the load only after turning ON the power 
to the Encoder.

WARNING

Precautions for Correct Use

(B)

(A)

DIN Track (DIN 
standard 35) 
(PFP-100N or 
PFP-100N2)

(C)

30 mm min.

30 mm min.

Track stopper 
(yellow)